• Title/Summary/Keyword: stored fuel

Search Result 123, Processing Time 0.03 seconds

Safety Review of Severe Accident Senario for Wet Spent Fuel Storage Facility (사용후핵연료 습식저장 시설의 중대사고 안전성 검토)

  • Shin, Tae-Myung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.4
    • /
    • pp.231-236
    • /
    • 2011
  • When the Fukushima nuclear power plant accident occurred in March of 2011, a hydrogen explosion in the reactor building at the 4th unit of Fukushima plants led to a big surprise because the full core of the unit 4 reactor had been moved and stored underwater at the spent nuclear fuel storage pool for periodic maintenance. It was because the possible criticality in the fuel storage pool by coolant loss may yield more severe situation than the similar accident happened inside the reactor vessel. Fortunately, it was assured to be evitable to an anxious situation by a look of water filled in the storage pool later. In the paper, the safety state of the spent fuel storage pool and rack structures of the domestic nuclear plants would be roughly reviewed and compared with the Fukushima plant case by engineering viewpoint of potential severe accidents.

Thermal Analysis on the Spent Fuel Shipping Cask for a PWR Fuel Assembly (PWR 사용후 핵연료 수송용기에 대한 열해석)

  • Hee Yung Kang;Eun Ho Kwack;Byung Jin Son
    • Nuclear Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.248-255
    • /
    • 1983
  • The thermal analysis on the spent fuel shipping cask for a PWR fuel assembly is performed. Under the normal and fire-accident conditions the temperature distribution through a multilayer cask calculated in compliance with 10 CFR Part 71. A KNU 5&6 spent fuel assembly is assumed to be the decay heat source, which has the maximum discharge turnup of 45, 000MWD/MTU and has been stored in the spent fuel storage pool for 300 days. As a result of thermal analysis, the maximum cladding temperature in case of dry cavity under fire-accident conditions is calculated to be 455$^{\circ}C$. This value is much less than the limiting value specified in 10 CFR Part 50.46. It indicates that no fuel rod cladding rupture could occur under fire-accident conditions. It was also found that no melting of lead would take place in the major shield region.

  • PDF

A software tool for integrated risk assessment of spent fuel transportation and storage

  • Yun, Mirae;Christian, Robby;Kim, Bo Gyung;Almomani, Belal;Ham, Jaehyun;Lee, Sanghoon;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.721-733
    • /
    • 2017
  • When temporary spent fuel storage pools at nuclear power plants reach their capacity limit, the spent fuel must be moved to an alternative storage facility. However, radioactive materials must be handled and stored carefully to avoid severe consequences to the environment. In this study, the risks of three potential accident scenarios (i.e., maritime transportation, an aircraft crashing into an interim storage facility, and on-site transportation) associated with the spent fuel transportation process were analyzed using a probabilistic approach. For each scenario, the probabilities and the consequences were calculated separately to assess the risks: the probabilities were calculated using existing data and statistical models, and the consequences were calculated using computation models. Risk assessment software was developed to conveniently integrate the three scenarios. The risks were analyzed using the developed software according to the shipment route, building characteristics, and spent fuel handling environment. As a result of the risk analysis with varying accident conditions, transportation and storage strategies with relatively low risk were developed for regulators and licensees. The focus of this study was the risk assessment methodology; however, the applied model and input data have some uncertainties. Further research to reduce these uncertainties will improve the accuracy of this model.

Design of the Fuel Cell Powered Line-Interactive UPS System (연료전지 시스템을 이용한 Line-Interactive 방식의 무정전 전원 공급 장치의 설계)

  • Choi, Woo-Jin;Jeon, Hee-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.205-212
    • /
    • 2004
  • In this paper the design of a 1-[KVA] fuel cell powered line-interactive UPS system employing modular (fuel cell & DC/DC converter) blocks is proposed. The proposed system employs the two fuel cell modules along with suitable DC/DC converters and these modules share the DC-Link of the DC/AC inverter. A supercapacitor module is also employed to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor. The energy stored in the supercapacitor can also be utilized to handle the overload conditions for a short time period. Due to the absence of batteries, the system satisfies the demand for an environmentally friendly and dean source of the energy. A complete design example illustrating the amount of hydrogen storage required for 1hr power outage, and sizing of supercacpacitor for transient load demand is presented for a 1-[KVA] UPS.

Criticality effect according to axial burnup profiles in PWR burnup credit analysis

  • Kim, Kiyoung;Hong, Junhee
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1708-1714
    • /
    • 2019
  • The purpose of the critical evaluation of the spent fuel pool (SFP) is to verify that the maximum effective multiplication factor ($K_{eff}$) is less than the critical safety limit at 100% stored condition of the spent fuel with the maximum reactivity. At nuclear power plants, the storage standard of spent fuel, ie, the loading curve, is established to prevent criticality from being generated in SFP. Here, the loading curve refers to a graph showing the minimum discharged burnup versus the initial enrichment of spent fuel. Recently, US NRC proposed the new critical safety assessment guideline (DSS-ISG-2010-01, Revision 0) of PWR SFPs and most of utilities in US is following it. Of course, the licensed criterion of the maximum effective multiplication factor of SFP remains unchanged and it should be less than 0.95 from the 95% probability and the 95% confidence level. However, the new guideline is including the new evaluation methodologies like the application of the axial burnup profile, the validation of depletion and criticality code, and trend analysis. Among the new evaluation methodologies, the most important factor that affects $K_{eff}$ is the axial burnup profile of spent fuel. US NRC recommends to consider the axial burnup profiles presented in NUREG-6801 in criticality analysis. In this paper, criticality effect was evaluated considering three profiles, respectively: i) Axial burnup profiles presented in NUREG-6801. ii) Representative PWR axial burnup profile. iii) Uniform axial burnup profile. As the result, the case applying the axial burnup profiles presented in NUREG-6801 showed the highest $K_{eff}$ among three cases. Therefore, we need to introduce a new methodology because it can be issued if the axial burnup profiles presented in NUREG/CR-6801 are applied to the domestic nuclear power plants without any other consideration.

Preliminary Design of the Forced Gas Drying System for Spent Nuclear Fuel Dry Storage (사용후핵연료 건식저장을 위한 기체강제순환 건조장치 예비설계)

  • Chae, Gyung-sun;Shin, Kyung-wook;Park, Byeong-mok;Han, Jae-hyun;Lee, Geon-hui;Park, Jae-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • For dry storage of the spent nuclear fuel (SNF) stored in the storage pool of a nuclear power plant, essentially all moisture must be removed to prevent corrosion of the assembly and canister internals and/or degradation of fuel cladding integrity after SNF canister loading operation. R&D work is now in progress on a forced gas drying system that can be used to remove residual water in canisters. In this work, preliminary design is performed to manufacture the forced gas drying system. This process includes a case study of dry methods for canister moisture removal, relative codes and standards, confirmation of adequate dryness, needs analysis at plant sites, and characteristics of SNF stored in pools. Through this preliminary design work, we obtained a conceptual flow diagram and preliminary P&ID of the forced gas drying system. The results of this study can be used to determine details of the design to manufacture the forced gas drying system.

Performance Simulation of a Turboprop Engine for Basic Trainer

  • Kong, Changduk;Ki, Jayoung;Chung, Sukchoo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.839-850
    • /
    • 2002
  • A performance simulation program for the turboprop engine (PT6A-62), which is the power plant of the first Korean indigenous basic trainer KT-1, was developed for performance prediction, development of an EHMS (Engine Health Monitoring System) and the flight simulator. Characteristics of components including compressors, turbines, power turbines and the constant speed propeller were required for the steady state and transient performance analysis with on and off design point analysis. In most cases, these were substituted for what scaled from similar engine components'characteristics with the scaling law. The developed program was evaluated with the performance data provided by the engine manufacturer and with analysis results of GASTURB program, which is well known for the performance simulation of gas turbines. Performance parameters such as mass flow rate, compressor pressure ratio, fuel flow rate, specific fuel consumption and turbine inlet temperature were discussed to evaluate validity of the developed program at various cases. The first case was the sea level static standard condition and other cases were considered with various altitudes, flight velocities and part loads with the range between idle and 105% rotational speed of the gas generator. In the transient analysis, the Continuity of Mass Flow Method was utilized under the condition that mass stored between components is ignored and the flow compatibility is satisfied, and the Modified Euler Method was used for integration of the surplus torque. The transient performance analysis for various fuel schedules was performed. When the fuel step increase was considered, the overshoot of the turbine inlet temperature occurred. However, in case of ramp increase of the fuel longer than step increase of the fuel, the overshoot of the turbine inlet temperature was effectively reduced.

On-Site Transport and Storage of Spent Nuclear Fuel at Kori NPP by KN-12 Transport Cask (KN-12 운반용기를 이용한 고리 사용후핵연료 소내수송.저장)

  • Chung, Sung-Hwan;Baeg, Chang-Yeal;Choi, Byung-Il;Yang, Ke-Hyung;Lee, Dae-Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.51-58
    • /
    • 2006
  • Since 2002, more than 400 PWR spent nuclear fuel assemblies have been transported and stored on-site using transport casks in order to secure the storage capacity of PWR spent nuclear fuel of Kori nuclear power plant. The complete on-site transport system, which includes KN-12 transport casks, the related equipment and transport vehicles, had been developed and provided. KN-12 transport casks were designed, fabricated and licensed in accordance with Korean and IAEA's transport regulations, and the related equipment was also provided in accordance with the related regulations. The on-site transport and storage operation using two KN-12 casks and the related equipment has been conducted, and the strict Quality Control and Radiation Safety Management through the whole process has been carried out so as to achieve the required safety and reliability of the on-site transport of spent nuclear fuel.

  • PDF

GUI-based integrated monitoring system for small sized fuel cell ship (소형 연료전지 선박을 위한 GUI 기반의 통합 모니터링 시스템)

  • Lee, Hunseok;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2235-2242
    • /
    • 2016
  • The electric power system based on fuel cell is applied in various forms to the ship and offshore plants. In particular, a research on the hybrid power system of the fuel cell combined with battery in connection topology has been researched actively. Fuel cell-based hybrid ship has not been carried out research, it is not carried out research in the integrated monitoring system. In this paper, we developed an integrated monitoring system to increase the convenience and stability for the hybrid fuel-cell ship operator. Research into integrated monitoring system based on GUI (Graphic User Interface), in consideration of the stability of the user convenience and ship operations, and developed communication and hardwired signal with the main equipment of the ship, to see in realtime state of the ship. The collected ship operation data is stored and it can be seen after the ship operating.

A Study about Impact of Battery SOC on Fuel Economy of Conventional Diesel Vehicle (배터리 충전상태가 경유자동차 에너지소비효율에 미치는 영향 연구)

  • Kim, Sungwoo;Kim, Kiho;Ha, Jonghan;Kwon, Seokjoo;Seo, Youngho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.4
    • /
    • pp.480-486
    • /
    • 2016
  • Manufacturers have been applying several technologies that can improve the fuel economy of their cars. The regulated voltage control(RVC) system, is one of those technologies being used in passenger cars. In RVC, the voltage of an alternator is controlled depending on the electrical load demand or battery SOC, although each manufacturer differs from another in terms of detail. RVC can reduce the load of an alternator by consuming the stored energy of a battery and simultaneously generate energy. In this paper, a diesel passenger car equipped with an RVC system was tested under FTP-75 and HWFET modes to evaluate fuel economy as their initial battery SOC(100, 90, 80 and 60 %). The test results showed that the initial SOC affects fuel economy only under the FTP-75 mode. FTP-75 fuel economy of the 60% SOC was 13.2 % lower than the 100 % SOC. Also, the simultaneous consumption of the two energy sources did not appear in 60 % SOC.