• Title/Summary/Keyword: step count

Search Result 137, Processing Time 0.029 seconds

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Step Counts and Posture Monitoring System using Insole Type Textile Capacitive Pressure Sensor for Smart Gait Analysis (깔창 형태의 전기용량성 섬유압력센서를 이용한 보행 횟수 검출 및 자세 모니터링 시스템)

  • Min, Se-Dong;Kwon, Chun-Ki
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.8
    • /
    • pp.107-114
    • /
    • 2012
  • We have developed a textile capacitive pressure sensor for smart gait analysis. The proposed system can convert sensor signal into step counts and pressure levels by different posture. To evaluate the performance of insole type textile capacitive sensor, we measured capacitance change by increment of weights from 10 kg to 100 kg with 10 kg increment using M1 class rectangular weights (four 20 kg weights and two 10 kg weights) which have ${\pm}10%$ tolerance. The result showed non-linearity characteristic of a general capacitive pressure sensor. The test was performed according to a test protocol for four different postures (sitting, standing, standing on a left leg and standing on a right leg) and different walking speeds (1 km/h and 4 km/h). Five healthy male subjects were participated in each test. As we expected, the pressure level was changed by pressure distribution according to posture. Also, developed textile pressure sensor showed higher recognition rate (average 98.06 %) than commercial pedometer at all walking speed. Therefore, the proposed step counts and posture monitoring system using conductive textile capacitive pressure sensor proved to be a reliable and useful tool for monitoring gait parameters.

Characterization for Applying to Optimized Model of Flatform System Step Parts Material for Low-High Platform Railroad Vehicle (저상고상 철도차량용 승강시스템 스텝 부품 소재의 최적화 모델 적용을 위한 특성 평가)

  • Kwak, Hee-Man;Choi, Jung-Muk;Kim, Hyun-Dong;Park, Min-Heung;Kim, Chul-Su
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1381-1388
    • /
    • 2011
  • Recently, Because of weight lighting and tighten safety regulations of the railway vehicle railroad weight lighting and safety improvement technology is internationally required. Slide step for moving the passenger to high flatform in the railroad vehicle is recognized of important parts. However, Due to high price and weight, it is limited. In this research, In order to apply for railroad, it was redesigned to optimize part count and reduce the price and weight. By choosing honeycombcore as a part for enduring high weight and weight lighting, We produce honeycombpanel of sandwich structure which a different kind connected by using existing stainless(STS304)steel and thermo plasticity glue. Finally, we can find that honeycombpanel is suitable for weight lighting and high weight. As well as, with test result, we can prove that low-high platform railway system will be optimized, if steps are applied to honeycombpanel.

  • PDF

Real-time Contaminant Particle Monitoring for Chemical Vapor Deposition of Borophosphosilicate and Phosphosilicate Glass Film by using In-situ Particle Monitor and Particle Beam Mass Spectrometer (ISPM 및 PBMS를 이용한 BPSG 및 PSG CVD 공정 중 발생하는 오염입자의 실시간 측정)

  • Na, Jeong Gil;Choi, Jae Boong;Moon, Ji Hoon;Lim, Sung Kyu;Park, Sang Hyun;Yi, Hun Jung;Chae, Seung Ki;Yun, Ju Young;Kang, Sang Woo;Kim, Tae Sung
    • Particle and aerosol research
    • /
    • v.6 no.3
    • /
    • pp.139-145
    • /
    • 2010
  • In this study, we investigated the particle formation during the deposition of borophosphosilicate glass (BPSG) and phosphosilicate glass (PSG) films in thermal chemical vapor deposition reactor using in-situ particle monitor (ISPM) and particle beam mass spectrometer (PBMS) which installed in the reactor exhaust line. The particle current and number count are monitored at set-up, stabilize, deposition, purge and pumping process step in real-time. The particle number distribution at stabilize step was measured using PBMS and compared with SEM image data. The PBMS and SEM analysis data shows the 110 nm and 80 nm of mode diameter for BPSG and PSG process, respectively.

Motion Sensor Data Normalization Algorithm for Pedestrian Pattern Detection (보행 패턴 검출을 위한 동작센서 데이터 정규화 알고리즘)

  • Kim Nam-Jin;Hong Joo-Hyun;Lee Tae-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.94-102
    • /
    • 2005
  • In this paper, three axial accelerometer was used to develop a small sensor module, which was attached to human body to calculate the acceleration in gravity direction by human motion, when it was positioned in any direction. To measure its wearer's walking or running motion using the sensor module, the acquired sensor data was pre-processed to enable its quantitative analysis. The acquired digital data was transformed to orthogonal coordinate value in three dimension and calculated to be single scalar acceleration data in gravity direction and normalized to be physical unit value. The normalized sensor data was used to detect walking pattern and calculate their step counts. Developed algorithm was implemented in the form of PDA application. The accuracy of the developed sensor to detect step count was about 97% in laboratory experiment.

  • PDF

Efficient CAVLC Decoder VLSI Design for HD Images (HD급 영상을 효율적으로 복호하기 위한 CAVLC 복호화기 VLSI 설계)

  • Oh, Myung-Seok;Lee, Won-Jae;Kim, Jae-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.51-59
    • /
    • 2007
  • In this paper, we propose an efficient hardware architecture for H.264/AVC CAVLC (Context-based Adaptive Variable Length Coding) decoding which used for baseline profile and extended profile. Previous CAVLC architectures are consisted of five step block and each block gets effective bits from Controller block and Accumulator. If large number of non-zero coefficients exist, process for getting effective bits has to iterates many times. In order to reduce this unnecessary process, we propose two techniques, which combine five steps into four steps and reduce process to get efficiency bit by skipping addition step. By adopting these two techniques, the required processing time was reduced about 26% compared with previous architectures. It was designed in a hardware description language and total logic gate count was 16.83k using 0.18um standard cell library.

Microbiological Quality Evaluation for Implementation of a HACCP System in Day-Care Center Foodservice Operations I. Focus on Heating Process and After-Heating Process (보육시설급식소의 HACCP시스템 적용을 위한 미생물적 품질평가 I. 가열조리 및 가열조리후 처리 공정을 중심으로)

  • 민지혜;이연경
    • Journal of Nutrition and Health
    • /
    • v.37 no.8
    • /
    • pp.712-721
    • /
    • 2004
  • The objective of this study was to evaluate the microbiological quality of heating and after-heating processed foods for implementation of a HACCP system in day-care center foodservice operations. The evaluating points were microbial assessment and temperature of foods during receiving, cooking, and serving in heating process. In non-heating process, in addition to monitoring microbial assessment of food during preparation, cooking, and serving steps, the microbial populations of employees' hands and utensils and serving temperature were also evaluated. Microbiological quality was assessed using 3M Petrifilm$^{TM}$ to measure total plate count and coliforms for foods and utensils and Staphylococcus aureus for hands in five Gumi day-care centers. Microbiological quality assessment for foods and utensils is summarized as follows. Microbiological quality of the heating processed foods was satisfactory for cooking and serving steps. The internal temperature of food was above 74$^{\circ}C$. However, temperature control before the serving step was not achieved due to inappropriate time management between the cooking and serving steps. In the after-heating process, the total plate counts of boiled mungbean sprouts salad, blanched spinach salad, com vegetable salad were below the standard at the serving step. The majority of samples showed that coliforms exceeded the norm, which is thought to be the result of the cross-contamination from utensils. These results suggest that it is essential to educate employees on the importance of hand washing and of avoiding cross-contamination by using clean, sanitized equipment to serve food in the after-heating process. Establishing Sanitation Standard Operating Procedures (SSOPs) is an essential part of any HACCP system in day-care center foodservice operations.

A Digital Device-Based Method for Quantifying Motor Impairment in Movement Disorders (디지털 디바이스를 이용한 이상운동증에서의 운동손상 정량화 방법)

  • Bae, Suhan;Yun, Daeun;Ha, Jaekyung;Gwon, Daeun;Kim, Young Goo;Ahn, Minkyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.247-255
    • /
    • 2020
  • Accurate diagnosis of movement disorders is important for providing right patient care at right time. In general, assessment of motor impairment relies on clinical ratings conducted by experienced clinicians. However, this may introduce subjective opinions into scoring the severity of motor impairment. Digital devices such as table PC and smart band with accelerometer can be used for more accurate and objective assessment and possibly helpful for clinicians to make right decision of patient's states. In this study, we introduce quantification algorithms of motor impairment which uses the digital data acquired during four clinical motor tests (Line drawing, Spiral drawing, Nose to finger and Hand flip tests). The step by step procedure of quantifying metrics (Tremor Frequency, Tremor Magnitude, Error Distance, Time, Velocity, Count and Period) are provided with flowchart. The effectiveness of the proposed algorithm is presented with the result from simulated data (normal, normal with tremor and slowness, poor with tremor, poor with tremor and slowness).

Influences of Autonomic Function, Salivary Cortisol and Physical Activity on Cognitive Functions in Institutionalized Older Adults with Mild Cognitive Impairment: Based on Neurovisceral Integration Model (요양병원에 입원한 경도 인지장애 노인의 자율신경 기능, 타액 코티졸과 신체활동 정도가 인지기능에 미치는 영향: Neurovisceral Integration Model 기반)

  • Suh, Minhee
    • Journal of Korean Academy of Nursing
    • /
    • v.51 no.3
    • /
    • pp.294-304
    • /
    • 2021
  • Purpose: This study aimed to investigate objectively measured physical activity (PA) in institutionalized older adults with mild cognitive impairment (MCI) and to elucidate the influence of autonomic nervous function, salivary cortisol, and PA on cognitive functions based on neurovisceral integration model. Methods: Overall cognitive function was evaluated using the mini-mental state examination (MMSE) and executive function was evaluated using semantic verbal fluency test and clock drawing test. Actigraph for PA, HRV and sAA for autonomous function, and the geriatric depression scale for depression were used. Saliva specimens were collected in the morning for sAA and cortisol. Results: Ninety-eight older adults from four regional geriatric hospitals participated in the study. They took 4,499 steps per day on average. They spent 753.93 minutes and 23.12 minutes on average in sedentary and moderate-to-vigorous activity, respectively. In the multiple regression analysis, lower salivary cortisol level (β = - .33, p = .041) and greater step counts (β = .37, p = .029) significantly improved MMSE score. Greater step count (β = .27, p = .016) also exerted a significant influence on verbal fluency, and greater sAA (β= .35, p = .026) was significantly associated with a better clock drawing test result. Conclusion: Salivary cortisol, sAA and physical activity were significantly associated with cognitive functions. To prevent older adults from developing dementia, strategies are needed to increase their overall PA amount by decreasing sedentary time and to decrease salivary cortisol for cognitive function, and to maintain their sympathetic nervous activity for executive function.

Evaluation of Biocompatibility of Extracorporeal Circuit - Development of a Quantification Technique using in-vivo Injection of Tc99m Radioactive Platelets - (체외순환도관의 혈액적합성 평가 - 방사선 동위원소(Tc99m) 활성화 혈소판의 생체 내 주입을 이용한 정량분석법의 개발 -)

  • Lee, Sung-Ho;Sun, Kyung;Choi, Jai-Geol;Son, Ho-Sung;Jung, Jae-Seung;Ahn, Sang-Soo;Oh, Hye-Jung;Lee, Whan-Sung;Lee, Hye-Won;Kim, Kwang-Taik;Jeong, Yoon-Seop;Kim, Young-Ha;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Background: Blood-foreign interaction cause activation of coagulation and inflammatory process that may lead to multiorgan dysfunction and determine the surgical outcomes. Of the methods for assessing the biocompatibility, the platelet adhesion study is considered as the most valuable evaluation step in blood-foreign interaction. As the most studies have used in-vitro or ex-vivo conditions, we have developed a technique of quantification for platelet adhesion on the blood contact surface by using in-vivo injection of radioactive platelets. Material and Method: A coupled bypass circuit was designed to connect the proximal and descending thoracic aorta in 6 piglets(20∼25 Kg). One side of the circuit tube was consisted of a heparin coated PVC tube(10mm in ID, n=6, Experimental group), and the other, a non-heparin coated PVC tube(10mm in ID, n=6, Control group). After cannulation, the blood was circulated through the circuit for 2 hours. Platelet concentrate was prepared from homologous pig blood 24 hours before the experiment. The platelet concentrate was incubated with Tc-99m-HMPAO for 30 min and then centrifuged for 10 min. The supernatant was discarded and the radio-labeling efficacy was measured. The radio-labeled platelet concentrate was mixed with the autologous plasma to make the volume 5 ml, and the mixture was injected intravenously into the experimental animal. After 2 hour circulation, 5 pieces of the specimen(10mm in length each) were obtained from each PVC tube. The radioisotopes were counted with a gamma counter(Cobra ll, Packard, USA), and the ratio of radioisotope count was compared between the control and experimental group. Result: The radioisotope count number was 537.3221.1 Ci/min in the control group and 311.1 184.5 Ci/min in the experimental group(p=0.0104). The ratio between the groups was 1 to 0.58 (p=0.004). Conclusion: In vivo quantification using technetium-99m-HMPAO labeled platelets is simple and reproducible in evaluating platelet adhesion on a foreign surface. We suggest this technique to be a useful tool for blood compatibility test.