• Title/Summary/Keyword: stormwater pipe systems

Search Result 7, Processing Time 0.026 seconds

Multi-objective optimization of stormwater pipe networks and on-line stormwater treatment devices in an ultra-urban setting

  • Kim, Jin Hwi;Lee, Dong Hoon;Kang, Joo-Hyon
    • Membrane and Water Treatment
    • /
    • v.10 no.1
    • /
    • pp.75-82
    • /
    • 2019
  • In a highly urbanized area, land availability is limited for the installation of space consuming stormwater systems for best management practices (BMPs), leading to the consideration of underground stormwater treatment devices connected to the stormwater pipe system. The configuration of a stormwater pipe network determines the hydrological and pollutant transport characteristics of the stormwater discharged through the pipe network, and thus should be an important design consideration for effective management of stormwater quantity and quality. This article presents a multi-objective optimization approach for designing a stormwater pipe network with on-line stormwater treatment devices to achieve an optimal trade-off between the total installation cost and the annual removal efficiency of total suspended solids (TSS). The Non-dominated Sorted Genetic Algorithm-II (NSGA-II) was adapted to solve the multi-objective optimization problem. The study site used to demonstrate the developed approach was a commercial area that has an existing pipe network with eight outfalls into an adjacent stream in Yongin City, South Korea. The stormwater management model (SWMM) was calibrated based on the data obtained from a subcatchment within the study area and was further used to simulate the flow rates and TSS discharge rates through a given pipe network for the entire study area. In the simulation, an underground stormwater treatment device was assumed to be installed at each outfall and sized proportional to the average flow rate at the outfall. The total installation cost for the pipes and underground devices was estimated based on empirical formulas using the flow rates and TSS discharge rates simulated by the SWMM. In the demonstration example, the installation cost could be reduced by up to 9% while the annual TSS removal efficiency could be increased by 4% compared to the original pipe network configuration. The annual TSS removal efficiency was relatively insensitive to the total installation cost in the Pareto-optimal solutions of the pipe network design. The results suggested that the installation cost of the pipes and stormwater treatment devices can be substantially reduced without significantly compromising the pollutant removal efficiency when the pipe network is optimally designed.

Study on Design Capacity of Stormwater Pipe and Pumping Station considering Peak Rainfall Intensity (첨두강우강도를 고려한 우수관로 및 빗물펌프장의 설계용량 검토)

  • Chung, Gunhui;Sim, Kyu Bum;Kim, Eung Seok
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.9
    • /
    • pp.777-787
    • /
    • 2014
  • Stormwater pipe systems are most commonly used to discharge rainwater from the urban catchment covered by the impervious area. To design stormwater pipe and rainwater pumping station, frequency analysis is implemented using historical rainfall and the design rainfall is timely distributed using theoretical shape such as Huff distribution. This method cannot consider the rainfall intensity variation caused by climate change which is type of uncertainty. Therefore, in this study, runoff from Gasan1 stormwater pumping stations catchment is calculated using design rainfall distributed by the 2nd quartile distribution method and the historical rainfall events. From the analysis, the nodal flooding in the urban catchment is likely caused by the high peak rainfall event rather than the large amount of rainfall. The linear regression analysis is implemented. As a result, when several storms have the same amount of rainfall, the nodal flooding in the stormwater pipe systems could be caused by the high peak of storm events. Since as the storm duration become short, the peak rainfall become high, the nodal flooding likely become severe with the short storm duration. The uncertainty in the peak data of design rainfall is analyzed and this uncertainty has to be consider in the stormwater pipe design process.

Development and Application of the Rainwater Infiltrating Equipment for the Decentralized Stormwater Managements (분산식 우수관리를 위한 침투통 개발 및 적용효과 분석)

  • 성종상;이태구;한영해;김연금;김남희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.2
    • /
    • pp.78-85
    • /
    • 2004
  • To manage rainwater environmentally friendly, it is necessary to let the rainwater be infiltrated naturally and make reservoirs to detain it in the chosen spot. Not only should it be prepared to handle the city flood, but also it be a necessary alternative for establishing the ecological water circular system in cities. Therefore, considering the present rainwater. management system, this study analysed the status of products which can be interchanged from existent systems to rainwater infiltrating systems. In this study, the infiltrating equipment that is applicable to the Korean drainage system was developed. The case was studied out to investigate the effects of infiltrating and the detaining ability of the developed product. The case site, block 6 of Sang-am residence, was selected and analyzed. The amount of infiltration and detention per unit of the introduced facilities, i.e., infiltrating pipes and tanks were calculated. In this research, the amount of each infiltrating tank was revealed to be 1.353 m/hr and the amount of detention as 0.299 m/hr. And the amount of each infiltrating pipe was found to be 0.541 m/hr and the amount of detention was 0.118 m/hr. To examine the effects of the system, the total amount of the outlet before and after installing was compared and calculated. In doing this, a basis for deciding the arrangement and number of tanks and pipes of the infiltrating system was made.

Hydraulic Stability Examination of Rainwater Reservoir Pipe Network System on Various Inflow Conditions (유입량 변화에 따른 도심지 내 우수저류조 관망시스템의 안정성 검토)

  • Yoo, Hyung Ju;Kim, Dong Hyun;Maeng, Seung Jin;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.4
    • /
    • pp.1-13
    • /
    • 2019
  • Recently, as the occurrence frequency of sudden floods due to climate change increased, it is necessary to install the facilities that can cope with the initial stormwater. Most researches have been conducted on the design of facilities applying the Low Impact Development (LID) and the reduction effect on rainfall runoff to examine with 1D or 2D numerical models. However, the studies on the examination about flow characteristics and stability of pipe network systems were relatively insufficient in the literature. In this study, the stability of the pipe network system in rainwater storage tank was examined by using 3D numerical model, FLOW-3D. The changes of velocity and dynamic pressure were examined according to the number of rainwater storage tank and compared with the design criteria to derive the optimal design plan for a rainwater storage tank. As a results of numerical simulation with the design values in the previous study, it was confirmed that the velocity became increased as the number of rainwater storage tank increased. And magnitude of the velocity in pipes was formed within the design criteria. However, the velocity in the additional rainwater storage pipe was about 3.44 m/s exceeding the allowable range of the design criteria, when three or more additional rainwater storage tanks were installed. In the case of turbulence intensity and bottom shear stress, the bottom shear stress was larger than the critical shear stress as the additional rainwater storage was increased. So, the deposition of sediment was unlikely to occur, but it should be considered that the floc was formed by the reduction of the turbulence intensity. In addition, the dynamic pressure was also satisfied with the design criteria when the results were compared with the allowable internal pressure of the pipes generally used in the design of rainwater storage tank. Based on these results, it was suitable to install up to two additional rainwater storage tanks because the drainage becomes well when increasing of the number of storage tank and the velocity in the pipe becomes faster to be vulnerable to damage the pipe. However, this study has a assumption about the specifications of the rainwater storage tanks and the inflow of stormwater and has a limitation such that deriving the suitable rainwater storage tank design by simply adding the storage tank. Therefore, the various storage tank types and stormwater inflow scenarios will be asked to derive more efficient design plans in the future.

Comparison of Optimization Techniques in Cost Design of Stormwater Drainage Systems (우수관망 시스템 설계에 있어서의 최적화기법의 비교)

  • Kim, Myoung-Su;Lee, Chang-Yong;Kim, Tae-Jin;Lee, Jung-Ho;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.2 s.21
    • /
    • pp.51-60
    • /
    • 2006
  • The objective of this research is to develop a least cost system design method for branched storm sewer systems while satisfying all the design constraints using heuristic techniques such as genetic algorithm and harmony search. Two sewer system models have been developed in this study. The SEWERGA and SEWERHS both determine the optimal discrete pipe installation depths as decision variables. Two models also determine the optimal diameter of sewer pipes using the discrete installation depths of the pipes while satisfying the discharge and velocity requirement constraints at each pipe. Two models are applied to the example that was originally solved by Mays and Yen (1975) using their dynamic programming(DP). The optimal costs obtained from SEWERGA and SEWERHS are about 4% lower than that of the DP approach.

Cost-Effectiveness Analysis of Low-Impact Development Facilities to Improve Hydrologic Cycle and Water Quality in Urban Watershed (도시유역의 물순환 및 수질 개선을 위한 저영향개발 시설의 비용 효율 분석)

  • Choi, Jeonghyeon;Kim, Kyungmin;Sim, Inkyeong;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.3
    • /
    • pp.206-219
    • /
    • 2020
  • As urbanization and impermeable areas have increased, stormwater and non-point pollutants entering the stream have increased. Additionally, in the case of the old town comprising a combined sewer pipe system, there is a problem of stream water pollution caused by the combined sewer overflow. To resolve this problem, many cities globally are pursuing an environmentally friendly low impact development strategy that can infiltrate, evaporate, and store rainwater. This study analyzed the expected effects and efficiency when the LID facility was installed as a measure to improve hydrologic cycle and water quality in the Oncheon stream in Busan. The EPA-SWMM, previously calibrated for hydrological and water quality parameters, was used, and standard parameters of the LID facilities supported by the EPA-SWMM were set. Benchmarking the green infrastructure plan in New York City, USA, has created various installation scenarios for the LID facilities in the Oncheon stream drainage area. The installation and maintenance cost of the LID facility for scenarios were estimated, and the effect of each LID facility was analyzed through a long-term EPA-SWMM simulation. Among the applied LID facilities, the infiltration trench showed the best effect, and the bio-retention cell and permeable pavement system followed. Conversely, in terms of cost-efficiency, the permeable pavement systems showed the best efficiency, followed by the infiltration trenches and bio-retention cells.

Development of Urban Inundation Analysis Model Using Dual-Drainage Concept (Dual-Drainage 개념에 의한 도시침수해석모형의 개발)

  • Lee, Chang Hee;Han, Kun Yeun;Noh, Joon Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4B
    • /
    • pp.379-387
    • /
    • 2006
  • An urban inundation model coupling an one-dimensional stormwater model, SWMM(Storm Water Management Model), and a two-dimensional inundation model was developed to simulate inundation caused by the surcharge of storm sewers in urban areas. The limitation of this model which can not simulate the interaction between drainage systems and surcharged flow was resolved by developing Dual-Drainage inundation analysis model which was based upon hydraulic flow routing procedures for surface flow and pipe flow. The Dual-Drainage inundation analysis model can simulate the effect of complex storm drainage system. The developed model was applied to Dorim, catchment. The computed inundated depth and area have good agreement with the observed data during the flood events. The developed model can help the decision support system of flood control authority for redesigning and constructing flood prevention structures and making the potential inundation zone, and establishing flood-mitigation measures.