• Title/Summary/Keyword: storage facilities

Search Result 795, Processing Time 0.036 seconds

Study on Design Method of Tunnel-type Ammunition Storage Chamber (터널형 탄약고의 격실 설계 방법에 대한 연구)

  • Park, Sangwoo;Baek, Jangwoon;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, the demand for underground-type ammunition storage facilities has increased. Comparing with a ground-type ammunition storage facility, the underground-type ammunition storage facility can decrease the standard of safety distance because fragment and blast wave can be locked in the rock formation. However, the absence of a design method on the underground-type ammunition storage chamber became a major setback for the construction promotion. In this study, the process for designing an overall configuration of the underground-type ammunition storage facility was provided. First, the determination method for configuration and number of the chamber was developed by performing the ammunition storage simulation. Then, a tunnel (i.e., transfer channel for vehicles) and designed chambers can be arranged on the basis of safety distance standard. The safety distance standard also should be considered for determining the location and the size of entrances because of the blast wave and fragment effect at the entrances when an explosion is generated inside a chamber. In addition, considerations on the design for the waterproof and the drainage of subsurface water were analyzed through construction cases. Finally, an example of designing underground-type ammunition storage chambers was provided in order to verify the developed design process.

An Empirical Study on Clothing Distribution Center to Improve Storage Efficiency : Especially on Hanger Rack Storage According to Distance between Columns (의류 물류센터 보관효율 향상을 위한 실증적 연구 : 행거 랙 보관과 건물기둥 간격을 중심으로)

  • Nam, Hee Dae
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.75-80
    • /
    • 2019
  • Sales of the Korean clothing industry grew to 16.9 percent on-year in 2010, but the growth rate dropped to 3 percent from 2011 to 2016 and the overall market began to slump to 1.1.6 percent in 2017. The competitiveness of clothing companies is also a major sector in logistics capability, and the average logistics cost of domestic clothing companies is 8.3 percent of sales in 2011, higher than the average 8 percent of domestic industries, and 36.4 percent of the total storage cost in 2011, higher than the 28.8 percent share of the total storage cost of domestic companies. As domestic production conditions such as wage hikes and labor disputes worsened in the 1990s, production facilities were rapidly moved overseas, which led many clothing companies to have no production facilities or a minimal production base in Korea and focus on marketing and design capabilities. The total storage capacity and storage efficiency of the logistics center became very important as the products were changed to the form of mass warehousing and small-volume forwarding. Research shows that building column spacing, a model of this research, can affect the amount of hanger rack storage empirically, so for sustainable growth of clothing companies, it is necessary to improve competitiveness in the logistics market by reducing costs and improving efficiency to overcome difficulties in corporate management. Because logistics costs are 8.3 percent and operating profit to sales ratio is 2 percent, it is expected that operating profit will increase by 41.5 percent if logistics costs are reduced by 10 percent. If 10% of storage cost is saved based on storage cost, operating profit is expected to increase by 15% To strengthen the competitiveness of the clothing industry, a reduction in logistics costs is essential. Therefore, the purpose of this study is to provide hints that logistics experts can have empirically small amounts in reducing storage costs through column spacing adjustment of logistics centers that have not been dealt with statistically until now, and to contribute to the continued growth of clothing companies and the development of the domestic logistics industry.

An Experimental Study on Characteristics of Heat Flow in the Cylindrical Storage Tank with Ice Ball (Ice Ball을 내장(內裝)한 빙축열조내(氷蓄熱槽內)의 열유동(熱流動) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Jang, Y.G.;Lee, W.S.;Pak, J.W.
    • Solar Energy
    • /
    • v.18 no.1
    • /
    • pp.99-109
    • /
    • 1998
  • The study on ice thermal storage system is to improve total system performance in actual air-conditioning facilities. To attain the high efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therfore the process flow must be piston flow in thermal storage tank. Ice packing factor is better on condition that the inflowing temperature is low, the flow direction in the thermal storage is upward and the cylindericalthermal storage type is used. This result shows that the cylinderical ice storage tank has better storage capacity than the rectangular type in case of the same porocity.

  • PDF

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System (저온 잠열 축열조내의 열유동 특성에 관한 연구)

  • Lee, W.S.;Park, J.W.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

The information system concept for thermal monitoring of a spent nuclear fuel storage container

  • Svitlana Alyokhina
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3898-3906
    • /
    • 2023
  • The paper notes that the most common way of handling spent nuclear fuel (SNF) of power reactors is its temporary long-term dry storage. At the same time, the operation of the dry spent fuel storage facilities almost never use the modern capabilities of information systems in safety control and collecting information for the next studies under implementation of aging management programs. The author proposes a structure of an information system that can be implemented in a dry spent fuel storage facility with ventilated storage containers. To control the thermal component of spent fuel storage safety, a database structure has been developed, which contains 5 tables. An algorithm for monitoring the thermal state of spent fuel was created for the proposed information system, which is based on the comparison of measured and forecast values of the safety criterion, in which the level of heating the ventilation air temperature was chosen. Predictive values of the safety criterion are obtained on the basis of previously published studies. The proposed algorithm is an implementation of the information function of the system. The proposed information system can be used for effective thermal monitoring and collecting information for the next studies under the implementation of aging management programs for spent fuel storage equipment, permanent control of spent fuel storage safety, staff training, etc.

Commercial Utilization of Irradiation for the preservation of Foods and its Hygienic Effects (방사선조사에 의한 식품저장의 산업화 필요성과 위생적 효과)

  • 조한옥
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.107-113
    • /
    • 1986
  • It is estimated that the loss of Korean agricultural and fishery products during the storage period is usually more than 20%, and it is difficult to increase agricultural products by a 10% annual rate directly. Therefore, development of food preservation techniques has now become a most important atternative for the indirect increase of such products and for its senitary distribution. Changes eating habits and improved living conditions have accelerated the demand for convenience food production and for this reason it is essential that raw materials at stable, resonable prices and hygienic quality be available the year round. At the end of 1980, the Korean government conceded th economical feasibility of the storage of foods by irradiation and a procedure for preserving food by irradiation on a batch scale was successfully developed by KAERI in 1982. Based on the research results accomplished by the KAERI and on the recommendation on wholesomeness of irradiated food by Joint Committee of FAO/IAEA/WHO in 1980, the approval of wholesomeness of irradiated food was declared by presidential decree in June 1985 and the procedure of permission for individual items is in progress. Korean private firms (Ryung Young Co.) which was technically assisted by KAERI for five years have taken mush interest in the establishment of such facilities in Korea, therefore Ryung Young Co. had proposed for the construction of 500 Kci Co-60 irradiator to the Ministry of Science and Technology in July 1984. The permission of construction has approved by government in May 1985. The commercial irradiator will be constructed as one of the most modernized facilities until May 1987 and that facilities will contribute the propagation of commercial storage of foods and its hygienic quality.

  • PDF

Measurement of Thermal Expansion Coefficient of Rock using Strain Gauge (스트레인 게이지를 이용한 암석의 열팽창계수 측정)

  • Park, Chan;Kim, Hyung-Mok;Synn, Joong-Ho;Park, Yeon-Jun;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.17 no.6
    • /
    • pp.475-483
    • /
    • 2007
  • With increasing demand for LNG as energy resources and need for $CO_2$ sequestration as greenhouse gas, more storage facilities are required in Korea. Due to the recent acute safety concerns and land shortage, storage facilities tend to be located underground. In design and construction of underground storage for low and high temperature materials, besides their mechanical characteristics, the thermal characteristics of rock under temperature variation should be understood. In this study, laboratory experiments for the measurement of the thermal expansion coefficient of rock were performed using strain gauge in consideration of the particle size of mineral and experiment temperature range. Experiment results show that thermal expansion coefficient decreased as the temperature decreases. In addition, linear thermal expansion coefficient was developed for typical Korean rocks such as granite. The results of this study can be utilized for the evaluation of thermal propagation in rock mass and the thermo-mechanical stability of underground facilities.

DEVELOPMENT of CONTINUOUS GRAIN DRYER

  • Kim, Y.H.;Cho, Y.K.;Cho, K.H.;Keum, D.H.;Han, C.S.;Han, J.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.396-404
    • /
    • 2000
  • Post harvest processes for rice include drying, storage and processing. Drying has a great effect on the quality of the grain. The existing rice centers are with the ill equipped, especially with drying and storage facilities. The rice harvesting has bully mechanized, a large volume of rice with high moisture content are taken to the rice processing complex(RPC). Three, the need for drying and storage facilities becomes more urgent. At present the daily drying capacity of RPC can't exceed over 40~50 M/T. Therefore new technology and facilities for a high quality and main efficient drying should be introduced one such technology is the continuous flow drying system. This research, aims to test performance efficiency the mixed continuous flow grain dryer was whose daily drying capacity is 100 M/T. The results of the performance tests of the dryer are shown as follows; (1) The temperature distribution of the drying modules were measured by a temperature recorder. The fifth module showed the highest value, followed by the seventh and the third. (2) When the intake air temperature was $55^{circ}C$, the drying rates were 1.7 and 2.6%, wb/pass in the exhaust temperatures of 20 and $22^{circ}C$. And when the intake air temperature was $60^{circ}C$, the drying rates were 1.7 and 2.3%, wb/pass in the exhaust temperatures of 22 and $25^{circ}C$. (3) The average increased rate of cracked grains after the drying process was 0.7% which is below the tolerance limit (2.0%) of the continuous grain dryer.

  • PDF

Prevention of Soil Contamination from Underground Storage Facilities of Petroleum Product and Hazardous Chemical Compounds (유류 및 유해화학물질 저장시설에서의 토양오염 방지대책)

  • 배우근;홍종철;정진욱;김종호
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.40-47
    • /
    • 2002
  • The practices of the construction and management of the petroleum and hazardous chemical compound storage facilities in Korea were investigated extensively, and the problems were identified. The advanced technologies in the U.S.A were comparatively studied. Considering the effectiveness of leak prevention and applicability, the following measures were suggested. To prevent corrosion of a tank, a clad tank, an interior lining tank, or a double-wall tank were thought to be the most cost effective. For piping. use of non-metalic materials was suggested. A catchment basin seemed to be effective for preventing spills. For monitoring of leaks, constructions of more than one of detection systems, such as an automatic leak detection device. a vapor detection system, a groundwater monitoring system, or a double-wall monitoring system, were recommended.