• Title/Summary/Keyword: stone column

Search Result 97, Processing Time 0.023 seconds

A Comparison of Analysis Methods on Mechanical Behavior of Stone Column Reinforced in the Soft Sabkha Deposit (연약 암염층(Sabkha)에 보강된 스톤컬럼의 침하거동에 관한 해석방법 비교연구)

  • Kim, Se-Won;Lee, Chul-Ho;Kim, Ki-Ho;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.1
    • /
    • pp.53-63
    • /
    • 2011
  • In this study, a composite behavior of stone columns reinforced in a soft ground, Sabkha, has been evaluated by performing a series of field measurements and numerical analyses. Field load tests were performed to verify the effect of the composite ground reinforced by stone columns in Kayan, Saudi. The settlement measured in the field test was compared with the settlement calculated by the Priebe method and the numerical analysis using ABAQUS. It is found that the settlement estimated using the Priebe method significantly overestimated the settlement measured in the field test. In addition, it is confirmed that consideration of confining effect exerted by surrounding adjacent stone columns in a numerical simulation is indispensable to estimate accurately the settlement of stone column composite ground.

Load Carrying Capacity of Geogrid-Encased Stone Columns in Soft Ground (연약지반에 시공되는 지오그리드 감쌈 스톤컬럼의 하중지지 특성)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Journal of the Korean Geosynthetics Society
    • /
    • v.7 no.4
    • /
    • pp.25-36
    • /
    • 2008
  • This paper presents the results of numerical investigation on support mechanism of geogrid-encased stone columns for use in soft ground. A number of cases were analyzed using a axial-and 3D stress-pore pressure coupled model that can effectively model construction sequence and drainage as well as reinforcing effects of geogrid-encased stone columns. The results indicated that the geogrid encasement tends to significantly improve the load carrying of a stone column. Also revealed was that such a confinement effect depends on encasement length and stiffness of geogrid. It is also shown that there exist critical encasement length and stiffness of geogrid for a given condition.

  • PDF

Influence of inclusion of geosynthetic layer on response of combined footings on stone column reinforced earth beds

  • Maheshwari, Priti;Khatri, Shubha
    • Geomechanics and Engineering
    • /
    • v.4 no.4
    • /
    • pp.263-279
    • /
    • 2012
  • The present paper deals with the analysis of combined footings resting on geosynthetic reinforced granular fill overlying stone column improved poor soil. An attempt has been made to study the influence of inclusion of geosynthetic layer on the deflection of the footing. The footing has been idealized as a beam having finite flexural rigidity. Granular fill layer has been represented by Pasternak shear layer and stone columns and poor soil have been represented by nonlinear Winkler springs. Nonlinear behavior of granular fill layer, stone columns and the poor soil has been considered by means of hyperbolic stress strain relationships. Governing differential equations for the soil-foundation system have been derived and solution has been obtained employing finite difference scheme by means of iterative Gauss Elimination method. Results of a detailed parametric study have been presented, for a footing supporting typically five columns, in non-dimensional form in respect of deflection with and without geosynthetic inclusion. Geosynthetic layer has been found to significantly reduce the deflection of the footing which has been quantified by means of parametric study.

Study on settlement characteristics of stone column reinforced in Sabkha through in-site loading test and numerical analysis (현장시험과 수치해석을 통한 암염층(Sabkha)에 보강된 스톤컬럼의 침하거동에 관한 연구)

  • Kim, Se-Won;Yang, Jeong-Hun;Kim, Ki-Ho;Choi, Hang-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1214-1223
    • /
    • 2009
  • In this study, a composite behavior of stone columns reinforced in soft ground, Sabkha, have been evaluated by a series of field measurements and numerical analysis. Field loading tests were performed to verify the effect of the composite ground reinforced by stone columns in Kayan, Saudi. The settlement measured in the field test was compared with the settlement calculated by the Priebe method and the numerical analysis using ABAQUS. It is found that the settlement estimated using the Priebe method significantly overestimated the settlement measured in the field test. In addition, it is confirmed that consideration of confinement effect exerted by surrounding stone columns in a numerical simulation is indispensable to estimate the settlement of composite ground.

  • PDF

A Study on the Ancient Architecture in view of the Stone Remains (focused on the 3 Kingdom Period and Unificated Shilla Period) (석조유구(石造遺構)를 통한 한국(韓國) 고대건축(古代建築)에 관한 연구(硏究) -삼국시대와 통일신라시대를 중심으로-)

  • Cheon, Deuk-Youm;Park, Ji-Min
    • Journal of architectural history
    • /
    • v.8 no.3 s.20
    • /
    • pp.23-38
    • /
    • 1999
  • The purpose of this study is to analogize the appearance of Korean Ancient Architecture in view of the Stone Remains from 3 Kingdom Period to Unificated Shilla Period. But in these period, there is no building remains but some stupas and fine arts. Especially, there are many architectural appearance and revealing signature in these Historical Stone remains. Architectural elements which are analogized by stone remains what has value as historical materials by preservation of original form from 3 Kingdom Preiod to Unificated Shilla Period are as follows : 1) Platform, the representative characteristic of Korean traditional architecture, was frame structure and accumulate structure. And circular or square footing stood a same shape column on it is put on the platform. 2) In the case of column, there used entasis column and inclined column and circular chamfer technique was applied on the top side of it. Upper side of column, capital and head pentrating tie that small bearing block was put on the center of it was joined. And longitu야nal rest(長舌) supported a cross beam. Capital and small bearing block had no bottom heel, and heel side was curved and straight. Centered bracket structure was often used, and multi bracket structure is not used yet. Inward incline technique was used. 3) Inward opening pair door which had lintel, threshold, doorjamb was usually used, Fixing stone was used for structural safety, and circular handle and lock was used for decoration. Handrail was used on the edge of wooden floor for decorative effect and safety. 4) Square rafter and circular rafter were used in the same period and so did flying rafter. Double eaves and single eave were used in the same period but, single eave was usually used. In this period, square rafter was usually used. This would be studied more by comparing with Japanese wooden architecture. 5) Hipped roof was used and half-hipped roof was not used yet. In front of th hip, there are small sculpture called Jap-Sang(雜像), and windbell was hang on the end of the hip rafter. Concave roof tile, convex roof tile, round eaver tile, decorative tile at end of roof ridge were used. Lotus style was well used on the face of roof tile for decoration. From the results of this study, wooden architecture of Unificated Shilla period was simple compare to Koryo dynasty and Chosun dynasty but, it had some brilliant character. It was hard work that analogized the form of non-existent wood architecture of Ancient Korean period by restricted stone remains. But, in addition to the results of this study and research of old documentations, more study should be go on.

  • PDF

Experimental Study on Grouting materials of Grout Column Method for Reinforcement Technology in Groundwater-saturated Mined Cavity (지하수로 포화된 채굴공동 보강을 위한 골재 그라우트 기둥공법의 그라우트 재료에 관한 실험적 연구)

  • Choi, Woo-Seok;Kang, Byung-Chun;Shin, Dong-Choon;Kim, Soo-Lo;Kim, Eun-Sup
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.418-430
    • /
    • 2016
  • In this study, experimental study on cement grout materials containing anti-washout admixtures or accelerators in grout column for reinforcement technology in groundwater-saturated mining cavity was conducted. As a result, the cement milk containing anti-washout admixtures was suitable for mixed aggregates, and the cement mortar containing anti-washout admixtures and the cement milk containing accelerators were suitable for crushed stone aggregate in terms of forming grout column. Especially, in the case of crushed stone aggregate injecting the cement milk containing accelerators, the diameter of the grout column was greatest and the void of the crushed stone aggregate was filled with grout materials. Therefore the case of crushed stone aggregate injecting the cement milk containing accelerators is considered for optimal grout materials and aggregate.

Properties of the Spalling and Fire Resistance on the High Strength RC Column attached with the Stone Panel Using Lightweight Foamed Concrete (경량기포 콘크리트를 이용한 석재패널 부착 고강도 RC 기둥의 내화 및 폭렬특성)

  • Lee, Dong-Gyu;Beak, Dea-Hyun;Kim, Won-Ki;Jo, Yong-Beak;Han, Min-Choel;Han, Choen-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.19-22
    • /
    • 2007
  • This study discussed the prevention of the spalling and improvement of the fire resistance performance how to fill up lightweight foamed concrete on high strength RC column attached with the stone panel. The destructive spalling extremely occur caused by sudden high temperature and increased vapor pressure corresponding to falling the ston panel at all RC column, and the steel bar is exposed. The stone panel fall off about 30 minutes and spalling occur about 70 minutes on Plan RC column, fire endurance paint, and fire endurance mortar, so it can be confirmed that fire endurance paint and mortar, which is used as fire endurance material, are not effective. In the other side, it can be protected from fire about $120{\sim}140$ minutes when the lightweight foamed concrete is used as fire endurance material. For the weight loss after the fire test, plain is 33, fire endurance paint is 37%, and fire endurance mortar s 40.7%. And W/B 60%-3 is 53.4%, 60%-1.5 is 40.1%,65%-3 is 39.4%, and 65%-1.5% is 47.1. Overall, the weight loss of the plain is lower than that of the lightweight foamed concrete.

  • PDF

Slope Stability due to Additional Embankment (제방 추가성토에 따른 사면안정)

  • Lee, Seung-Hyun;Jang, In-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3232-3236
    • /
    • 2012
  • Consolidation and remedies for slope stability were considered for the slope with additional embankment. Transferred stresses due to additional embankment were assessed by the derived formula based on elasticity theory. Available remedies for slope stability with additional embankment including JSP method, stone column method and EPS method were studied. Caution needed for using JSP method is high pressure which can result in heaving of adjacent soils. Shortages of used case and noise of construction of stone column method are also considered for the safe remedy for slope stability.

A Study on Design Method of Geogrid Encased Stone Colum for Settlement Reduction in Railroad (철도노반 침하저감을 위한 토목섬유 감쌈 쇄석말뚝 설계방안 고찰)

  • Lee, Dae-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.3
    • /
    • pp.31-38
    • /
    • 2014
  • The geogrid encased stone column (GESC) system, which increases the confinement effect, has been developed to improve the load carrying capacity of stone columns. The resonable design method for calculating the geogrid ring tension force and ultimate bearing capacity that can be applied to the design of GESC is proposed. In order to calculate design procedure for GESC, two ultimate bearing capacities were compared. One is the ultimate bearing capacity measured using data of the field loading test in light railway site and the other is the ultimate bearing capacity using suggested design procedure of GESC. The results indicated that design method of GESC higher ultimate bearing capacities compared with field loading test.

Numerical Investigation of Load Carrying Capacity of Geogrid-Encased Stone Columns under Foundation Load (구조물 기초하중 작용시 지오그리드 보강 쇄석말뚝의 하중지지 특성에 관한 수치해석 연구)

  • Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.75-86
    • /
    • 2009
  • This paper presents the results of a numerical investigation on load carrying capacity of geogrid-encased stone columns to use as load carrying column(s) supporting a foundation load. A validated 3D stress-pore pressure coupled model that can effectively show rapid drainage capability of stone columns and encasement effect of geogrid was adopted and a parametric study was carried out on a number of influencing factors. It is shown that the geogrid encased stone columns can be effectively used as foundation load supporting columns in soft ground. The results of numerical investigation were presented so that the relationship between the load carrying capacity of geogrid-encased stone columns and the influencing factors can be identified. Practical implications of the findings are also discussed.