• Title/Summary/Keyword: stent

Search Result 713, Processing Time 0.028 seconds

Very Late Stent Thrombosis after Sole Stent-Assisted Coiling at the Paraclinoid Giant Aneurysm : Could Prophylactic Antiplatelet Therapy Be Ceased at the Only 1 Year after Procedure?

  • Shin, Jung-Hoon;Park, Seong-Ho;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.344-347
    • /
    • 2014
  • Stent thrombosis is a major limitation of stent-assisted coiling, which is an effective method for treating wide-necked aneurysms. Although early in-stent thrombosis has been reported, very late stent thrombosis (VLST) (>1 year) has not been reported following implantation of a single self-expandable stent designed for coiling. Herein, the authors present a case of VLST that occurred 14 months after single stent implantation in a large paraclinoid aneurysm with an ultra-wide neck involving the parent artery circumferentially. This case indicates the need for establishing guidelines regarding the optimal duration of prophylactic antiplatelet therapy following stent-assisted coiling, which remains undefined in the neuroendovascular field.

In-Stent Stenosis of Stent Assisted Endovascular Treatment on Intracranial Complex Aneurysms

  • Yoon, Kyeong-Wook;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.485-489
    • /
    • 2010
  • Objective : To introduce the frequency and segment analysis of in-stent stenosis for intracranial stent assisted endovascular treatment on complex aneurysms. Methods : A retrospective study was performed in 158 patients who had intracranial complex aneurysms and were treated by endovascular stent application with or without coil embolization. Of these, 102 patients were evaluated with catheter based angiography after 6, 12, and 18 months. Aneurysm location, using stent, time to stenosis, stenosis rate and narrowing segment were analyzed. Results : Among follow-up cerebral angiography done in 102 patients, 8 patients (7.8%) were shown an in-stent stenosis. Two patients have unruptured aneurysm and six patients have ruptured one. Number of Neuroform stents were 7 cases (7.5%) and Enterprise stent in 1 case (11.1%). Six patients demonstrated in-stent stenosis at 6 months after stent application and remaining two patients were shown at 12 months, 18 months, respectively. Conclusion : In-stent stenosis can be confronted after intracranial stent deployment. In our study, no patient showed symptomatic stenosis and there were no patients who required to further treatment except continuing antiplatets medication. In-stent stenosis has been known to be very few when they are placed into the non-pathologic parent artery during the complex aneurysm treatment, but the authors found that it was apt to happen on follow up angiography. Although the related symptom was not seen in our cases, the luminal narrowing at the stented area may result the untoward hemodynamic event in the specific condition.

Complications of Endotracheal Stent in Three Dogs with Tracheal Collapse (기관허탈이 있는 개들에서 기관 내 Stent 장착 후 나타난 합병증 3례)

  • Seo, Kyoung-Won;Lee, Young-Heun;Chang, Jin-Hwa;Hwang, Cheol-Yong;Yoon, Jung-Hee;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.457-461
    • /
    • 2010
  • Three dogs were presented with signs of recurrence of coughing, dyspnea and difficulty of barking after endotracheal stent placement. On the basis of history taking, physical examination, laboratory tests and radiography, complications of endotracheal stent were suspected. Dog 1 had unfitted stent diameter (stent diameter is larger than tracheal diameter) and getting disentangled of proximal tracheal stent wire. Dog 2 was suspected a foreign body reaction. Dog 3 had the migration of stent caudally. Based on these cases, the veterinarian should accurately evaluate the indicated patients before endotracheal stent and has to select the appropriate stent (diameter, length and location) to prevent complications after endotracheal stent and concern the regular follow-ups to assure proper endotracheal stent placement.

The assessment of the performance of drug-eluting stent using computational fluid dynamics

  • Seo, Tae-Won;Barakat, Abdul I.
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.4
    • /
    • pp.281-288
    • /
    • 2009
  • Numerical investigations have been conducted on the assessment of the performance of drug-eluting stent. Computational fluid dynamics is applied to investigate the flow disturbances and drug distributions released from the stent in the immediate vicinity of the given idealized stent in the protrusion into the flow domain. Our simulations have revealed the drug concentration in the flow field due to the presence of a drug-eluting stent within an arterial segment. Wall shear stress increases with Reynolds number for a given stent diameter, while it increases with stent diameter for a given Reynolds number. The drug concentration is dependent on both Reynolds number and stent geometry. In pulsatile flow, the minimum drug concentration in the zone of inter-wire spacing occurs at the maximum acceleration of the inlet flow while the maximum drug concentration gains at the maximum deceleration of the inlet flow. These results provide an understanding of the flow physics in the vicinity of drug-eluting stents and suggest strategies for optimal performance of drug-eluting stent to minimize flow disturbance.

Stent Design Using Computational Fluid Dynamics (전산유체역학을 이용한 스텐트 설계)

  • Kim, Tae-Dong;Barakat, Abdul;Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1042-1048
    • /
    • 2005
  • Numerical investigation has been made on the stent design to minimize the neointimal hyperplasia. Computational fluid dynamics is applied to investigate the flow distributions in the immediate vicinity of the given idealized stent implanted in the blood vessel. Parametric study on the variations of the number of stouts, stent diameters, stent spacings and Reynolds numbers has been conducted using axi-symmetric Navier-Stokes equations. An initial difficulty in the study is to determine the optimal stent design to understand the flow physics of the flow disturbance induced by stent. The size of recirculation zone around stent is depend on the stent diameter, number of stent wire and Reynolds number but is insensitive to the stent wire spacing. It is also found that when the flow is in acceleration, the flow sees a more favorable pressure gradient, and the separation zones are smaller than the steady flow case. When the flow is in deceleration and the flow sees a more adverse pressure gradient so that the separation zones are larger.

Numerical Study of Flow Pattern and Drug Deposition in Drug-Eluting Stent (약물분출 스텐트 주위 유동형태와 약물침전에 대한 수치해석)

  • Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1053-1060
    • /
    • 2011
  • This study is performed to determine the drug concentration profiles of drug-eluting stents (DES) for an ideal circular ring stent and intertwined stent models for various Reynolds numbers (Re = 200, 400, and 800). The Navier.Stokes equations coupled with the advection-diffusion equation are solved numerically in order to determine how the flow patterns and drug deposition are affected in the in-stent and post-stent regions where flow separation and recirculation occur. The presence of DES within the arterial segment affects the local drug distribution in the flow field. As a result, the drug concentration for the intertwined stent is higher over the in-stent region in comparison with the ideal stents. For a given stent geometry, the local drug concentration in the in-stent region decreases with Reynolds number, while for a given Reynolds number, the local drug concentration is relatively insensitive to the stent geometry. The results show that drug concentration along the arterial wall is significantly higher within the in-stent and post-stent regions for the intertwined stent geometry than for the ideal stent geometries.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

Percutaneous Biliary Metallic Stent Insertion in Patients with Malignant Duodenobiliary Obstruction: Outcomes and Factors Influencing Biliary Stent Patency

  • Ji Hye Kwon;Dong Il Gwon;Jong Woo Kim;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon;Kyu-Bo Sung
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.695-706
    • /
    • 2020
  • Objective: To investigate the technical and clinical efficacy of the percutaneous insertion of a biliary metallic stent, and to identify the factors associated with biliary stent dysfunction in patients with malignant duodenobiliary obstruction. Materials and Methods: The medical records of 70 patients (39 men and 31 women; mean age, 63 years; range, 38-90 years) who were treated for malignant duodenobiliary obstruction at our institution between April 2007 and December 2018, were retrospectively reviewed. Variables found significant by univariate log-rank analysis (p < 0.2) were considered as suitable candidates for a multiple Cox's proportional hazard model. Results: The biliary stents were successfully placed in all 70 study patients. Biliary stent insertion with subsequent duodenal stent insertion was performed in 33 patients and duodenal stent insertion with subsequent biliary stent insertion was performed in the other 37 study subjects. The median patient survival and stent patency time were 107 days (95% confidence interval [CI], 78-135 days) and 270 days (95% CI, 95-444 days), respectively. Biliary stent dysfunction was observed in 24 (34.3%) cases. Multiple Cox's proportional hazard analysis revealed that the location of the distal biliary stent was the only independent factor affecting biliary stent patency (hazard ratio, 3.771; 95% CI, 1.157-12.283). The median biliary stent patency was significantly longer in patients in whom the distal end of the biliary stent was beyond the distal end of the duodenal stent (median, 327 days; 95% CI, 249-450 days), rather than within the duodenal stent (median, 170 days; 95% CI, 115-225 days). Conclusion: The percutaneous insertion of the biliary metallic stent appears to be a technically feasible, safe, and effective method of treating malignant duodenobiliary obstruction. In addition, a biliary stent system with a distal end located beyond the distal end of the duodenal stent will contribute towards longer stent patency in these patients.

Evaluation of a Double-Pigtail Ureteral Stent Fixation in Cats with Complete Ureteral Obstruction

  • Shin, Kyoung-in;Jeong, Soon-wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.115-122
    • /
    • 2020
  • The aim of this study was to evaluate double-pigtail ureteral stent fixation in cats. Medical records of 19 cats (23 ureters) with complete ureteral obstruction that double-pigtail ureteral stent placement were carried out were retrospectively reviewed. The cats were randomly classified into two groups; 13 cats (16 ureters) with double-pigtail ureteral stent fixed to urinary bladder (SF group) and 6 cats (7 ureters) with not fixed to urinary bladder (SNF group). The average age and weight of the cats was 7.4 years and 3.73 kg, respectively. Postoperative complications included chronic renal failure (n = 11), lower urinary track diseases (cystitis, hematuria, pollakiuria) (n = 7), stent migration (n = 6), anemia (n = 5), ascites (n = 2), hyperthermia (n = 1), enteritis (n = 1), oliguria (n = 1), hypotension (n = 1), ureteritis (n = 1), and pyelonephritis (n = 1). Stent migration did not occur in the 16 ureters of the cats in SF group but did occur in 4 out of 7 ureters of the cats in SNF group. The prevention of stent migration by stent fixation was significant (P = 0.04). Among the 13 cats in SF group, only 2 cats developed lower urinary track diseases, while 4 of the 6 cats in SNF group showed symptoms of lower urinary track disease. Thus, the cats that underwent double-pigtail ureteral stent fixation to the urinary bladder developed significantly fewer lower urinary diseases (P = 0.046). In conclusion, double-pigtail ureteral stent fixation to the urinary bladder for treatment of complete ureteral obstruction in cats can effectively prevent stent migration, which is common complication of stent placement.

Percutaneous Enteral Stent Placement Using a Transhepatic Access for Palliation of Malignant Bowel Obstruction after Surgery

  • Won Seok Choi;Chang Jin Yoon;Jae Hwan Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.742-750
    • /
    • 2021
  • Objective: To assess the safety and clinical efficacy of percutaneous transhepatic enteral stent placement for recurrent malignant obstruction in patients with surgically altered bowel anatomy. Materials and Methods: Between July 2009 and May 2019, 36 patients (27 men and 9 women; mean age, 62.7 ± 12.0 years) underwent percutaneous transhepatic stent placement for recurrent malignant bowel obstruction after surgery. In all patients, conventional endoscopic peroral stent placement failed due to altered bowel anatomy. The stent was placed with a transhepatic approach for an afferent loop obstruction (n = 27) with a combined transhepatic and peroral approach for simultaneous stent placement in afferent and efferent loop obstruction (n = 9). Technical and clinical success, complications, stent patency, and patient survival were retrospectively evaluated. Results: The stent placement was technically successful in all patients. Clinical success was achieved in 30 patients (83.3%). Three patients required re-intervention (balloon dilatation [n = 1] and additional stent placement [n = 2] for insufficient stent expansion). Major complications included transhepatic access-related perihepatic biloma (n = 2), hepatic artery bleeding (n = 2), bowel perforation (n = 1), and sepsis (n = 1). The 3- and 12-months stent patency and patient survival rates were 91.2%, 66.5% and 78.9%, 47.9%, respectively. Conclusion: Percutaneous enteral stent placement using transhepatic access for recurrent malignant obstruction in patients with surgically altered bowel anatomy is safe and clinically efficacious. Transhepatic access is a good alternative route for afferent loop obstruction and can be combined with a peroral approach for simultaneous afferent and efferent loop obstruction.