• Title/Summary/Keyword: storage facilities

Search Result 795, Processing Time 0.028 seconds

Planning for Safety Control on LPG Distribution Depot (LPG 판매업소의 위험성 제어계획)

  • 노삼규;전성우;강태희;서영민
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.21-30
    • /
    • 1998
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation to the neighbouring structure and human activity required to be estimated to find the gap between existing controls on such storage. PHAST and IAEA manual for risk rankings and assessment had been applied to get the required safety distance for neighbouring facilities, Japanese legal control for such facilities were also investigated. To this context the issues on LPG vessel storage required additional safety distance between existing blast wave barrier structure and safety separation distances.

  • PDF

Safety Evaluation Method for Ground Ammunition and Explosive Storage Facilities due to Underground Tunnel Blast (지하시설 굴착공사에 따른 탄약저장시설 안전성 평가방법 연구)

  • Park, Sangwoo;Kim, Kuk-Joo;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.4
    • /
    • pp.331-339
    • /
    • 2019
  • Recently, expansion of urban and social infrastructures is planned to go through the transfer of military facilities or crossing the infrastructures via underground tunnels. However, when crossing facilities such as ammunition and explosive storages, a high level of safety assessment is required to prevent an accidental explosion of ground ammunition. In this study, a case study was conducted to evaluate the effect of blasting for the construction of tunnel on the ground ammunition facilities. The design section of Sinansan train operated by the Korea Railroad Authority with agreement of the Ministry of National Defense was selected. For the purpose of this study, the vibration velocity due to explosion was predicted by using GTS-NX, a numerical analysis program. Through literature review, it was confirmed that the vibration velocity of 0.2cm/sec can be a safety evaluation standard. These safety evaluation indicators and procedures used in this study can be utilized as an index of safety evaluation in the planning of social infrastructures that cross the ammunition facilities in the future.

Technological Review of Icing & Frozen Industry in Korea ("우리나라 제빙 냉동업의 기술적 리뷰")

  • Park Hi-Yul
    • Journal of the Korean Professional Engineers Association
    • /
    • v.12 no.3
    • /
    • pp.18-22
    • /
    • 1979
  • "In summary, the freezing facilitty manufacturing industry has a bright prospects for further development. So followings are recommended: 1) The import restriction policy should be continued to expand the demand for the 10callT manufactured facilities, 2) Training of local people and import of advanced technologies should be encouraged 3) The capacities of the local manufacturing industry should be expanded to meet the: increasing demand for the facilities, 4) Further incentives should be affered to the freezing & cold storage sector for the repla¬cement of the worm-out facilities 5) The marketing channel of marine products should be reorganized into ""cold-chain system"" by providing a legislative supports."

  • PDF

산업부문 에너지 관리기술

  • 김상현;전원표;김동국
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2000.11a
    • /
    • pp.161-175
    • /
    • 2000
  • This study includes the fundamental planning of the sectoral management technology in energy distribution system so that the industry itself would be willing to participate for the effective energy conservation in its own sector. Furthermore guidlines for the effective energy management techniques have been presented by first analyzing the energy consumption structures, the energy loss problems, the energy conservation status and the technology demands, and second classifying, according to the energy distribution system, the energy source management, the energy generation & conversion facilities, the energy transportation & storage facilities, the energy consumming facilities and the waste energy management, etc. in the industrial sector.

  • PDF

Study on the Prevention of Corrosion Damage for Underground Fuel Stroage Tank(1) (Corrosion Damage under the Sea Sand) (지하연료저장탱크의 부식손상 방지에 관한 연구(1) (바다모래에서 부식 손상))

  • 임우조;서동철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • As consumption rate of energy increase rapidly, the facilities of fuel storage tank become large size. Almost all of the industry or public facilities storing fuel in underground fuel storage tank is manufactured by steel materials. Thus, this fuel storage tank made of steel materials is damaged by stray-current corrosion, it become destruction. If fuel storage tank is destructed, petroleum, oil and gas are leaked. So it bring about environmental pollution, energy loss, fire and explosion. Therefor, in this study, for study on the prevention of corrosion damage in underground fuel storage tank, it were investigated by corrosion and stray-current corrosion for SS 400 in dry sea sand and wet sea sand along to specific resistance. The main results obtained are as follows : As specific resistance decrease in wet sea sand, corrosion rate per year increase linearly, in case of back fill up wet sea sand in underground fuel storage tank, if the water is flow into dry sea sand, corrosion tendency of underground fuel storage tank is supposed sensitive.

  • PDF

Feasibility Study of Underground LNG Storage System in Rock Cavern (LNG 지하공동 비축시스템의 타당성분석)

  • Chung, So-Keul;Han, Kong-Chang;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.296-306
    • /
    • 2006
  • It is difficult to solve problems regarding the adjustment on demand and supply of LNG due to seasonal variations of domestic demand of LNG, a discordance among import pattern and limits of storage facilities and so on. Also, there may be instability in LNG supply due to chances of accidents at LNG producing areas. Therefore, it is very important to secure large LNG storage facilities and to stabilize LNG supply management on a long term basis. The objective of this study is to examine the real-scale applicability of a lined underground rock storage system, which have been verified by a successful operation of the Daejeon LNG pilot plant. The new technology has many advantages of better economy, safety and environment protection, for above-ground and in-ground storage systems. The results of this study may promote the first ever real scale underground LNG storage system in a rock cavern.

Geo-Environmental Site Investigation for Underground Oil Storage facilities and Landfill Using the Envi-Cone Penetrometer System (환경콘 관입시스템을 이용한 유류저장소 및 폐기물매립지 지중환경특성 조사)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.33-36
    • /
    • 2000
  • The purpose of this study investigated underground oil storage(USTs) and Landfill using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground.

  • PDF

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Evaluation of Short-Term Exposure Levels on Ammonia and Hydrogen Sulfide During Manure-Handling Processes at Livestock Farms

  • Park, Jihoon;Kang, Taesun;Heo, Yong;Lee, Kiyoung;Kim, Kyungran;Lee, Kyungsuk;Yoon, Chungsik
    • Safety and Health at Work
    • /
    • v.11 no.1
    • /
    • pp.109-117
    • /
    • 2020
  • Background: Ammonia and hydrogen sulfide are harmful gases generated during aerobic/anaerobic bacterial decomposition of livestock manure. We evaluated ammonia and hydrogen sulfide concentrations generated from workplaces at livestock farms and determined environmental factors influencing the gas concentrations. Methods: Five commercial swine farms and five poultry farms were selected for monitoring. Real-time monitors were used to measure the ammonia and hydrogen sulfide concentrations and environmental conditions during the manure-handling processes. Monitoring was conducted in the manure storage facility and composting facility. Information on the farm conditions was also collected through interview and walk-through survey. Results: The ammonia concentrations were significantly higher at the swine composting facilities (9.5-43.2 ppm) than at other manure-handling facilities at the swine and poultry farms, and high concentrations of hydrogen sulfide were identified during the manure agitation and mixing process at the swine manure storage facilities (6.9-19.5 ppm). At the poultry manure-handling facilities, the ammonia concentration was higher during the manure-handling processes (2.6-57.9 ppm), and very low hydrogen sulfide concentrations (0-3.4 ppm) were detected. The air temperature and relative humidity, volume of the facility, duration of manure storage, and the number of animals influenced the gas concentrations. Conclusion: A high level of hazardous gases was generated during manure handling, and some levels increased up to risk levels that can threaten workers' health and safety. Some of the farm operational factors were also found to influence the gas levels. By controlling and improving these factors, it would be possible to protect workers' safety and health from occupational risks.

Records Management Business Analysis of Certified Electronic Document Center as the 'External Electronic Records Storage Facilities' ('외부전자기록물저장시설'로서 공인전자문서센터의 업무 분석)

  • Lee, Kyungnam
    • The Korean Journal of Archival Studies
    • /
    • no.47
    • /
    • pp.227-254
    • /
    • 2016
  • The purpose of this study is to review whether Certified Electronic Document Center can perform electronic records preservation work as 'external electronic records storage facilities'. It began with addressing the current state of Certified Electronic Document Center. And then reviewed the key concepts of archival science in archival science literature and the meaning of electronic records preservation. The results of the review pointed out that these concepts are confused depending on each designated community's interests while the revision of the Archives Law. And finally we inspected whether Certified Electronic Document Center has an ability to perform the electronic records preservation work. For this, we compared and analyzed Archives Law, national archives' standards and regulations related to Certified Electronic Document Center. As a result, we may confirm that the current Certified Electronic Document Center did not have the capability for records management.