• Title/Summary/Keyword: stimulus intensity

Search Result 113, Processing Time 0.044 seconds

Estimation of Visual Stimulus Intensity From Retinal Ganglion Cell Spike Trains Using Optimal Linear Filter (최적선형필터를 이용한 망막신경절세포 Spike Train으로부터의 시각자극 세기 변화 추정)

  • Ryu, Sang-Baek;Kim, Doo-Hee;Ye, Jang-Hee;Kim, Kyung-Hwan;Goo, Yong-Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.212-217
    • /
    • 2007
  • As a preliminary study for the development of electrical stimulation strategy of artificial retina, we set up a method fur the reconstruction of input intensity variation from retinal ganglion cell(RGC) responses. In order to estimate light intensity variation, we used an optimal linear filter trained from given stimulus intensity variation and multiple single unit spike trains from RGCs. By applying ON/OFF stimulation(ON duration: 2 sec, OFF duration: 5 sec) repetitively, we identified three functional types of ganglion cells according to when they respond to the ON/OFF stimulus actively: ON cell, OFF cell, and ON-OFF cell. Experiments were also performed using a Gaussian random stimulus and a binary random stimulus. The input intensity was updated once every 90 msec(i. e. 11 Hz) to present the stimulus. The result of reconstructing 11 Hz Gaussian and binary random stimulus was not satisfactory and showed low correlation between the original and reconstructed stimulus. In the case of ON/OFF stimulus in which temporal variation is slow, successful reconstruction was achieved and the correlation coefficient was as high as 0.8.

Evaluation of the Device Failure Using Stimulus Artifact in the Cochlear Implantee (인공와우 이식자에서 자극 잡파를 이용한 고장 평가)

  • Heo, Seung-Deok;Kim, Sang-Ryeol;Ahn, Joong-Ki;Jung, Dong-Keun;Kang, Myung-Koo
    • Speech Sciences
    • /
    • v.14 no.2
    • /
    • pp.35-42
    • /
    • 2007
  • The aim of this study is to analyze the correlation between current intensity and amplitude of stimulus artifact on the cochlear implantee, and to find out basic information to check the device failure. Subjects were a prelingual child and 3 postlingual adults with more than severe hearing losses. The charge-balanced biphasic pulses were presented at stimulus rates of 11 pulses per second, each pulse width of $25{\mu}s$ with monopolar mode(MP1+2). Current intensities were delivered at 27.5, 33.7, 41.3, 50.5, 61.9, $75.8{\mu}A$. Stimulus artifacts were recorded by evoked potential system. This procedure was performed just before the initial stimulation, and then, the amplitude of stimulus artifacts were compared with each current intensity. The amplitude of stimulus artifacts was increased significantly according to the current intensity (p<0.01). The results suggest that the change of the amplitude of stimulus artifact can be used as a good cue to check the device failure in the cochlear implantee.

  • PDF

Auditory Evoked Skin Potential in Normal Subjects (정상 성인에서 청성유발 피부전위)

  • Heo, Seung-Deok;Jung, Dong-Keun;Suh, Duk-Joon;Kim, Gwang-Nyeon;Kim, Gi-Ryon;Kang, Myung-Koo;Kim, Lee-Suk
    • Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.81-88
    • /
    • 2005
  • Electrodermal activity(EDA) is a bio-electric signal which occurs at the skin surface during the sweating. EDA reflects the activity of the sympathetic axis of the autonomic nervous system. EDA is associated with the eccrine sweat gland at the palmar and plamar surface. This study was aimed to characterize the relationship between EDA and auditory stimulus intensities. Acoustic stimulus used in this study were 500 Hz, 1 kHz, 2 kHz of narrow band noise, which were representative of speech frequencies in audible range. Stimulus intensity between 90 and 30 dB in 10 dB within dynamic range. After deriving the minimum stimulus intensity(threshold of skin potential) which elicited skin potential, and then the latency and amplitude were derived from waveform of skin potential, each latency and amplitude were compared to stimulus intensity. The waveform of skin potential were recorded stably, and the threshold of skin potential appeared nearly the hearing threshold level of the participant. The latency was decreased and the amplitude was increased according to the increase of the stimulus intensity. These results suggest that auditory evoked skin potential can be applicable to auditory assessment and audiological diagnosis tool.

  • PDF

Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation (고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화)

  • Choi, Yoo-Rim;Lee, Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.

WLSD: A Perceptual Stimulus Model Based Shape Descriptor

  • Li, Jiatong;Zhao, Baojun;Tang, Linbo;Deng, Chenwei;Han, Lu;Wu, Jinghui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.12
    • /
    • pp.4513-4532
    • /
    • 2014
  • Motivated by the Weber's Law, this paper proposes an efficient and robust shape descriptor based on the perceptual stimulus model, called Weber's Law Shape Descriptor (WLSD). It is based on the theory that human perception of a pattern depends not only on the change of stimulus intensity, but also on the original stimulus intensity. Invariant to scale and rotation is the intrinsic properties of WLSD. As a global shape descriptor, WLSD has far lower computation complexity while is as discriminative as state-of-art shape descriptors. Experimental results demonstrate the strong capability of the proposed method in handling shape retrieval.

Physiological and Behavioral Studies on the Stimulating Effect of Strobe Light -III - Heart Rate Change of Jack Mackerel by Strobe Light Intensity - (스트로보광의 자극효과에 관한 행동 생리학적 연구 -III - 스트로보광 강도에 의한 전갱이의 심박수변화 -)

  • 안영일;유원귀문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.2
    • /
    • pp.128-133
    • /
    • 2003
  • Stimulus effects of strobe light on jack mackerel Trachurus japonicus were studied by measuring the heart rate change according to the different strobe light intensity of 5~75 lx$\cdot$s. Heart rate was observed for 60 min: 10 min before, 30 min during and 20 min after the strobe light stimulus. The measurement of heart rate was repeated three times at 2 hour intervals. The results showed that the heart rate increased during stimulus but temporarily decreased immediately after ending of stimulus. The heart rate changes in both during and after stimulus were decreased with reducing light intensities. The heart rate change according to the repeated experiment was not remarkably different under the lower light intensity

Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu)

  • Kim, Young Jin;Yoo, Jun Sang;Hwang, Do Guwn;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • The purpose of this study was to investigate the effect of pulsed magnetic field (PMF) and low frequency low level laser (LFLLL) stimuli on acupoint LI4 (Hegu) using photoplethysmography (PPG). Our PMF system was designed to generate maximum intensity of 0.20 T at a transition time of 0.16 ms, with pulse intervals of 1 Hz. The diode laser with wavelength of 650 nm and power of 5 mW was also employed. It was observed the change of the pulsating blood volume through measuring PPG signals from both hands. These results imply that stimulating acupoint LI4 with PMF and LFLLL improves the circulation of peripheral vascular system. In particular, PMF stimulation brings a big improvement of the blood flow even with short term stimulation of 3-4 minutes compared to LFLLL stimulus.

Effects of Electro-acupuncture's Stimulated Frequency, Intensity, Duration at ST36 on the Small Intestine Motility in Rats (족삼리(足三里) 전침(電鍼)의 주파수(周波數), 강도(强度) 및 자극(刺戟) 시간(時間)이 소장(小腸) 수송능(輸送能)에 미치는 영향(影響))

  • Kim, Yong-Jeong;Park, Sang-Moo;Cha, Suk;Yun, Jeong-Ahn;Yu, Yun-Jo;Kang, Byung-Ki;Kim, Kang-San
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.175-185
    • /
    • 2006
  • Objectives : This study was designed to investigate effects of electro-acupuncture's stimulated frequency, intensity, duration at 5736 on tile Small Intestine Motility in Rats. Methods The motor activity of small intestine in rats was evaluated by intestinal transportation rate. Changes in tile motility of ileum in vivo was measured at 10 minutes after electro-acupuncture. Various kinds of stimulus-frequency were used in this experiment: 2 Hz, 50 Hz, 100 Hz, 2 Hz-4 trains, 8 Hz groups treated with EA of the condition in S mA, 1 ms pulse duration, 30 minutes stimulated duration. Three different stimulus-intensity were used: 1, 5, 10 mA groups treated with EA of the condition in 2 Hz, 1 ms pulse duration, 30 minutes stimulated duration. Six different stimulus-duration were used: 10, 20, 30, 40, 50, 60 minutes groups treated with EA of the condition in 2 Hz, 5 mA, 1 ms pulse duration. Results : 2 and 100 Hz groups significantly increased the small intestine motility, but 50 Hz group did not induce a significant change. Besides, small intestine motility was significantly increased only in 5 mA intensity (5 times twitch). futhermore, at least 20 minutes EA treatment was necessary to increase the small intestine motility. Conclusion : Those basic data form this study can be applied to established the effective treatment of EA for gastrointestinal diseases in the clinical field.

  • PDF

Changes in Nerve Excitability Depending on Intensity of Neural Stretching (신경 신장 적용 강도에 따른 신경흥분성 변화)

  • Kim, Jong-Soon
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.195-203
    • /
    • 2021
  • Purpose: Neurodynamic tests are used to examine neural tissue in patients with neuro-musculoskeletal disorders, although this has not yet been established in the intensity of nerve tension application. This study aimed to investigate the acute effects of neural stretching intensity on nerve excitability using the latency and amplitude of nerve conduction velocity test (NCV) analysis. Methods: Thirty young, healthy male and female subjects (mean age = 21.30 years) voluntarily participated in this study. Nerve excitability was assessed using the median sensory NCV test. The latency and amplitude of the NCV test were measured under four different conditions: reference phase (supra-maximal stimulus, without neural stretching), baseline phase (2/3 of the supra-maximal stimulus, without neural stretching), weak stretch phase (2/3 of the supra-maximal stimulus, with weak neural stretching), and strong stretch phase (2/3 of the supra-maximal stimulus, with strong neural stretching). Results: The NCV latency was significantly delayed after one minute of neural stretching at the baseline, weak phase, and strong phase in comparison with the reference phase. The NCV latency was significantly delayed by increasing the strength of neural stretching. Furthermore, the NCV amplitude was significantly increased at the weak and strong phases, which were under neural stretching, in comparison with the baseline phase. The NCV amplitude was significantly increased by increasing the strength of the neural stretching. Conclusion: Transient neural stretching as a neurodynamic test can increase the sensitivity of the nerve without negatively affecting the nervous system. However, based on the results of this study, strong neural stretching in the neurodynamic test may delay the transmission of nerve impulses and hypersensitivity.