• Title/Summary/Keyword: storage method

Search Result 4,843, Processing Time 0.032 seconds

Transient Response Analysis of Cylindrical Liquid Fuel-Storage Tank subject to Initial Acceleration (원통형 액체 연료탱크의 초기 가속에 따른 과도응답 해석)

  • Lee, S.Y.;Joo, Y.S.;Kim, K.W.;Cho, J.R.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.475-480
    • /
    • 2000
  • The transient dynamic-response analysis of fuel-storage tanks of flying vehicles accelerating in the vertical direction is achieved with finite element method. A fuel-storage tank is a representative example of the fluid-structure interaction problem, in which structure and fluid media interact strongly. For the accurate analysis of this complicated fluid-structure system, we employed ALE(arbitrary Lagrangian-Eulerian) coupling method. Two types of fuel-storage tanks, one with two baffles and the other without baffle, are considered to examine the effect of baffles. The fuel-storage tank with baffles shows more uniform hydrodynamic pressure distribution, resulting effective stress in structural region and faster convergence from transient to steady states. MSC/Dytran, a commercial FEM software for the 3D coupled dynamic analysis, is used for this analysis.

  • PDF

Effect of Nickel Oxide on Hydrogen Storage Behaviors of Mesoporous SBA-15

  • Lee, Seul-Yi;Park, Soo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.231-231
    • /
    • 2009
  • In this work, we prepared the Ni-loaded porous SBA-15 (SBA-15) by a depositionprecipitation (D-P) method, in order to enhance the hydrogen storage capacity. The structure and morphology of the Ni/SBA-15 were characterized by X-ray diffraction (XRD) and field emission transmission electron microscopy (FE-TEM). The results showed that, at the Ni loading used at the DP times in the range of 0-120 min, SBA-15 preserved the well-ordered hexagonal porous arrangement. The textural properties of the Ni/SBA-15 were analyzed using N2 adsorption isotherms at 77 K. Specific surface area and mesopore volume of the samples were determined from the Brunauer-Emmett-Teller (BET) equation and Barrett-Joiner-Halenda (BJH) method, respectively. The hydrogen storage capacity of the Ni/SBA-15 was evaluated at 298 K/10 MPa. The hydrogen storage capacity of the Ni/SBA-15 was increased in accordance with Ni content. Consequently, it was found that the presence of Ni on mesoporous SBA-15 created hydrogen-favorable sites which enhanced the hydrogen storage capacity by spillover effect.

  • PDF

Verification Test of Failover Recovery Technique based on Software-Defined RAID (Software-Defined RAID 기반 장애복구 기법과 실증 테스트)

  • Cha, ByungRae;Choi, MyeongSoo;Park, Sun;Kim, JongWon
    • Smart Media Journal
    • /
    • v.5 no.1
    • /
    • pp.69-77
    • /
    • 2016
  • This paper proposes a software defined storaging method to converge the network virtualization technique and the RAID of distributed storage environment. The proposed method designs software based storage which it apply a flexible control and maintenance of storages. In addition, the method overcomes the restricted of physical storage capacity and cut costs of data recovery. The proposed failover recovery technique based on Software-Defined RAID has been tested the substantial verification and the performance using public AWS and Google Storage.

Comparison of Two Experimental Approaches to Test Temporal Storability of Reduced Sulfur Compounds in Whole Sampling Method (환원황화합물에 대한 용기채취법의 비교 연구)

  • Jo, Sang-Hee;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.3
    • /
    • pp.306-315
    • /
    • 2012
  • In this study, storage stability of reduced sulfur compounds ($H_2S$, $CH_3SH$, DMS, $CS_2$, and DMDS) and $SO_2$ in sampling bags was investigated in terms of two contrasting storage approaches between forward (F) and reverse (R) direction. The samples for the F method were prepared at the same time and analyzed sequentially through time. In contrast, those of reverse (R) method were prepared sequentially in advance and analyzed all at once upon the preparation of the last sample. In addition, relative performance between two different bag materials (PVF and PEA) was also assessed by using 100 ppb standard. The response factors (RF) of gaseous RSC samples were determined by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server (AS)/thermal desorber (TD) system at storage intervals of 0, 1, and 3 days. There is no statistical difference in all RSCs between two storage methods. However, the results of relative recovery indicated 2.58~12.8% differences in compound type between the two storage methods. Moreover, loss rates and storage stability of $H_2S$ and $SO_2$ were considerably affected by bag materials than any other variables. Therefore, some considerations about storage methods (or bag material types) for sulfur compounds are needed if stored by sampling bag method.

A Study on the Storage Life Estimation Method for Applying Gamma Process Model to Accelerated Life Test Data (가속수명시험 자료에 감마 과정 모델을 적용한 저장 수명 예측 기법 연구)

  • Park, Sungho;Kim, Jaehoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.3
    • /
    • pp.30-36
    • /
    • 2013
  • This paper presents a method to estimate a storage life for loss of stabilizer content as storage periods using accelerated life test data. The estimate of storage life based on deterministic accelerated life test and degradation data cannot describe a condition distribution and storage life distribution. Previously, the method to show the condition distribution and storage life distribution by using gamma process has been studied. But it has limitation because it is impossible to collect the deterioration data at initial production phase. The estimated storage life presented by this study shows the similar value to previous studies and the method can describe the condition distribution and storage life distribution. So, the estimation method studied in this paper can be used for a life cycle management about deterioration of propellant for propulsion unit or components of missile, too.

Unit Commitment Considering Variable Power of Hydro and Pumped Storage Hydro Units (수력 및 앙수발전기의 가변출력운전을 고려한 기동전지 계획에 관한 연구)

  • 송길영;이범;김용하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.3
    • /
    • pp.351-362
    • /
    • 1994
  • This paper presents a new method for solving a long term unit commitment problem including hydro and pumped storage hydro units in a large scale power system. The proposed method makes it possible to get variable power of hydro and pumpde storage hydro units and results in the better unit commitment with good convergency. Moreover this paper proposes an unit commitment algorithm to consider variable power of these units effectively by Lagrangian Relaxation method. By applying the proposed method to the test system and the real system, it is verified the usefulness of this method.

Compensation Method of Mechanical Error for Micro Holographic Storage (마이크로 홀로그래픽 저장장치의 기계적 에러 보상기법)

  • Min, Cheol-Ki;Jeon, Sung-Bin;Cho, Chang-Hyun;Kim, Do-Hyung;Park, No-Cheol;Yang, Hyun-Seok;Park, Kyoung-Su;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2012
  • In this paper, we experimentally investigated compensation method of the mechanical errors for the micro holographic storage. The aim of this research was overcome of disc tilt and spherical aberration problems. The proposed method was performed by using glass plate and zoom optics.

Real-time Beam Exposure Time Control of Holographic Data Storage (홀로그래픽 저장장치의 실시간 광 노출시간 제어)

  • Han, Cho-Lok;Kim, Nak-Yeong;Song, Hee-Chan;Lim, Sung-Yong;Park, No-Cheol;Park, Young-Pil;Yang, Hyun-Seok
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • Holographic data storage system is one of next generation high density optical memories. Thereby storing multiple data pages using multiplexing method in one spot, we can achieve high store density and fast access time. However, for uniform writing, we must control exposure time properly by the change of writing material characteristics. Many studies have been investigated about exposure time scheduling. However, once it is decided, we cannot change the scheduled time. Therefore, it is hard to obtain uniform data intensity. In this study, we propose exposure time control method using additional red beam as the monitoring signal. Through reconstructed red beam intensity in real time, we can adjust exposure time by the writing condition change. We construct compensation method mathematically and verify the feasibility of proposed method through the experiments.

Polarization Multiplexing Method for Micro Holographic Storage (마이크로홀로그래픽 스토로지를 위한 편광다중화기법)

  • Min, Cheol-Ki;Kim, Do-Hyung;Park, No-Cheol;Yang, Hyun-Seok;Park, Kyoung-Su;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.2
    • /
    • pp.52-56
    • /
    • 2010
  • In this paper, we investigate the polarization multiplexing for micro holographic storage. The proposed multiplexing method is performed by using crystal media that use photorefractive materials such as Fe-doped $LiNbO_3$. We discuss the feasibility of fast recording, high capacity and transfer rate for polarization multiplexing method. Finally, we experimentally verify the proposed method using polarization selectivity.

Experimental Study on the Rapid Cooling System by Refrigerant Storage Method (냉매 저장방식에 의한 쾌속 냉각장치에 대한 실험적 연구)

  • 장기태;고준석;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.937-942
    • /
    • 2003
  • In the present study, low-temperature low-pressure refrigerant storage method is proposed to achieve higher cooling capacity during a short period of time than that of a compressor in steady operation. Experimental apparatus was designed and set up to analyze the performance of the new-conceptual cooling system. Two reservoirs for sequential storage of refrigerant were used in the cooling system. Several on/off solenoid valves were installed for control of refrigerant flow. From the experimental results, the initial rapid cooling by low temperature low-pressure refrigerant storage method was ascertained for successful operation. This rapid cooling methodology shall be useful for other low-capacity refrigeration system.