• Title/Summary/Keyword: still images

Search Result 750, Processing Time 0.024 seconds

A Comparative Study on Awareness of Middle School Students, School Parents, and Human Resources Directors in Industrial Institutions about Admission into Specialized High Schools and Career after Graduating from Specialized High Schools (특성화고 진학 및 졸업 후 진로에 대한 중학생, 학부모, 산업체 인사 담당자의 인식 비교 연구)

  • Lee, Byung-Wook;Ahn, Jae-Yeong;Lee, Chan-Joo;Lee, Sang-Hyun
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.48-67
    • /
    • 2013
  • This study tried to suggest implications about operation direction of specialized high schools (SHS) by researching awareness of middle school students (MSS), school parents (SP), human resources directors in industrial institutions (HRDII) who will be the main users of SHS education, about entering SHS and career after graduating from SHS. Seniors of middle school, SP and HRDII in Asan, Chungnam were the subject of this survey research. The summary of the result of this study is as follow: First, MSS and SP usually hoped to enter general high schools rather than vocational education schools such as SHS, meister high schools, and MSS considered school records and SP considered aptitude and talent for the factors to choose high school. Second, MSS, SP, and HRDII recognized purposes of SHS as improvement of talent and aptitude, and getting a job. As for positive images of SHS, they recognized it as applying talent and aptitude to life early, getting good jobs easily, fast independence after graduation, and learning excellent technologies, and as for negative images of SHS, they recognized it as social prejudices and discrimination, students with bad school records enter them, disadvantages about promotion and wages, and being unfavorable for entering universities. They also recognized education of SHS as being effective for improvement of basic and executive ability and key competency, development of creative human resources, and improvement of right personality and courteous manners. Third, many MSS and SP showed intention to enter SHS if it is established in Asan. They wished to enter SHS because they would like to apply their aptitude and talent to life early, learn excellent skill, and hope for early employment, on the other hand, they did not wish to enter SHS because it was not suited for their aptitude and talent, awareness about SHS is low, it is unfavorable to enter universities, and there were social prejudices and discrimination. They also similarly hoped for getting jobs and entering universities after graduating from SHS. And the reason they wanted to get a job was usually because they want to be successful by advancing into society early, or because it is still hard to get a job even after graduate from the university, on the other hand, the reason they want to enter university is because is usually in-depth education about major and social discrimination about level of education. The ability to perform duties forms the greatest part of the employment standard that MSS, SP, and HRDII aware. MSS and SP usually hoped for industrial, home economics and housework and commercial majors in SHS, and considered aptitude and talent, the promising future, and being favorable for employment for choosing major. The reason HRDII hire SHS student was to develop student into talent of industrial institution, ability of student, and need for manpower with high school graduation level, and there were also partial answer that they can hire SHS student if they have ability to perform duties. The proposals about operation direction of SHS according to the results above are as follow: SHS should diversify major and curriculum to meet various requirements of student and parents, establish SHS admission system based on career guidance, and improve student's ability to perform duties by establishing work-based learning. The Government should organize work-to-school policy to enable practical career development of students from SHS, and promote relevant policy to reinforcing SHS education rather than quantitative evaluation such as employment rate, and cooperative support from each government departments is required to make manpower with skill related to SHS to get proper evaluation and treatment.

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Study of optimum growth condition of phase change Ge-Sb-Te thin films as an optical recording medium using in situ ellipsometry (In situ 타원법을 사용한 광기록매체용 Ge-Sb-Te 박막의 최적성장조건 연구)

  • Kim, Sang-Youl;Li, Xue-Zhe
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.23-32
    • /
    • 2003
  • The spectroe-ellipsometric constant $\Delta$, Ψ and the ellipsometric growth curves at the wavelength of 632.8 nm are collected. These are critically examined to find out the optimum growth condition of phase change $Ge_2Sb_2Te_5(GST)$ thin films as an optical recording medium. GST films are prepared using DC magnetron sputtering technique, under the selected experimental conditions of Ar gas pressure (5 mTorr, 7 mTorr and 10 mTorr), DC power of sputtering gun (15 W, 30 W and 45 W), and substrate temperature (from room temperature to 18$0^{\circ}C$). Based on the three film model, the density distribution of deposited GST films are obtained versus Ar gas pressure and DC power by analyzing spectro-ellipsometric data. The calculated evolution curves at the wavelength of 632.8 nm, are fit into the in situ observed ones to get information about the evolution of density distribution during film growth. The density distribution showed different evolution curves depending on deposition conditions. The GST films fabricated at DC power of 30 W or 45 W, and at Ar gas pressure of 7 mTorr turned out to be the most homogeneous one out of those prepared at room temperature, even though the maximum density difference between the dense region and the dilute region of the GST film was still significant (~50%). Finally, in order to find the optimum growth condition of homogeneous GST thin films, the substrate temperature is varied while Ar gas pressure is fixed at 7 mTorr and DC power at 30 W and 45 W respectively. A monotonic decrease of void fraction except for a slight increase at 18$0^{\circ}C$ is observed as the substrate temperature increases. Decrease of void fraction indicates an increase of film density and hence an improvement of film homogeneity. The optimum condition of the most homogeneous GST film growth turned out to be 7 mTorr of Ar gas pressure, 15$0^{\circ}C$ of substrate temperature. and 45 W of DC power. The microscopic images obtained using scanning electron microscope, of the samples prepared at the optimum growth condition, confirmed this conclusion. It is believed that the fabrication of homogeneous GST films will be quite beneficial to provide a reliable optical recording medium compatible with repeated write/erase cycles.

Comparison of Forest Carbon Stocks Estimation Methods Using Forest Type Map and Landsat TM Satellite Imagery (임상도와 Landsat TM 위성영상을 이용한 산림탄소저장량 추정 방법 비교 연구)

  • Kim, Kyoung-Min;Lee, Jung-Bin;Jung, Jaehoon
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.449-459
    • /
    • 2015
  • The conventional National Forest Inventory(NFI)-based forest carbon stock estimation method is suitable for national-scale estimation, but is not for regional-scale estimation due to the lack of NFI plots. In this study, for the purpose of regional-scale carbon stock estimation, we created grid-based forest carbon stock maps using spatial ancillary data and two types of up-scaling methods. Chungnam province was chosen to represent the study area and for which the $5^{th}$ NFI (2006~2009) data was collected. The first method (method 1) selects forest type map as ancillary data and uses regression model for forest carbon stock estimation, whereas the second method (method 2) uses satellite imagery and k-Nearest Neighbor(k-NN) algorithm. Additionally, in order to consider uncertainty effects, the final AGB carbon stock maps were generated by performing 200 iterative processes with Monte Carlo simulation. As a result, compared to the NFI-based estimation(21,136,911 tonC), the total carbon stock was over-estimated by method 1(22,948,151 tonC), but was under-estimated by method 2(19,750,315 tonC). In the paired T-test with 186 independent data, the average carbon stock estimation by the NFI-based method was statistically different from method2(p<0.01), but was not different from method1(p>0.01). In particular, by means of Monte Carlo simulation, it was found that the smoothing effect of k-NN algorithm and mis-registration error between NFI plots and satellite image can lead to large uncertainty in carbon stock estimation. Although method 1 was found suitable for carbon stock estimation of forest stands that feature heterogeneous trees in Korea, satellite-based method is still in demand to provide periodic estimates of un-investigated, large forest area. In these respects, future work will focus on spatial and temporal extent of study area and robust carbon stock estimation with various satellite images and estimation methods.

[ $^{99m}Tc-DISIDA$ ] Scintigraphic Diagnosis Of Extrahepatic Hepatocellular Carcinoma Metastasis : Comparison with Primary Hepatocellular Carcinoma ($^{99m}Tc-DISIDA$ 신티그래피를 이용한 간세포암 간외 전이의 진단 : 원발 간세포암과의 비교)

  • Chung, Soo-Kyo;Kim, Sung-Hoon;Baik, Joon-Hyun;Kim, Young-Joo;Chun, Kyung-Ah;Park, Seog-Hee;Bahk, Yong-Whee;Shin, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.484-491
    • /
    • 1995
  • It is well known that hepatobiliary agent are taken up by metastatic hepatocellular carcinoma(HCC) as well as primary HCC. But the reported cases of the extrahepatic metastasis of HCC diagnosed by hepatobiliary scintigraphy are for the most part hematogenous ones. The relation of the uptake pattern of hepatobiliary agent in the primary and metastatic HCC is also still remains unknown. So we undertook this study to evaluate the relation of the hepatobiliary scintigraphic patterns of primary and metastatic HCC with different metastatic routes. Nine patients with primary HCC and twelve cases of metastatic HCC including four lung metastases, one bone metastasis, one right atrial metastasis, one peritoneal wall metastasis, and five lymph node metastases were studied with $^{99m}Tc-DISIDA$ scintigraphy. The images were taken on 10, 30 minutes, 1, 2, 4-6 hours. The overall detection rates of hematogenous metastases(lung and bone) is 60%(3 of 5), direct metastasis(right atrium and peritoneal wall), 100%(2 of 2) and lymphatic metastases, 0%(0 of 5). In four of five metastatic cases demonstrated with hepatobiliary scintigraphy, biliary agent is also taken up by primary HCC lesions. And the appearing time of the radioactivity in the direct metastatic HCC lesioin is same as that of primary HCC and in the cases of hematogenous metastasis, earlier than that of primary HCC. Hepatobiliary scintigraphy is more useful in the diagnosis of the metastatic HCC than primary HCC, in the cases of hematogenous and direct metastasis.

  • PDF

Urban archaeological investigations using surface 3D Ground Penetrating Radar and Electrical Resistivity Tomography methods (3차원 지표레이다와 전기비저항 탐사를 이용한 도심지 유적 조사)

  • Papadopoulos, Nikos;Sarris, Apostolos;Yi, Myeong-Jong;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.56-68
    • /
    • 2009
  • Ongoing and extensive urbanisation, which is frequently accompanied with careless construction works, may threaten important archaeological structures that are still buried in the urban areas. Ground Penetrating Radar (GPR) and Electrical Resistivity Tomography (ERT) methods are most promising alternatives for resolving buried archaeological structures in urban territories. In this work, three case studies are presented, each of which involves an integrated geophysical survey employing the surface three-dimensional (3D) ERT and GPR techniques, in order to archaeologically characterise the investigated areas. The test field sites are located at the historical centres of two of the most populated cities of the island of Crete, in Greece. The ERT and GPR data were collected along a dense network of parallel profiles. The subsurface resistivity structure was reconstructed by processing the apparent resistivity data with a 3D inversion algorithm. The GPR sections were processed with a systematic way, applying specific filters to the data in order to enhance their information content. Finally, horizontal depth slices representing the 3D variation of the physical properties were created. The GPR and ERT images significantly contributed in reconstructing the complex subsurface properties in these urban areas. Strong GPR reflections and highresistivity anomalies were correlated with possible archaeological structures. Subsequent excavations in specific places at both sites verified the geophysical results. The specific case studies demonstrated the applicability of ERT and GPR techniques during the design and construction stages of urban infrastructure works, indicating areas of archaeological significance and guiding archaeological excavations before construction work.

Analyzing animation techniques used in webtoons and their potential issues (웹툰 연출의 애니메이션 기법활용과 문제점 분석)

  • Kim, Yu-mi
    • Cartoon and Animation Studies
    • /
    • s.46
    • /
    • pp.85-106
    • /
    • 2017
  • With the media's shift into the digital era in the 2000s, comic book publishers attempted a transition into the new medium by establishing a distribution structure using internet networks. But that effort shied from escaping the parallel-page reading structure of traditional comics. On the other hand, webtoons are showing divers changes by redesigning the structure of traditional sequential art media; they tend to separate and allot spaces according to the vertical scroll reading method of the internet browser and include animations, sound effects and background music. This trend is also in accordance with the preferences of modern readers. Modern society has complicated social structures with the development of various media; the public is therefore exposed to different stimuli and shows characteristics of differentiated perceptions. In other words, webtoons display more relevant and entertaining characteristics by inserting sounds and using moving texts and characters in specific frames, while traditional comics require an appreciation of withdrawal and immersion like other published media. Motions in webtoons are partially applied for dramatic tension or to create an effective expression of action. For example, hand-drawn animation is adopted to express motions by dividing motion images into many layers. Sounds are also utilized, such as background music with episode-related lyrics, melodies, ambient sounds and motion-related sound effects. In addition, webtoons provide readers with new amusement by giving tactile stimuli via the vibration of a smart phone. As stated above, the vertical direction, time-based nature of animation motions and tactile stimuli used in webtoons are differentiated from published comics. However, webtoons' utilization of innovative techniques hasn't yet reached its full potential. In addition to the fact that the software used for webtoon effects is operationally complex, this is a transitional phenomenon since there is still a lack of technical understanding of animation and sound application amongst the general public. For example, a sound might be programmed to play when a specific frame scrolls into view on the monitor, but the frame may be scrolled faster or slower than the author intended; in this case, sound can end before or after a reader sees the whole image. The motion of each frame is also programmed to start in a similar fashion. Therefore, a reader's scroll speed is related to the motion's speed. For this reason, motions might miss the intended timing and be unnatural because they are played out of context. Also, finished sound effects can disturb the concentration of readers. These problems come from a shortage of continuity; to solve these, naturally activated consecutive sounds or animations, like the simple rotation of joints when a character moves, is required.

Application of Borehole Radar to Tunnel Detection (시추공 레이다 탐사에 의한 지하 터널 탐지 적용성 연구)

  • Cho, Seong-Jun;Kim, Jung-Ho;Kim, Chang-Ryol;Son, Jeong-Sul;Sung, Nak-Hun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.4
    • /
    • pp.279-290
    • /
    • 2006
  • The borehole radar methods used to tunnel detection are mainly classified into borehole radar reflection, directional antenna, crosshole scanning, and radar tomography methods. In this study, we have investigated the feasibility and limitation of each method to tunnel detection through case studies. In the borehole radar reflection data, there were much more clear diffraction signals of the upper wings than lower wings of the hyperbolas reflected from the tunnel, and their upper and lower wings were spreaded out to more than 10m higher and lower traces from the peaks of the hyperbolas. As the ratio of borehole diameter to antenna length increases, the ringing gets stronger on the data due to the increase in the impedance mismatching between antennas and water in the boreholes. It is also found that the reflection signals from the tunnel could be enhanced using the optimal offset distance between transmitter and receiver antennas. Nevertheless, the borehole radar reflection data could not provide directional information of the reflectors in the subsurface. Direction finding antenna system had a advantage to take a three dimensional location of a tunnel with only one borehole survey even though the cost is still very high and it required very high expertise. The data from crosshole scanning could be a good indicator for tunnel detection and it could give more reliable result when the borehole radar reflection survey is carried out together. The images of the subsurface also can be reconstructed using travel time tomography which could provide the physical property of the medium and would be effective for imaging the underground structure such as tunnels. Based on the results described above, we suggest a cost-effective field procedure for detection of a tunnel using borehole radar techniques; borehole radar reflection survey using dipole antenna can firstly be applied to pick up anomalous regions within the borehole, and crosshole scanning or reflection survey using directional antenna can then be applied only to the anomalous regions to detect the tunnel.