• 제목/요약/키워드: storage facilities

검색결과 817건 처리시간 0.025초

Inequalities in External-Cause Mortality in 2018 across Industries in Republic of Korea

  • Lim, Jiyoung;Ko, Kwon;Lee, Kyung Eun;Park, Jae Bum;Lee, Seungho;Jeong, Inchul
    • Safety and Health at Work
    • /
    • 제13권1호
    • /
    • pp.117-125
    • /
    • 2022
  • Background: External-cause mortality is an important public health issue worldwide. Considering its significance to workers' health and inequalities across industries, we aimed to describe the state of external-cause mortality and investigate its difference by industry in Republic of Korea based on data for 2018. Methods: Data obtained from the Statistics Korea and Korean Employment Information System were used. External causes of death were divided into three categories (suicide, transport accident, and others), and death occurred during employment period or within 90 days after unemployment was regarded as workers' death. We calculated age- and sex-standardized mortalities per 100,000, standardized mortality ratios (SMRs) compared to the general population and total workers, and mortality rate ratios (RRs) across industries using information and communication as a reference. Correlation analyses between income, education, and mortality were conducted. Results: Age- and sex-standardized external-cause mortality per 100,000 in all workers was 29.4 (suicide: 16.2, transport accident: 6.6, others: 6.6). Compared to the general population, all external-cause and suicide SMRs were significantly lower; however, there was no significant difference in transport accidents. When compared to total workers, wholesale, transportation, and business facilities management showed higher SMR for suicide, and agriculture, forestry, and fishing, mining and quarrying, construction, transportation and storage, and public administration and defense showed higher SMR for transport accidents. A moderate to strong negative correlation was observed between education level and mortality (both age- and sex-standardized mortality rates and SMR compared to the general population). Conclusion: Inequalities in external-cause mortalities from suicide, transport accidents, and other causes were found. For reducing the differences, improved policies are needed for industries with higher mortalities.

목포항 물류시스템의 분석에 관한 연구 (On the Analysis of Physical Distribution System in Mokpo Port)

  • 이철영;남만우
    • 한국항만학회지
    • /
    • 제10권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Rapid change in the technological environment of marine transportation and the development of the ocean shipping industry have fostered a revolution in the port system. This in turn has caused major changes in the function and use of port in Korea. Aside from this, Mokpo Port, however continues to decline, because the existing port facilities and related subsystem are already obsolete with no chance of regaining operational effectiveness and treatment for proper implementation. Although a few studies have been done on the Mokpo Port, has not been found, any reseach for the analytical approach to the transportation system of it. This paper aims to make an extensive analysis of the physical distribution system in Mokpo Port focusing on the coordination of subsystems such as navigational aids system. The base of introduced simulation tool here is the queueing theory. The overall findings are as follows: 1. Among those vessels called at Mokpo Port in 1994, 556 ships(2,736,669 G/T) are oceangoing while 8155 ships(2,587,217 G/T) are domestic. The average size of oceangoing vessels is 4,922,1 G/T, and the domestic is 317,8 G/T. The average arrival interval and service time of the domestic vessels are 6.0 hours and 24.1 hours respectively marking the berth occupation rate over 100%. Those for oceangoing vessels are 34.5 hours, 120.0 hours and 37.2%. In order to maintainin the berth occupation rate to 70% the capacity considering the 1994 of domestic piers must be extended to 145% and oceangoing vessels must be increased to 165%. 2. The capacity of approaching channel is enough to handle the total traffic volume of 3. Tugs are sufficiently being provided to handle all ships requiring their services 4. The capacity of storage and inland transportation systems are sufficient to handle the throughput and the yard stroage utilization rate of No.1 - No.5 is 4.5% and No.6 is 30% of 1993's. 5. The utilization rate of LLC(Level Looping Crane) and PNT(PNeumaTic) are 2.7% and 18.8%, respectively.

  • PDF

빗물받이 효율 개선을 위한 저류-침투시설의 효과 분석 (Flood Reducition Effect Analysis of Storage and Infiltration Facilities of Rainwater Drainage Efficiency improvement)

  • 박종표;원창연;정창삼
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.68-68
    • /
    • 2023
  • 호우로 인한 도시 지역의 침수는 빗물받이의 능력 부족, 우수관로 용량 부족 등 다양한 요인에 의하여 발생한다. 구체적으로 빗물받이 능력 부족으로 인한 침수는 노면에 떨어진 우수가 빗물받이로 유입하지 못하고 지표면을 유하하여 저지대에 빗물이 모여 발생하게 되며 우수관로의 용량부족은 설계 강우 이상의 호우가 발생하거나 하류 배수위 영향으로 인하여 우수관로 내 만관이 발생하여 맨홀 월류로 인하여 침수가 발생하게 된다. 도시지역의 침수를 경감하기 위해서는 구조적, 비구조적인 대책을 마련할 수 있으며 본 연구에서는 국부적인 노면 침수가 발생하는 주요 도로 주변부의 침수발생을 효율적으로 제어하기 위한 구조적 대책 중 하나인 UHPC 저류침투시설 도입에 따른 홍수저감 효과를 수리수문학적 분석하는 방법을 개발하였다. 분석 절차는 ① 대상지역 현황 분석을 위한 관망도, 수치지형도, 토지피복도, 토양도 등 관련 자료의 조사 ② 침수 발생 현황 및 시설물 설치에 따른 효과분석을 위한 강우분석 ③ 주요 호우 시 대상지역 침수발생 현황 분석 ④ 저수지 홍수추적 기법을 활용한 저류침투시설 도입효과 계산 ⑤ 주요 호우별 홍수조절효과 분석결과를 기초로 저류침투시설 도입에 따른 침수 저감 효과를 2차원으로 검토의 5개 단계로 이루어진다. 노면을 따라서 유하 또는 맨홀 월류에 의해 저류 침투시설로 유입하는 우수의 홍수조절 효과 분석은 연구에서 개발한 스프레드시트 기반 저수지 홍수추적 기법을 활용하여 분석하였으며 강우-유출량 중 10 %가 시설물로 유입하는 가정 조건하에 시설물로 유입하는 우수의 저류-침투-방류를 동시에 고려하여 계산하였다. 다만, 저류침투시설로 유입하는 노면 유출수의 정량적 수치는 자연적 요인 및 다양한 제약 조건에 따라 큰 차이가 있을 수 있으며 불확실성이 높으므로 노면 유출수의 저류침투시설 유입량의 추가적인 연구가 필요하다.

  • PDF

고속 발사체와 충돌한 시멘트복합체의 보강재 종류에 따른 내충격 특성 연구 (Impact Resistance Characteristics of Cementitious Composites Subjected to High-velocity Projectiles with Reinforcement Types)

  • 석원균;김영선;이예찬;남정수;김규용
    • 한국건축시공학회지
    • /
    • 제23권3호
    • /
    • pp.261-272
    • /
    • 2023
  • 본 연구는 현재 늘어나고 있는 수소 충전소 및 ESS 시설 등에서 예상치 못한 사고로 발생할 수 있는 폭발 위험과 이로 인한 구조물 방호 기술의 중요성에 초점을 맞추고 있다. 시멘트 복합체의 보강 방법에 따른 내충격 특성을 평가하여 구조물의 방호 설계를 위한 기초 데이터를 제시하였다. 실험결과 가장 기본적 구조재료인 철근콘크리트는 내충격 성능에 미치는 보강효과가 무근 콘크리트에 비해 약 20% 향상되는 것으로 나타났으며, 고속충격과 같은 빠른 하중에 대해서는 국부적 보강보다는 섬유와 같이 매트릭스 전체를 보강하는 방법이 효과적인 것으로 확인되었다.

의료기관 특수실 감염관리를 위한 비접촉 출입인증 관리 시스템 (Contactless Access Certification Management System for Infection Control in Special Rooms in Medical Institutions)

  • 이효승;최우진
    • 한국전자통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.387-392
    • /
    • 2022
  • 2019년 의료법 시행규칙에 따라 감염관리가 필요한 시설(수술실, 분만실, 중환자실 등)에 대하여 출입기준을 준수함은 물론이며 출입자에 대한 입실, 퇴실, 연락처 등의 출입 사실에 대한 기록을 남겨 1년간 보존하도록 의료기관의 특수 실에 대한 출입기준이 개정되었다. 하지만, 현재까지도 이러한 내용에 대하여 수기로 작성을 하거나 오기 등의 이유로 불편함이 지속하고 있다. 이러한 이유로 본 연구에서는 IoT 장치와 UWB 기술을 활용하여 인가된 사용자에 대한 자동 개폐 및 출입 기록 저장 기능을 제공하는 시스템을 설계 구현하였고, 이를 통해 출입자의 편의와 시스템화된 출입통제가 가능할 수 있을 것으로 기대한다.

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • 웰빙융합연구
    • /
    • 제5권4호
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

지하구조물건설 현장지원 통합관리시스템 도입을 위한 경제적 타당성 분석 (Economic Feasibility Analysis for Introducing Integrated Management System for Supporting Underground Construction)

  • 백현기;장용구;서종원
    • 대한토목학회논문집
    • /
    • 제30권5D호
    • /
    • pp.513-522
    • /
    • 2010
  • 도시인구 과밀현상, 지상도로교통망 포화 등의 문제를 해결하기 위한 효율적 토지활용방안으로 지하도로교통망, 복합단지, 저장시설 등 다양한 형태의 지하구조물 건설이 증가하고 있다. 본 연구에서는 지하구조물 시공 시 열악한 환경에 적합한 작업자의 3차원 위치와 통신 연락을 위한 현장지원 통합관리시스템 개발의 경제적 타당성 분석을 수행하였다. 본 분석을 위해 터널 및 지하철건설을 대상으로 현장조사 및 작업자 설문조사를 수행하여 현행 지하구조물 건설 현장관리 프로세스 분석, 문제점 파악 및 시스템 도입을 통해 발생할 것으로 예상되는 편익의 정량적 도출을 실시하였으며, 본 시스템 도입으로 발생할 것으로 예상되는 사고감소, 현장관리비 절감, 생산성 향상을 편익으로 추정하고 경제성 분석기법인 편익/비용비(B/C), 순 현재가치(NPV), 내부수익률(IRR)을 활용하여 시스템 도입의 경제적 타당성 분석을 수행하였다. 분석 결과, 편익/비용비는 1.79로 도출되었으며, 순현재가치와 내부수익률은 각 103,423,797원, 47.01%로 산출되어, 본 시스템 도입의 경제성을 확보할 수 있는 것으로 분석되었으며, 변수들의 불확실성을 고려하여 민감도 분석을 실시하였다.

적외선 카메라를 활용한 급이 유무에 따른 어류 활동성 분석 (Analysis of Fish Activity in Relation to Feeding Events Using Infrared Cameras)

  • 노태경;하상현;김기환;강영진;정석찬
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제32권4호
    • /
    • pp.137-147
    • /
    • 2023
  • Purpose The domestic aquaculture industry in South Korea utilizes both formulated feeds and live feeds for the cultivation of fish. While nutrient-rich live feeds, particularly using fry, have been preferred since the past, formulated feeds are gaining attention due to issues related to overfishing and environmental concerns. Formulated feeds are advantageous for storage and supply but require a sustained feeding regimen due to the comparatively slower growth rate compared to live feeds. As the aging population in rural areas leads to a shortage of labor, automated feeding systems are increasingly being adopted in aquaculture facilities. To enhance the efficiency of such systems, it is crucial to quantitatively analyze the behavioral changes in fish based on the presence or absence of feed. Design/methodology/approach In the study, RGB cameras and infrared cameras were used to analyze fish activity according to feeding, and an outline extraction algorithm was applied to analyze the differences resulting from this. Findings Unlike RGB cameras, infrared cameras are more suitable for analyzing underwater fish activity as they convert objects' thermal energy into images. It was observed that Canny, Sobel, and Prewitt filters showed the most distinct identification of fish activity.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

전기차 화재 실험 및 대응방안에 관한 연구 (An Experiment Study on Electric Vehicle Fire and Fire Response Procedures)

  • 남기훈;이준식
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-70
    • /
    • 2024
  • Lithium-ion batteries (LIB) are widely used in various sectors, such as transportation (e.g., electric vehicles (EV)) and energy (e.g., energy storage facilities) due to their high energy density, broad operating temperature (-20 ℃ ~ 60 ℃), and high capacities. LIBs are powerful but fragile on external factors, including pressure, physical damage, overheating, and overcharging, that cause thermal runaway causing fires and explosions. During a LIB fire, a large amount of oxygen is generated from the decomposition of ionogenic materials. A water fire extinguisher that helps with cooling and suffocating must be essentially required at the same time. In fact, however, it is difficult to suppress LIB fires in the case of EVs because a LIB is installed with a battery pack housing that interrupts direct extinguishing by water. Thus, this study aims to investigate effective fire extinguishing measurements for LIB fires by using an EV. Relevant documents, including research articles and reports, were reviewed to identify effective ways of LIBs fire extinguishing. A real-scale fire experiment generating thermal runaway was carried out to figure out the combustion characteristics of EVs. This study revealed that the most effective fire extinguishing measurements for LIB fires are applying fire blankets and water tanks. However, there is still a lack of adequate regulation and guidelines for LIB fire extinguishment. Taking this into account, developing functional fire extinguishment measurements and available regulatory instruments is an urgent issue to secure the safety of firefighters and citizens.