• Title/Summary/Keyword: storage facility

Search Result 616, Processing Time 0.026 seconds

A Study on the Tool-Trace of Wooden Storage Facilities in Sabi Baekje through the Reproduction Experiments: Focusing on the Adze, Chisel, and Saw

  • Heesoo SONG;Soochul KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.3
    • /
    • pp.276-288
    • /
    • 2024
  • This study was conducted to reproduce the woodworking process of Baekje wooden storage facilities. Green timber of Quercus spp. was processed using ancient woodworking tools, and the tool-trace formed in this process were compared with the tool-trace of actual excavated artifacts. In the tool-trace analysis, the length and shape of the tool-trace were objectively recorded using a 3D Scan, and that were difficult to confirm with photograph were confirmed through stereoscopic microscope. As a result, there were two types of adze's tool-trace. One of them is minute straight Blade-top trace line when trimming the wood surface and the other is Plucked trace that appear when strongly chop at the wood. When a chisel bat was not used, a long and wide continuous shape blade trace was produced. And when the chisel head was struck with the chisel bat, a straight blade-top trace was regularly observed. Saw-trace was identified in several layers with fine straight stripes. Through this, it was found that the tool-trace of the woodworking tools, which is estimated to have been used in each process, and the tool-trace remaining in the Baekje wooden storage facility coincide.

Multi-body dynamics model for spent nuclear fuel transportation system under normal transport test conditions

  • Seongji Han;Gil-Eon Jeong;Hyeonbeen Lee;Woo-Seok Choi;Jin-Gyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4125-4133
    • /
    • 2023
  • The transportation of spent nuclear fuel is an important process that involves road and sea transport from an interim storage facility to storage and final disposal sites. As spent nuclear fuel poses a significant risk, carefully evaluating its vibration and shock characteristics under normal transport conditions is essential. In this regard, full-scale multi-modal transport tests (MMTT) have been conducted domestically and internationally. In this paper, we discuss the process of developing a multi-body dynamics (MBD) model to analytically simulate conditions that cannot be considered in tests. The MBD model is based on the KORAD-21 transportation system was validated using the Korean MMTT results from 2020 to 2021. This paper summarizes the details of the development and verification of the MBD model for the KORAD-21 transportation system under normal transport test conditions. This approach can be applicable to various transportation scenarios and systems, and the results of this study will help to ensure that nuclear fuel transportation is conducted safely and effectively.

Feature and Operation on Correlation for Royal (State operation) Storage of Baekjae (백제 왕실(국영) 창고시설의 특징과 운영)

  • So, Jae Yun
    • Korean Journal of Heritage: History & Science
    • /
    • v.45 no.4
    • /
    • pp.22-37
    • /
    • 2012
  • Storage facility of the pre-historic Korea is classified into the subterranean, ground and overground types. The rectangular-shaped subterranean Storage facilities have been identified in the Pungnaptoseong, the Gong mountain fortress site and the Gwanbukri site. Feature no. 196 at Gyeongdang District in Pungnaptoseong yielded a large quantity of glazed potteries, and a wooden storage at the Gwanbukri site contained a large amount of fruit seeds. These storage facilities might be functioned as the warehouse for the highest group rather than the storage for the emergency such as war and flooding and stipend of government officials. This article subdivided into "state storage" on the concept of the former that "royal storage" on the concept of the latter. If it look on the state storage at large, this include the royal storage too. But it subdivided to help article understand because Baekjae changed from state storage to royal storage by change and specialization of system after 4th. The reason why the diversification of storage pits was closely related to the unification of local polities and the concentration of political power in the state-level. Therefore, it might reflect the political circumstances the ruling elites attempted to heighten their authority in terms of the organizing tax collecting system. And divided the time of storage is confirmed separative storage pits in the suburbs of capital city. There is hight probability of top local polities or nation that have possessional a role. This is to cover on frequent war in the Three States. On the other hand, state storage is located around ancent road that linked castle gate that is divided into center and periphery depending on function and position of storage. Center is located royal storage focusing in the presumed royal palace that periphery is located state storage to provide service to the public. It is presumed that located with the government office.

Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines (병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발)

  • 이정숙;곽동경;강영재
    • Korean journal of food and cookery science
    • /
    • v.19 no.4
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

A Development of Condition Evaluation Standard Considering Structural Characteristic for Members of LNG Outer Storage Tanks (LNG 외조 저장탱크의 구조적 특성을 고려한 상태평가 기준 개발)

  • Choi, Kyoung-Jae;Seo, Chang-Joo;Kim, Young-Gu;Jo, Young-Do;Kim, Jung-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.64-69
    • /
    • 2017
  • South Korea is the world's second-largest importer of LNG and possess about 70 tanks which are in operation by 2017. Thirty years as the design warranty period have exceeded since LNG storage tanks as the core facility of LNG industry were constructed in 1986. The LNG storage tank is under precision safety diagnosis from 2014 due to urban gas business act amendment. There is no criteria of condition evaluation for outer tank of LNG storage tank at the time of precision safety diagnosis. Through analysis of structural characteristic of LNG storage tank and civil structure condition evaluation standards, the criteria of condition evaluation for main members was developed. The criteria of objective condition evaluation can improve safety and reliability of LNG storage tank and suggest matenance criteria.

Stability Analysis of the CNG Storage Cavern in Accordance with Design Parameters (설계변수에 따른 압축천연가스 저장 공동의 거동 분석)

  • Park, Yeon-Jun;Moon, Hyung-Suk;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.192-202
    • /
    • 2013
  • The domestic demand of natural gas has increased continuously due to the sudden rise of oil price and regulations on greenhouse gas to global warming. In order to improve the supply security of natural gas market in Korea, the agreement on supply of pipeline natural gas (PNG) in Russia was signed between Gazprom and Korea Gas Corporation in 2008. If the supply plan of Russian natural gas is realized, underground storage facilities would be required in order to balance supply and demand of natural gas because the gas demand is concentrated in the winter. This study investigated the safety of the storage facility in quantitative way considering several design parameters such as gas pressure, depth of the storage cavern, rock condition and in-situ horizontal stress ratio. Two dimensional stress analyses were conducted using axi- symmetry condition to examine the behavior of cavern depending upon suggested design parameters. Results showed that the factor of safety, defined as the ratio of 'shear strength'/'shear stress', was largely affected by the depth, rock class and gas pressure but was insensitive to the coefficient of lateral pressure(Ko).

KSLV 추진기관 종합시험설비 피해 사고 예측 모델 해석

  • Lee, Jung-Ho;Kang, Sun-Il;Yu, Byung-Il;Kim, Yong-Wook;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.163-170
    • /
    • 2005
  • According to the KSLV program of KARI, it is planed to develop various launch vehicle and satellite 10 years hereafter. Large-scale test facilities, such as ReTF and PTA-II, are needed to fulfill this launch vehicle/satellite development project. The authors intend to arrange and describe various indexes that are needed in test facility design, construction and operation process. This technical paper is describing model analysis of damage prediction of accident in KSLV Integrated Propulsion System Test Facility based on propellant storage quantity and layout. In addition, the result can be used to produce safer design of test facility.

  • PDF

Internal Flow Aerodynamic Test of a Mach 5 Scramjet Engine (마하 5 스크램젯 엔진의 내부 유동 공력 시험)

  • Yang, In-Young;Lee, Yang-Ji;Kim, Young-Moon;Lee, Kyung-Jae;Kang, Sang-Hoon;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.584-587
    • /
    • 2011
  • An internal flow aerodynamic test was performed for a Mach 5 scramjet engine. The test was done without fuel injection, as a preliminary test for the combustion test. Test engine is an engineering model with intake cross-section of $70mm{\times}200mm$ and total length of 1.7m. Test facility is a blowdown-type, high enthalpy, hypersonic facility. 19 pressures were measured through the holes on the model surface along the engine internal flow passage. It was found that the facility start is possible, and also supersonic flow is maintained inside the engine.

  • PDF

A Study on the International Accreditation Standard and Unit Spatial Organization of Public School in Korea (국내공립학교의 국제인증기준과 단위공간구성에 관한 연구)

  • Lee, Eul-Gyu;Jeon, You-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.1
    • /
    • pp.13-22
    • /
    • 2016
  • Recently, Korea has been established and operated International Schools manifesting to improve the nation's capacity of the foreign languages skill and to cultivate internationally trained professional manpower. In order to achieve the vision of a world-class educational organization, it has to be designed for the facility standards to meet the international accreditation standards. Therefore, the main purpose of this study is to research about basic resources through comparison of facility conditions between public schools in Korea and international accredited schools. By comparing those two different plan drawings are found the following things. First, Schools which established with International Accreditation Standard are prepared detailed criteria for the facility, Furthermore information about the furnishings included, in addition to specific equipments for classes are stated to be prepared. Secondly, it is more effective when special classrooms such as music and science are equipped with various spatial elements, enough educational equipment storage, teacher's study rooms, practical training rooms and student's activity rooms to support various teaching programs and learning efficiently. Lastly, there was a clear tendency that not only hardware but also software standards for the audiovisual room and library have been more enhanced to enable multidisciplinary educational approaches with the recent education training trend.

Analysis on the heat-resisting method of the electrolytic metal reduction reactor in the test facility for the spent fuel waste (사용후핵연료 시험시설에서 전기 금속 전환반응기의 내열 방안 분석)

  • 김영환;윤지섭;정재후;홍동희;박기용;진재현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.776-779
    • /
    • 2003
  • To reduce the storage space of spent fuel used at the atomic power plants in the over the world, the uranium elements contained in the spent fuel is being extracted and effectively stored. For this, the spent fuel are oxidized and deoxidized. In this study, it is produced the heat-resisting methods about the spent fuel management technology research and test facility for the spent fuel waste for spent fuel minimized. The first considered processes in the facility are the electrolytic metal reduction reactor process. Since the electrolytic metal reduction reactor is operated at the high temperature range, we have to consider the heat-resisting methods for the devices. For the heat-resisting methods, we have searched and analyzed technical reference for the heat-resisting methods. We have calculated thermal stress and strain of each devices by the commercial analysis software, ANSYS. D.S. It is experimented for inspecting confidence rate of analysis results. By using the results, we have analyzed the problems of parts and determined the heat-resisting material, commercial parts, and the size of parts and O-ring. Based on these results, it is produced the heat-resisting methods of magnesia filter, cathode, and reactor for the electrolytic metal reduction reactor.

  • PDF