• Title/Summary/Keyword: stimulator

Search Result 332, Processing Time 0.025 seconds

Development of Electrical Stimulator for Auditory Stimulation (청각 자극용 전기자극기 개발)

  • Heo, Seung-Deok;Jung, Dong-Keun;Kim, Lee-Suk;Kim, Gwang-Nyeon;Kang, Myung-Koo;Kim, Jae-Ryong;Kim, Gi-Ryon
    • Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.201-211
    • /
    • 2004
  • This paper introduces a development of an electrical stimulator for auditory stimulation. The electrical stimulator is useful in neurotological diagnosis, audiological evaluation, candidate selection for cochlear implantation, optimal device selection and decision making of MAP strategy for severe-to-profound hearing impaired persons. The development was based on sound parameters of auditory brainstem responses and auditory electrophysiological characteristic such as effective firing of auditory nerve and recording evoked potentials during refractory period of neuron. Besides pulse parameter could adjustable by programming for more varied electrical stimulation evoked response audiometry. Using the electrical stimulator, electrical square pulse was applied to promontory, and electrically evoked auditory brainstem response and electrically middle latency response were successfully recorded in cats.

  • PDF

Experience of Right Leg Pain Control by Left Epidural Space Inserted Spinal Cord Stimulator -A case report- (우하지통 환자에서 좌측 경막외강에 삽입된 척수자극기의 치료 경험 -증례 보고-)

  • Kim, Bum Jin;Lee, Woo Yong;Woo, Seung Hoon;Hong, Ki Hyeok
    • The Korean Journal of Pain
    • /
    • v.18 no.2
    • /
    • pp.214-217
    • /
    • 2005
  • Spinal cord stimulation (SCS) was first attempted by Shearly et al for the relief of intractable pain. A spinal cord stimulator has traditionally been used for failed back surgery syndrome (FBSS) angina pectoris, complex regional pain syndrome (CRPS) and ischemic pain in the extremity. However, the complications associated with the use of a spinal cord stimulator, such as wound infection, hematoma, lead migration and device malfunction; make its long term application difficult. Here, our experience of an interesting case, in which intractable right leg pain was controlled using a spinal cord stimulator placed in the left epidural space, is reported, with a review of the literature.

ELECTRICAL STIMULATION FOR THE RESTORATION OF GAIT FUNCTION IN HEMIPLEGIC PATIENTS (일측 마비환자의 전기자극에 의한 보행기능의 회복)

  • Jeong, D.H.;Park, B.R.;Kim, S.S.;Lee, C.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.203-208
    • /
    • 1992
  • In order to restore the gait function by functional electrical stimulation(FES) in hemiplegic patients, an electrical stimulator and foot sensor were developed on the basis of optimal parameters which resulted from animal experiments. Physical properties of the soleus muscle were quite different from those of themedial gastrocnemius muscle, that is, the former had a characteristic or slow muscle and the letter had a characteristic of fast muscle in rats. Optimal parameters for electrical stimulation were 0.2ms of pulse width and 20Hz of frequency in the soleus muscle and 0.3ms, 40Hz in the medial gastrocnemius muscle. Amplitude modulated electrical stimulator with -15V of maximal output was made and automatic on-off time if the stimulator was 5 seconds. The foot sensor composed of 3 sensors in 3 pressure points of the foot was made in order to control the gai t function by closed loop feedback system. The gait function was improved by using the stimulator and foot sensor in peroneal palsy. These results suggest that the electrical stimulator with closed loop feedback system may restore the gait function in hemiplegic patients.

  • PDF

Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation (저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현)

  • Yoon, Wan-Oh;Kang, Suk-Youb;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.

Design of PLC-based Natural Gas Liquefaction Process Plant Stimulator (PLC 기반 천연 가스 액화 공정 플랜트 Stimulator 설계)

  • Kim, Hyoung Jean
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.459-460
    • /
    • 2010
  • 본 연구에서는 PLC 기반의 LNG 플랜트 Stimulator 를 설계하였다. 시뮬레이터와 제어 시스템간의 연계를 구현하기 위한 기본 플랫폼과 구성 요소를 설계하였고 개발 방법론도 정립하였다. 이 설계안을 기반으로 향후 시스템 구축이 완료되면 제어 로직 검증에 활용할 계획이며 이는 LNG 플랜트의 경제성과 안전성 확보에 일조를 할 것으로 기대한다.

Safety Requirements and Test Methods of a Radiofrequency Stimulator

  • Park, Sang-Geon
    • Journal of information and communication convergence engineering
    • /
    • v.14 no.3
    • /
    • pp.191-199
    • /
    • 2016
  • In this study, we investigate the safety requirements and test methods of a radiofrequency stimulator. The main test items include controls of a minimum output, accommodation range, and output parameters that have been known as the safety requirements in conformity with international standards. As the test criteria for controlling the minimum output, an increase or decrease in a unit of 1 mA or 1 V or less was applied to the output amplitude regulator for both continuous and discontinuous control, and the output at the minimum setting was manipulated to not exceed 2% of the maximum setting. For controlling the output parameters, one of the representative test criteria states that the current limit of 250 mA should be equal to or less than 1,500 Hz. Consequently, when applying the radiofrequency stimulator on the human body, we need to ensure that the safety requirements conform to the international standards.

Treatment of Failed Back Surgery Syndrome with a Spinal Cord Stimulator -A report of 2 cases- (척추수술후증후군에서 척수자극술을 이용한 치료경험 -증례 보고-)

  • Park, Chan Hong;Cho, Chul Bum
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.123-126
    • /
    • 2006
  • Spinal cord stimulation (SCS) has been used since 1967 for refractory chronic pain. SCS has recently undergone a variety of technical modifications and advances, and it has been applied in a variety of pain conditions. SCS has been most commonly applied for those patients with chronic back and leg pain and failed back surgery syndrome (FBSS). The clinical hallmark of FBSS is chronic postoperative pain. The pain pattern varies and the pain may show an axial or radicular distribution. Chronic intractable pain after FBSS is difficult to treat. This report describes our experience with treating chronic pain in two patients who suffered from FBSS with a spinal cord stimulator. A permanent spinal cord stimulator was implanted after a successful trial of stimulation with temporarily implanted electrodes. After 5 months of follow-up, the two patients had satisfactory improvement of their pain.

바이오센서

  • 홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.109-111
    • /
    • 1989
  • An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients.

  • PDF

Stimulus artifact suppression on the type of Nerve Stimulator. (신경지극기 형태에 따른 자극 Artifact 제거 방법에 대한 연구)

  • Yoo, S.K.;Min, B.G.;Kim, J.W.;Kim, J.W.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.209-212
    • /
    • 1992
  • A major technical problem in encountered in nerve stimulation technique is the control of stimulus artifact and the convenience of nerve stimulator. The artifacts remained must be removed by processing the contaminated signal. This paper discusses about the artifact cancellation algorithms in constant voltage type nerve stimulator(CVS) and constant current type nerve stimulator(CCS).

  • PDF

fMRI STUDTY ON HUMAN BRAIN'S ACTIVATION BY THE BRAIN STIMULATOR

  • Jeong, Hee-Chang;Choe, Bo-Young;Chung, Sung-Taek;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.359-359
    • /
    • 2002
  • Brain Stimulator processes both visual and audible stimulus and send them human sensory organ. The stimulus was accepted by our sensory organ effect upon human mental function. In this study, we examine the actual effect of commercial brain stimulator using tMRI system.

  • PDF