• Title/Summary/Keyword: stormwater runoff

Search Result 221, Processing Time 0.02 seconds

Urban Renewal with Green on Impermeable Surface (인공지반의 녹화에 의한 도시의 재생)

  • Hajime, Koshimizu
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.17-31
    • /
    • 2004
  • How far of natural regeneration of the city and improvement on the urban environment will be possible in the replanting on the impermeable surface? The replanting of what kind of form will be obtained in order to realize it? The regeneration of the nature is possible, if it can be realized at the thin soil layer in which the result of being equivalent to the natural soil function. Using the light artificial soil with the water retentiveness, it is possible that green on the artificial ground reinforces the green skeleton of the city. The green of artificial ground improves the thermal ambience of the city and demonstrates stormwater runoff depression effect. It is necessary to built the landscape which continues with the surrounding green. Ecologically stabilizing green has the high amenity. The development of replanting technology of the artificial ground which fosters the city culture is desired.

Evaluation on the suspended solids and heavy metals removal mechanisms in bioretention systems

  • Geronimo, Franz Kevin F.;Maniquiz-Redillas, Marla C.;Hong, Jungsun;Kim, Lee-Hyung
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2019
  • Application of bioretention systems in Korea is highly considered due to its minimal space requirements, appropriateness as small landscape areas and good pollutant removal and peak hydraulic flow reduction efficiency. In this study, the efficiency of two lab-scale bioretention types having different physical properties, media configuration and planted with different shrubs and perennials was investigated in reducing heavy metal pollutants in stormwater runoff. Type A bioretention systems were planted with shrubs whereas type B were planted with perennials. Chrysanthemum zawadskii var. latilobum (A-CL) and Aquilegia flabellata var. pumila (A-AP) respectively were planted in each type A bioretention reactors while Rhododendron indicum linnaeus (B-RL) and Spiraea japonica (B-SJ), respectively were planted in each type B bioretention reactors. Results revealed that the four lab-scale bioretention reactors significantly reduced the influent total suspended load by about 89 to 94% (p<0.01). Type B-RL and B-SJ reactors reduced soluble Cr, Cu, Zn, and Pb by 28 to 45% that were 15 to 35% greater than the soluble metal reduction of type A-CL and A-AP reactors, respectively. Among the pollutants, total Cr attained the greatest discharged fraction of 0.52-0.81. Excluding the effect of soil media, total Pb attained the greatest retention fraction in the bioretention systems amounting to 0.15-0.34. Considering the least discharge fraction of heavy metal in the bioretention system, it was observed that the bioretention systems achieved effectual reduction in terms of total Cu, Zn and Pb. These findings were associated with the poor adsorption capacity of the soil used in each bioretention system. The results of this study may be used for estimating the maintenance requirements of bioretention systems.

Evaluation on the adsorption and desorption capabilities of filter media applied to the nonpoint source pollutant management facilities (비점오염 저감시설에 적용되는 여재의 흡착 및 탈착 능력 평가)

  • Moon, Soyeon;Hong, Jungsun;Choi, Jiyeon;Yu, Gigyung;Kim, Lee Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • Urbanization causes many environmental, hydrological and ecological problems such as distortion of the natural water circulation system, increase in nonpoint source pollutants in stormwater runoff, degradation of surface water quality, and damage to the ecosystem. Due to the increase in impervious surface by urbanization, developed countries apply low impact development (LID) techniques as important alternatives to reduce the impacts of urbanization. In Korea, LID techniques were employed since 2012 in order to manage nonpoint source pollutants. LID technology is a technique for removing pollutants using a variety of physical, chemical and biological mechanisms in plants, microorganisms and filter media with the reduced effluence of stormwater runoff by mimicking natural water circulation system. These LID facilities are used in a variety of filter media, but an assessment has not been carried out for the comprehensive comparison evaluation of adsorption and desorption characteristics for the pollutant removal capacity. Therefore, this study was conducted to analyze the adsorption and desorption characteristics of various filter media used in the LID facilities such as sand, gravel, bioceramic, wood chips and bottom ash etc. in reducing heavy metals(Pb, Cu). In this study, the adsorption affinity for Pb in all filter media was higher than Cu. Pseudo second order equation and Langmuir-3 isotherm are more applicable in the adsorption kinetic model and adsorption isotherm model, respectively. As a result of the desorption experiment, the filter media does not exceed KSLT which is the hazardous substance leaching limit, showing the capability of the filter media in LID. The bioceramic and woodchip as filter medias were evaluated and exhibited excellent adsorption capacity for Pb.

Performance Evaluation of Water Circulation Facilities with Infiltration and Retention Functions (침투 및 저류 기능을 가진 물 순환 시설의 효과 평가)

  • Hong, Jung Sun;Maniquiz-Redillas, Marla C.;Kim, Ree Ho;Lee, Seon Ha;Kim, Lee-Hyung
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.305-310
    • /
    • 2015
  • In 2014, the city of Seoul revised the ordinance regarding water-cycle restoration in the Seoul Metropolitan areas by incorporating the 'Low Impact Development (LID)' policy. The new ordinance plan will utilize 630 mm or almost 45 to 50% of annual rainfall until 2050 by means of providing a rainwater management system consisting of infiltration, retention and vegetation. The LID is believed to be the key to achieving the target requirements, specifically in development projects. This research was performed to evaluate the stormwater runoff and pollutant reduction performance of three different LID facilities (water circulation facilities) including an infiltration inlet, bioretention swale, and permeable pavement constructed in Seoul City. Results show that among the water circulation facilities, the permeable pavement achieved the highest runoff reduction as it was able to entirely capture and infiltrate the runoff to the ground. However, in order to attain a long-term performance it is necessary to manage the accumulated sediment and trapped pollutants in the landscape areas through other water circulation techniques such as through soil erosion control. In terms of pollutant reduction capability, the infiltration inlet performed well since it was applied in highly polluted areas. The bioretention facility integrating the physico-chemical and biological mechanisms of soil, microorganisms and plants were able to also achieve a high runoff and pollutant reduction. The water circulation facilities provided not only benefits for water circulation but also various other benefits such as pollutant reduction, ecological restoration, and aesthetic functions.

Runoff Characteristics of Non-Point Sources on the Stormwater (강우에 의한 도로 비점오염원 유출 특성)

  • Kim, Seog-Ku;Kim, Young-Im;Kang, Sung-Won;Yun, Sang-Leen;Kim, So-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.104-110
    • /
    • 2006
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Accordingly, release of contaminants from non-point sources, released with surface runoff of rainwater, is influenced by atmospheric phenomena, geology, and topography. This makes the control of non-point source difficult. Therefore, this study intends to reveal the characteristics of runoff and particle size distribution to observe the fundamental characteristics of runoff. Experiments were carried out at inner road of research center. Average concentration of runoff ranged from 26.8 to 126.4 mg/L for SS and $COD_{Cr}\;15.3{\sim}117.7mg/L,\;TN\;0.07{\sim}5.16mg/L,\;TP\;0.06{\sim}0.49mg/L$ and heavy metals $0.00{\sim}0.29mg/L$. First flush, indicated wash off of pollutant at first rain, was observed for all types of pollutants. Most pollutants revealed a very close correlation with SS ($R^2=0.93{\sim}0.99$). After analyzing characteristics of particle, particle was finer than that from previously examined data.

Hydrologic and Environmental Assessment of an Infiltration Planter for Roof Runoff Use (지붕 빗물이용을 위하여 개발된 침투화분의 환경·수문학적 평가)

  • Moon, So-Yeon;Choi, Ji-Yeon;Hong, Jung-Sun;Yu, Gi-Gyung;Jeon, Je-Chan;Flores, Precious Eureka D.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.325-331
    • /
    • 2015
  • Due to urbanization and increase in impervious area, changes in natural water circulation system have become a cause of groundwater recharge reduction, streamflow depletion and other hydrological problems. Therefore, this study developed the infiltration planter techniques applied in an LID facility treating roof stormwater runoff such as, performance of small decentralized retention and infiltration through the reproduction of natural water circulation system and use of landscape for cleaning water. Assessment of an infiltration planter was performed through rainfall monitoring to analyze the water balance and pollutant removal efficiency. Hydrologic assessment of an infiltration planter, showed a delay in time of effluent for roof runoff for about 3 hours and on average, 79% of facilities had a runoff reduction through retention and infiltration. Based on the analysis, pollutant removal efficiency generated in the catchment area showed an average of 97% for the particulate matter, 94% for the organic matter and 86-96% and 92-93% for the nutrients and heavy metals were treated, respectively. Comparative results with other LID facilities were made. For this study, facilities compared the SA/CA to high pollutant removal efficiency for the determination to of the effectiveness of the facility when applied in an urban area.

A study on the rainfall-runoff reduction efficiency on each design rainfall for the green infrastructure-baesd stormwater management (그린인프라 기반 빗물 관리를 위한 설계강우량별 강우-유출저감 효율성 분석 연구)

  • Kim, Byungsung;Kim, Jaemoon;Lee, Sangjin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.613-621
    • /
    • 2022
  • Due to the global climate change, the rainfall volume and frequency on the Korean Peninsula are predicted to increase at the end of the 21st century. In addition, impervious surface areas have increased due to rapid urbanization which has caused the urban water cycle to deteriorate. Green Infrastructure (GI) researches have been conducted to improve the water cycle soundness; the efficiency of this technique has been verified through various studies. However, there are still no suitable GI design guidelines for this aspect. Therefore, the rainfall scenarios are set up for each percentile (60, 70, 80, 90) based on the volume and frequency analysis using 10-year rainfall data (Busan Meteorological Station). After determining the GI areas for each scenario, the runoff reduction characteristics are analyzed based on Storm Water Management Model (SWMM) 10-year rainfall-runoff-simulations. The total runoff reduction efficiency for each GI areas are computed to have a range of 13.1~52.1%. As a results of the quantitative analysis, the design rainfall for GI is classified into the 80~85 percentile in the study site.

Pollutants Unit Loadings of the Stormwater Runoff in Industrial Complex (강우시 산업단지에서의 유출오염부하량 원단위 산정)

  • Lee, Jun-Ho;Bang, Ki-Woong;Choi, Jong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.355-362
    • /
    • 2000
  • The objective of this paper is to estimate the pollutant load based on event mear concentrations(EMC) in industrial complex. Eight sub-basins in the Chongju industrial complex were selected for sampling and study with different characteristics during the period from June 1997 to August 1998. During the storm events, measured EMC ranges of $BOD_5$, COD, SS, TKN, TP, HEM, $NO_3-N$, $PO_4-P$, Cr, Pb, Cu and Fe in the industrial complex watersheds were 11~176mg/L, 40~502mg/L, 23~633mg/L, 104~20.9mg/L, 0.22~7.51mg/L, 12.7~548.7mg/L, 0.06~2.66mg/L, 0.12~3.39mg/L, 0.01~0.50mg/L. 0.02~0.42mg/L, 0.01~0.15mg/L and 1.29~11.51mg/L respectively. And the calculated annual average pollutant unit loadings of $BOD_5$ COD, SS, TKN, $NO_3-N$, $PO_4-P$, TP, HEM, Cr, Pb, Cu and Fe were 374.4kg/ha/yr 924.1kg/ha/yr, 983.6kg/ha/yr, 48.8kg/ha/yr, 8.1kg/ha/yr, 9.7kg/ha/yr, 17.8kg/ha/yr 943.0kg/ha/yr, 0.7kg/ha/yr, 0.9kg/ha/yr, 0.3kg/ha/yr and 28.9kg/ha/yr, respectively.

  • PDF

Characteristics of Pollutant Washed-off from Highways with Storm Runoff Duration (아스팔트 포장 고속도로의 강우 지속시간별 오염물질 유출 경향)

  • Kim Lee-Hyun;Lee Eun-Ju;Ko Seok-Oh;Kang Hee-Man
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.99-106
    • /
    • 2006
  • During the dry periods, many types of pollutant are accumulating on the paved surface by vehicle activities. Particularly, the highways are stormwater intensive landuses because of high imperviousness and high pollutant mass emissions from vehicles. The accumulated pollutants in highways are washed-off during a rainfall event and are highly contributing on water quality of receiving water bodies. The stormwater runoff from the highways are containing various pollutants such as metals, oil & grease and toxic chemicals originated from vehicles. Therefore, this research is performed to find pollutant characteristics in the magnitude of statistical pollutant concentrations during storm periods. During the monitoring periods, the first-flush phenomenon is visibly occurred on most storm events, which is confirmed from hydro- and pollute-graphs. The 95% confidence intervals of washed-off pollutant concentration are ranged to 154.7-257.1 mg/L for 755,138.9-197.6 mg/L for COD, 3.5-6.4 mg/L for oil & grease, 6.3-9.2 mg/L for TN and 2.3-3.31 mg/L for TP. The first flush effect is mostly occurred within initial 30 min of storm duration.

  • PDF

Determination on the component arrangement of a hybrid rain garden system for effective stormwater runoff treatment (강우유출수 처리를 위한 하이브리드 빗물정원 시스템의 구성요소 배열 연구)

  • Flores, Precious Eureka D.;Geronimo, Franz Kevin F.;Alihan, Jawara Christian P.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.271-278
    • /
    • 2017
  • Low impact development (LID) technology has been recently applied for the treatment of nonpoint source pollutants. Rain garden is one of the widely used LIDs since it utilizes various mechanisms such as biological and physico-chemical treatment to reduce pollutants. However, problem such as clogging has been one of the issues encountered by the rain garden that do not undergo constant maintenance. Therefore, this research was conducted to develop and determine the component arrangement of a rain garden system for a more efficient volume and pollutant reduction. Two hybrid rain garden systems having different characteristics were developed and evaluated to determine the optimum design and arrangement of the system. The results showed that the components arranged in a series manner showed a volume reduction of 93% and a pollutant reduction efficiency of approximately 99%, 93% and 95% was observed for particulates, nutrients and heavy metals, respectively. While when the system is connected in a combined series-parallel, the volume and average pollutant reduction efficiency for the TSS, nutrients and heavy metals are 65%, 94%, 80% and 85%, respectively. Moreover, the component arrangement in the order of sedimentation tank, infiltration tank and plant bed exhibited a high pollutant reduction efficiency compared when the infiltration tank and plant bed were interchanged. The findings of this research will help in the further development and optimization of rain garden systems.