Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures (SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성)

  • Lee, Bok-Hee;Baek, Young-Hwan;Oh, Sung-Kyun;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.85-90
    • /
    • 2006
  • This paper presents experimental results relating to the preliminary breakdown characteristics in $SF_6/CO_2$ gas mixtures under a highly non-uniform electric field. The impulse pre-breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both the positive and negative polarities were fundamentally same. The first streamer corona was initiated at the tip of needle electrode, and the leaders developed with a stepwise propagation and bridged the test gap. The pause time of leader pulses in the positive polarity was significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity. The discharge channel path in the positive polarity was zigzag, and the leader channel in the negative polarity was thicker and brighter than that in the positive polarity.

A Study on the HEC(Hybrid ESE-Conductor) Method for Lightning Protection of Buildings (건축물의 낙뢰보호를 위한 HEC(Hybrid ESE-Conductor) 방식에 관한 연구)

  • Kim, Dong-Jin;Kim, Young-Sun;Lee, Ki-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.146-152
    • /
    • 2008
  • The frequency of lightning is increased due to improbable weather condition and global wanning. This phenomenon increases economical damage as well as human damage. Advanced countries like europe and north america have applied the facility standard of lightning by accumulating a store of quantitative data about lightning research. Lightning facility is composed of the lightning accepting part for induction lightning, ground connected electrode which conducts lightning current. The lightning accepting part is composed of normal rod, horizontal conductor, ESE lightning rod. Moreover, lightning accepting part is taken to use by the method of protection. This paper suggests HEC(Hybrid ESE-Conductor) method which mixes horizontal conductor and ESE lightning rod. This is also discovered by experiment that the starting point of corona discharge current is low, so it is efficient for lightning protection comparing with other methods. Moreover, distribution of electric field is analyzed qualitatively by finite element method. It also results in the relation of the starting point of corona discharge current. Corona discharge current makes minute current about some ${\mu}A$ between the electrodes by the strength of electric field. Also it occurs insulation destruction of gas, and it is developed to the shape of streamer by increase of the strength of electric field. We can find that the initial occurrence of streamer and contact probability of lightning can have advantage after researching the starting point of corona discharge current and discharge current of lightning striking point. This research demonstrates that the suggested HEC method is economically competitive as a lightning protection facility, and it takes a capably perfect role.

Chartacteristic of Ozone Genneration by corona Discharge (코로나 방전에 의한 오존 생성 특성)

  • Jeun, Young-Ju;Kang, Chun-Su;Park, Won-Ju;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1375-1377
    • /
    • 1995
  • This paper describes characteristic of ozone Generation by positive streamer corona discharge. Experiments were carried out with needle-plane Electrodes in a pyrex glass tube, in order to in crease the ozone yield. The results of Experiments confirmed needle an gle $45^{\circ}$ Gap spacing 15mm is adaptive Electrode arrangement.

  • PDF

Analysis of Underwater Discharge Characteristics Caused by Impulse Voltages (임펄스전압에 의한 수증방전특성의 분석)

  • Choi, Jong-Hyuk;An, Sang-Duk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.128-133
    • /
    • 2008
  • This paper describes underwater discharge phenomena and breakdown characteristics in case that the standard lightning impulse voltage is injected to the needle and spherical electrodes installed in the hemisphere water tank. The objective of this work is to understand the basic features related to transient ground impedance against lightning surges. The discharge luminous images were observed and the dependence of breakdown voltage on the polarity of applied voltage and water resistivity were investigated. As a consequence, streamer corona is initiated at the tip of needle and spherical electrodes and is propagated toward grounded tank with stepwise extension. The breakdown voltage characteristics measured as a function of water resistivity showed V-shaped curves. Breakdown voltage and time curve of needle electrode is higher than that of spherical electrode.

Ozone Generation of a Small Sawtooth-to-Cylinder Electrode Applied a Pulse Voltage (원톱날 -원통 전극간의 오존 발생특성)

  • 문재덕;김정호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.9
    • /
    • pp.651-654
    • /
    • 1987
  • There are a number of small scale application fields of ozone, such as food conservation and/or storage in refrigerators, containers and storage rooms, deodorization in the production and living areas, protection against biohazards, bleaching of fabrics, etc. For these applications, miniaturization, ozone controllability and costdown of the ozonizer are the most essential points, whereas power efficiency is the most imporant factor in the case of a large scale ozonizer used in various industrial applications. It has been developed a novel sawtooth-to-cylinder type micro-ozonizer meeting above the three points by using a negative pulse corona discharge. As a result of the observations of pulse coronas affecting ozone generation, it is found that the maximum ozone concentration is generated at the pulse streamer coronas in both positive and negative case. The ozone concentration (20ppm/2l/min) generated by the negative pulse corona is about 2 times higher than that of the positive pulse corona, and could be controllable linearly by adjusting the dc input voltage of the [supply-inth ] cinventional small scale ozonizers. As a result, the present ozonizer is also very good to be used as a micro-ozonizer.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

The first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures ($SF_6$ 기체와 $SF_{6}-N_{2}$ 혼합기체의 초기코로나 특성)

  • Lee, B.H,;Kim, J.I.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2002-2004
    • /
    • 2000
  • The discharge processes in electro-negative gases with non-uniform field gape are composed of the formation of pulsed streamer corona, the transition of the streamers into leader step, the temporal development of the leader channel, and the stepped propagation of leader through the gap. In this paper, the first corona inception characteristics in $SF_6$ gas and $SF_{6}-N_{2}$ mixtures, related to the propagation of loader and the space charge effect, were experimentally investigated with positive and negative transient impulse voltages.

  • PDF

Prebreakdown Corona Processes of Point-to-Plane Gap in $SF_{6}$ Gas ($SF_{6}$ 가스중에서 침-평판가극의 전구코로나과정)

  • 이복희;백용현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.140-143
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_{6}$ gas and prebreakdown growth caused by lightning impulse voltages in inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is obserbed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrustion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields ad partial discharges in voids.

  • PDF

Comparison of Coronal Electron Density Distributions from MLSO/MK4 and SOHO/UVCS

  • Lee, Jae-Ok;Lee, Kyung-Sun;Lee, Jin-Yi;Jang, Soojeong;Kim, Rok-Soon;Cho, Kyung-Suk;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.85.2-85.2
    • /
    • 2017
  • The coronal electron density is a fundamental and important physical quantity in solar physics for estimating coronal magnetic fields and analyzing solar radio bursts. To check a validation of coronal electron density distributions (CEDDs) from polarized brightness (pB) measurements with Van de Hulst inversions, we compare CEDDs derived from a polarized brightness (pB) observation [MLSO/MK4 coronameter] and one spectroscopic observation [SOHO/UVCS]. For this, we consider data observed in 2005 with the following conditions: (1) the observation time differences from each other are less than 1 minutes; and (2) O VI doublet (O VI $1031.9{\AA}$ and $1037.6{\AA}$) is well identified. In the pB observation, the CEDDs can be estimated by using Van de Hulst inversion methods. In the spectroscopic observation, we use the ratio of radiative and collisional components of the O VI doublet to estimate the CEDDs. We find that the CEDDs obtained from pB measurements are higher than those based on UVCS observations at the heights between 1.6 and 1.8 Rs (${\times}1.9$ for coronal streamer, 1.2 ~ 1.8 for background corona, and 1.5 for coronal hole), while they are lower than those based on UVCS at the heights between 1.9 and 2.6 Rs (${\times}0.1{\sim}0.6$ for coronal streamer, 0.5 ~ 0.7 for background corona, and 0.6 for coronal hole). The CEDDs of coronal streamers are higher than those of background corona at the between 1.6 and 2.0 Rs: ${\times}1.2{\sim}2.4$ for MK4 and 1.5 ~ 1.9 for UVCS.

  • PDF

Effect of Dielectric Materials on the Silent Discharge Characteristics for Ozone Generation (오존발생을 위한 무성방전특성에 미치는 유전체의 영향)

  • 박명하;곽동주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.628-630
    • /
    • 2000
  • Since the concept for the ozone generation using a nonequilibrium electric discharge techniques had been proposed by Siemens, some experimental and theoretical studies on the ozone generation by streamer corona discharge, surface discharge and silent discharge have been performed. In this paper some results on the discharge characteristics of the silent discharge gap with various dielectric materials were reported. Dielectric materials used in this study were pyrex glass, quartz and glass beefs with diameter of 1 mm.

  • PDF