• Title/Summary/Keyword: stiffness

Search Result 10,358, Processing Time 0.037 seconds

Measurement of Flexural Modulus of Lamination Layers on Flexible Substrates (유연 기판 위 적층 필름의 굽힘 탄성계수 측정)

  • Lee, Tae-Ik;Kim, Cheolgyu;Kim, Min Sung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.63-67
    • /
    • 2016
  • In this paper, we present an indirect method of elastic modulus measurement for various lamination layers formed on polymer-based compliant substrates. Although the elastic modulus of every component is crucial for mechanically reliable microelectronic devices, it is difficult to accurately measure the film properties because the lamination layers are hardly detached from the substrate. In order to resolve the problem, 3-point bending test is conducted with a film-substrate specimen and area transformation rule is applied to the cross-sectional area of the film region. With known substrate modulus, a modulus ratio between the film and the substrate is calculated using bending stiffness of the multilayered specimen obtained from the 3-point bending test. This method is verified using electroplated copper specimens with two types of film-substrate structure; double-sided film and single sided film. Also, common dielectric layers, prepreg (PPG) and dry film solder resist (DF SR), are measured with the double-sided specimen type. The results of copper (110.3 GPa), PPG (22.3 GPa), DF SR (5.0 GPa) were measured with high precision.

Study on a recipe of recycled bumper and pristine materials for application of vehicle parts (재활용 범퍼의 효율적인 적용을 위한 신재의 최적 배합비율에 관한 연구)

  • Son, Younggon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.175-180
    • /
    • 2016
  • Waste bumpers from out-of-service vehicles are recycled in the manufacturing process of plastic parts by incorporating pristine materials after removing the coated paint on a bumper. This study examined the chemical properties and mechanical properties of a mixture of recycled bumper and pristine materials as a function of the mixing ratio. When the pristine materials and the recycled bumper pieces were mixed, the stiffness (tensile strength and the flexural modulus) was provided by their composition averages. On the other hand, the toughness (Izod impact strength and the elongation-at-break) was lower than their composition averages (i.e., negative deviation). FTIR analysis showed that these results were due to the absence of the compatibility between the pristine materials and recycled bumper pieces. When the recycled bumper pieces were loaded at more than 30 wt. %, the toughness decreased drastically. A previous study showed that a paint removal efficiency up to 80 wt.% was easily attainable. The other 20 wt.% of paint on the bumper is very difficult to remove. Therefore, this study examined the mechanical properties of a mixture of recycled bumper pieces containing the unremoved paint and recycled bumper pieces without paint. When the recycled bumper pieces containing the unremoved paint were incorporated in only small quantities, the mechanical properties were decreased to a great extent. These results show that the paint removal efficiency is very important in the recycled bumper industry.

Evaluation on the Horizontal Shear Strength of Precast Concrete Slab with the Inverted-Rib-Plus (리브플러스 PC슬래브의 수평전단강도 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Yun Cheul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.156-165
    • /
    • 2011
  • This study investigates the horizontal shear behavior of an interface between precast concrete (PC) and topping concrete(RC), and evaluates the horizontal based on the investigations by the experimental. Horizontal shear strength in connected surface is determined by the roughness an interface and the shear reinforcement or not. In this study, the main experimental parameters are the shear reinforcement types in the shape of loop-type and lattice-type, rebar spacing. A total of four specimens were shear strength tested and manufactured. As a result, the horizontal shear strength of reinforced connected surface was found to be controlled by deformation in vertical direction. Comparison of reinforcement shape, the mean initial crack load loop type specimens, the average maximum load and the junction of the average in terms of initial stiffness, respectively 33.7%, 45.9% and 55.2% were large enough. Evaluation results for shear strength equation of existing standard domestic, the loop-type reinforced 2.32 to 4.23 times, lattice-type reinforced 1.65 to 3.06 times appears to be higher. Behavior of interface or strength of structural design criteria was fairly safe side. It does not have any problems in the applied field is considered.

Dynamic Analysis and Evaluation of a Microgyroscope using Symmetric 2DOF Planar Resonator (대칭형 2자유도 수평 공진기를 이용한 마이크로 자이로스코프의 동특성 해석 및 평가)

  • Hong, Yoon-Shik;Lee, Jong-Hyun;Kim, Soo-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • Conventional microgyroscopes of vibrating type require resonant frequency tuning of the driving and sensing modes to achieve high sensitivity. These tuning conditions depend on each fabricated microgyroscopes, even though the microgyroscopes are identically designed. A new micromachined resonator, which is applicable to microgyroscopes with self-toning characteristics, is presented. Since the laterally driven two degrees of freedom (2DOF) resonator was designed as a symmetric structure with identical stiffness in two orthogonal axes, the resonator is applicable to vibrating microgyroscopes, which do not need mode tuning. A dynamic model of the resonator was derived considering gyroscopic application. The dynamic model was evaluated by experimental comparison with fabricated resonators. The microgyroscopes were fabricated using a simple 2-mask-process of a single polysilicon layer deposited on an insulator layer. The feasibility of the resonator as a vibrating microgyroscopes with self-tuning capability is discussed. The fabricated resonators of a particular design have process-induced non-uniformities that cause different resonant frequencies. For several resonators, the standard deviations of the driving and sensing frequencies were as high as 1232Hz and 1214Hz, whereas the experimental average detuning frequency was 91.75Hz. The minimum detuned frequency was 68Hz with $0.034mVsec/^{\circ}$ sensitivity. The sensitivity of the microgyroscopes was low due to process-induced non-uniformity; the angular rate bandwidth, however, was wide. This resonator could be successfully applicable to a vibrating microgyroscopes with high sensitivity, if improvements in uniformity of the fabrication process are achieved. Further developments in improved integrated circuits are expected to lower the noise level even more.

  • PDF

The effect of viewing distance and the speed of motion-in-depth on visual fatigue (시각적 피로도에 영향을 미치는 시청거리와 깊이방향의 운동속도)

  • Kham, Kee-Taek;Li, Hyung-Chul;Lee, Seung-Hyun
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.169-180
    • /
    • 2009
  • The present study have investigated the effect of the characteristics of stereoscopic images and viewing environment on visual fatigue. We manipulated the speed of stereo images with motion-in-depth and viewing distance, which were used as representative variables of the characteristics of stereo image and viewing environment, respectively. Visual fatigue was evaluated with use of a subjective questionnaire which is consisting of 5 different and independent factors: "Eye pain", "Visual stress," "Nauseousness", "Body stiffness", and "Blurriness". In general, when viewing time increased from 10 minutes to 20 and 40 minutes, observers felt severe visual fatigue. Among other factors, only the factor score of "Nauseousness" was significantly increased as the speed of object moving in depth became faster. When viewing distance was increased, the score of "Blurriness" was decreased. These results suggest that different kind of the visual fatigue might be induced depending on characteristics of the stereo images and viewing environment.

  • PDF

Short-term Low-dose Oral Corticosteroid Therapy of Impingement Syndrome of the Shoulder: A Comparison of the Clinical Outcomes to Intra-articular Corticosteroid Injection

  • Kim, Young Bok;Kim, Young Chang;Kim, Ji Wan;Lee, Sang Jin;Lee, Sang Won;Choi, Hong Joon;Lee, Dong Hyun;Kim, Joo Young
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.50-56
    • /
    • 2014
  • Background: To assess the clinical outcomes of short-term oral corticosteroid therapy for impingement syndrome of the shoulder and determine whether it can be substituted as an alternative to the intra-articular injection. Methods: The clinical outcomes of the 173 patients, the oral steroid group (n=88) and the injection group (n=85), were measured at 3 weeks, 2, 4, and 6 months postoperatively. The clinical outcomes were assessed by measuring the the University of California at Los Angeles (UCLA) score, visual analog scale (VAS) and range of motion (ROM) at every follow-up. Any complications and recurrence rate were noted. A relationship between the treatment outcomes and factors such as demographic factors, clinical symptoms and radiographic findings were determined. Results: No difference was observed in VAS and UCLA scores between the two groups, but forward flexion and internal rotation of ROM were significantly improved in the injection group at the 2nd and 4th postoperative month (p < 0.05). At 6th postoperative month, recurrence rate of symptoms was 26% in the oral steroid group and 22% in the injection group. No major adverse effects were observed. When the clinical outcomes of the oral steroid group were compared to either demographic, clinical symptoms, or radiographic findings, UCLA score was found to be significantly low (p < 0.05) in patients with joint stiffness and UCLA score, whereas VAS score was significantly improved in patients with night pain (p < 0.05). Conclusions: Short-term low-dose oral corticosteroid therapy of impingement syndrome showed comparable clinical outcomes to intra-articular injection without any remarkable adverse effects. Low-dose oral steroids can be regarded as a partial alternative to intra-articular injection for the initial therapy of impingement syndrome of the shoulder.

A Study on the End-Uses Performance of Fabrics for Korean Folk Clothes (한복지의 소비성능에 관한 연구)

  • Sung Su-Kwang;Kwon Oh-Kyung;Hwang Ji-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.2 s.38
    • /
    • pp.199-209
    • /
    • 1991
  • In this paper, the fabrics for Korean folk clothes(KFC) undergoes repeated laundering under given condition. After this cyclic laundering was applied, the mechanical properties of the specimen were measured using KES-F system in order to evaluated the end-use performance of fabrics for KFC. And also, the crease recovery of fabrics for KFC were measured by shirley crease recovery tester. 78 different kinds of commercial silk fabrics and polyester fabrics for KFC were used for this study. The experimental results were analysed statistically to relate the mechanical properties and the crease recovery of fabrics for KFC. Furthermore, these changes in dimensional stability, mechanical properties and handle of fabrics for KFC were discussed in comparison with those values for silk fabrics and polyester fabrics. The results obtained are as follows. 1. Regardless of materials, remarkable increase are observed in shrinkage of the fabrics for KFC about repeated laundering, but dull increase are observed in shrinkage after 10 cycles of the repeated laundering. On the other hand, slack extend are observed in dimensions after 20 cycles of the repeated laundering. The shrinkage of fabrics for KFC after 10 cycles of the lundering showed that the silk fabrics are $1.74{\pm}0.33\%$ (warp direction) and $1.35{\pm}0.23\%$ (weft direction) and the polyester fabrics are $1.45{\pm}0.22\%$ (warp direction) and $1.25{\pm}0.23\%$ (weft direction). 2. Except for tensile property, these changes in mechanical properties of fabrics for KFC by laundering have $\pm$ 16 range of bending, shearing, compression, surface, thickness & weight as compared with before laundering. Particularly, the LT and RT about $1\~3$ cycles of the repeated laundering showed remarkable decrease. And SMD, WC, T & W of fabrics for KFC by the laundering were more increased than one for original fabrics. But B, 2HB, G, 2HG, 2HGS were decreased more than one for original fabrics. 3. 'Stiffness', 'Anti-drape', 'Crispness' and 'Scroop' hand values decrease and'Fullness & softness', 'Flexibility & softness' hand values increase with repeated laundering. 4. Remarkable decrease are observed in crease recoveries about $1\~5$ cycles of the repeated lundering, but slack decrease are observed in crease recoveries after 5 cycles of repeated laundering. The crease recovery of fabrics for KFC have negative(-) correlation with LT, RT, G, RC and MMD, This fact implies that the smaller these values, the larger the crease recovery. The crease recovery of fabrics for KFC has a high degree of correlation with the mechanical properties such as shearing, compression, surface property. And also, the crease recovery are expected by measuring the mechanical properties such as G, 2HG, 2HGS, RC, WC, LC, MIU, MMD and SMD, according to the obtained regression equation.

  • PDF

Numerical Analysis of the Flow in a Compliant Tube Considering Fluid-wall Interaction (벽-유체의 상호작용을 고려한 유연관 내부 유동의 수치적 연구)

  • 심은보
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.391-401
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and the results are compared to the existing experimental data. Steady two-dimensional flow in a collapsible channel with initial tension is also simulated and the results are compared with numerical solutions from the literature. Computational results show that as cross-sectional area decreases with the reduction in downstream pressure, flow rate increases and reaches the maximum when the speed index (mean velocity divided by wave speed) is near the unity at the point of minimum cross-section area, indicating the flow limitation or choking (flow speed equals wave speed) in one-dimensional studies. for further reductions in downstream pressure, flow rate decreases. The flow limitation or choking consist of the main reasons of waterfall effect which occurs in the airways, capillaries of lung, and other veins. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is 2, the area throat is located near the downstream end. As this ratio is increased to 3, the constriction moves to the upstream end of the tube.

  • PDF

Effects of Rhythm Exercise Training on Body Composition and Arterial Compliance in Elderly Females (리듬운동이 고령여성의 신체조성과 혈관탄성에 미치는 영향)

  • Kim, Daeyeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.243-250
    • /
    • 2016
  • The body composition and arterial compliance with advanced age increase the risks of cardiovascular diseases, but the elderly can perform rhythm exercise easily, which may positively influence their body composition and arterial compliance. Therefore, this study examined the effects of rhythm exercise training on the body composition and arterial compliance in elderly females. The subjects (n=20) were assigned randomly to either an exercise group (n=10, EX) or non-exercise control group (n=10, CON). The rhythm exercise training for 12 weeks consisted of 3 sessions per week with 60 minutes per session. In addition, the intensity was set to 11-14 of the Borg scale (6-20). The body composition and arterial compliance (pulse wave velocity (PWV)) were measured before and after training. The skeletal muscle mass in the EX was increased significantly (p=0.04) and the right (p=0.002) and left side (p=0.02) of the PWV in the EX were decreased significantly, but the skeletal muscle and both sides of the PWV in the CON were not changed. Elderly females could easily perform rhythm exercise training, which resulted in improvements of the skeletal muscle mass and arterial compliance. Therefore, rhythm exercise training may prevent or delay sarcopenia and reduce the risk of cardiovascular diseases.

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.