• Title/Summary/Keyword: steel-CFRP

Search Result 316, Processing Time 0.021 seconds

Flexural strengthening of continuous unbonded post-tensioned concrete beams with end-anchored CFRP laminates

  • Ghasemi, Saeed;Maghsoudi, Ali A.;Bengar, Habib A.;Ronagh, Hamid R.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1083-1104
    • /
    • 2015
  • This paper provides the results of an experimental investigation into the flexural behavior of continuous two-span unbonded post-tensioned high strength concrete (HSC) beams, strengthened by end-anchored CFRP laminates of different configurations in the hogging region. Implementing two different configurations of end-anchorage systems consisting of steel plates and bolts and carefully monitoring the development of strains throughout the load history using sufficiently large number of strain gauges, the response of beams including the observed crack propagations, beam deflection, modes of failure, capacity enhancement at service and ultimate and the amount of moment redistribution are measured, presented and discussed. The study is appropriate in the sense that it covers the more commonly occurring two span beams instead of the simply supported beams investigated by others. The experiments reconfirmed the finding of others that proper installation of composite strengthening system is most important in the quality of the bond which is essential for the internal transfer of forces. It was also found that for the tested two span continuous beams, the capacity enhancement is more pronounced at the serviceability level than the ultimate. This is an important finding as the design of these beams is mostly governed by the serviceability limit state signifying the appropriateness of the suggested strengthening method. The paper provides quantitative data on the amount of this capacity enhancement.

Reliability study of CFRP externally bonded concrete beams designed by FIB bulletin 14 considering corrosion effects

  • Dehghani, Hamzeh
    • Advances in concrete construction
    • /
    • v.13 no.2
    • /
    • pp.191-198
    • /
    • 2022
  • FIB is introduced as the sole guideline for the design purpose that results in a practical relationship for the torsional capacity of concrete beams strengthened with carbon fiber-reinforced polymer (CFRP). This study applies first-order reliability method to assess the reliability evaluation of the torsional capacity of CFRP-strengthened beams on the basis of FIB guidelines. In terms of steel reinforcement losses, this study applies a corrosion model to investigate the ceaseless deterioration of the existing structure. Hence, the average of reliability indices varies between 2.68 and 2.80, indicating the reliability viewpoint of the design methodologies. The average values are somehow low compared to the target values of reliability (3.0 or 3.5) applied in the calibration stage of the FIB guideline. In this way, the partial safety factors may change in the forthcoming guideline revisions. For this aim, the reliability of strengthening ratio was applied to assess the variation in the average value of the reliability index with different partial safety factors. The performance of parametric study for the factor proved that minimum values of 1.60 and 2.32 are required for target values of reliability (3.0 and 3.5), respectively.

Review of existing techniques and fibre reinforced polymers used for strengthening tubular joints

  • Prashob, P.S;Shashikala, A.P.;Somasundaran, T.P.
    • Structural Monitoring and Maintenance
    • /
    • v.4 no.3
    • /
    • pp.255-268
    • /
    • 2017
  • Fibre reinforced polymers (FRP) are widely used to strengthen steel structures and retrofitting of existing structures due to its excellent properties. This paper reviews the use of carbon fibre reinforced polymer (CFRP) and glass fibre reinforced polymer (GFRP) in strengthening steel and concrete structures. The paper discusses the use of FRP in strengthening of steel bridges, uses of FRP in repairing of corroded structures and the behaviour of different adhesives. The paper then deals with the FRP strengthened hollow sections and the different failure experienced. The paper then reviewed the current state of art used in strengthening tubular structures and focusing on FRP in strengthening of joints.

Steel and FRP double-tube confined RAC columns under compression: Comparative study and stress-strain model

  • Xiong, Ming-Xiang;Chen, Guangming;Long, Yue-Ling;Cui, Hairui;Liu, Yaoming
    • Steel and Composite Structures
    • /
    • v.43 no.2
    • /
    • pp.257-270
    • /
    • 2022
  • Recycled aggregate concrete (RAC) is rarely used in load-carrying structural members. To widen its structural application, the compressive behavior of a promising type of composite column, steel-fiber reinforced polymer (FRP) double-tube confined RAC column, has been experimentally and analytically investigated in this study. The objectives are the different performance of such columns from their counterparts using natural aggregate concrete (NAC) and the different mechanisms of the double-tube and single-tube confined concrete. The single-tube confined concrete refers to that in concrete-filled steel tubular (CFST) columns and concrete-filled FRP tubular (CFFT) columns. The test results showed that the use of recycled coarse aggregates (RCA) affected the axial load-strain response in terms of deformation capacity but such effect could be eliminated with the increasing confinement. The composite effect can be triggered by the double confinement of the steel and carbon FRP (CFRP) tubes but not by the steel and polyethylene terephthalate (PET) FRP tubes. The proposed analysis-oriented stress-strain model is capable to capture the load-deformation history of such steel-FRP double-tube confined concrete columns under axial compression.

KSTAR Superconducting Magnet Supporting Post Prototype Manufacturing and Structural Load Test (KSTAR 초전도자석 지지각 시작품재작 및 구조시험)

  • 허남일;이영신
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 2001
  • A magnet supporting post installed between the lower TF coil tooled by 4.5 K supercritical helium and the cryostat base is one of the most important components of the superconducting magnet supporting structure for KSTAR Tokamak. This structure should be flexible to absorb thermal shrink of the magnet and also should be rigid to support the magnet weight and the Plasma disruptions load. The Post was designed with stainless steel 316LN and CFRP that have low thermal conductivity and high structural strength at low temperature. In order to verify the possibility of fabrication and the structural safety. a whole scale prototype of the KSTAR magnet supporting post was manufactured and tested. Static and compressive cyclic load tests under the maximum Plasma vertical disruption load and the magnet dead weight were performed. The teat results showed that the magnet supporting post of KSTAR Tokamak was possible to manufacture and structurally rigid.

  • PDF

Flexural Behavior of RC Beams Strengthened with Near Surface Mounted Prestressed FRP (프리스트레스를 도입한 표면매립 FRP 보강보의 휨 거동)

  • Park Jae Hyun;Hong Sung Nam;Park Sun Kyu;Jung Woo Tai;Park Jong Sup;Park Young Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.157-160
    • /
    • 2005
  • This paper presents the results of a study on improvement in flexure capacities of RC beams strenthened with near surface mounted prestressed CFRP rod and plate. Experimental variables include type of CFRP, prestressing level and existence of MI(Mechanical Interlocking). Tests show that prestressed beams exhibit a higher crack-load as well as a higher steel-yielding load compared to no-prestressed strengthened beams.

  • PDF

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.

Development of Fitting Process for Extra Long Stainless/Composite Material Pipes (초장축 스테인레스/복합재료 파이프의 피팅 공정 개발)

  • Park, S.H.;Lee, C.M.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.2
    • /
    • pp.77-82
    • /
    • 2008
  • Rubbing-roller is used for manufacturing liquid crystal display, and static displacement of the rubbing-roller becomes bigger as length of the rubbing roller made of aluminum is getting longer. Therefore, material of the rubbing-roller is changed from aluminum to CFRP(Carbon Fiber Reinforced plastic). Recently thermal spraying is applied to manufacturing process of long rubbing-roller. The thermal spraying has disadvantages such as increment of manufacturing time and fraction defective caused by density of stainless steel particle. In this study, fitting process by drawing was suggested and FEM analysis with Tsai-Wu failure theory and fitting experiments are carried out to find adequate shrink allowance. The suggested shrink allowance gives proper adhesive force, and CFRP failure is not occurred. Furthermore, the fitting process is applied to long rubbing-roller and availability of the fitting process is studied by measurement of roundness, straightness and shear strength.

Analyze of the interfacial stress in reinforced concrete beams strengthened with externally bonded CFRP plate

  • Hadji, Lazreg;Daouadji, T. Hassaine;Meziane, M. Ait Amar;Bedia, E.A. Adda
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.413-429
    • /
    • 2016
  • A theoretical method to predict the interfacial stresses in the adhesive layer of reinforced concrete beams strengthened with externally bonded carbon fiber-reinforced polymer (CFRP) plate is presented. The analysis provides efficient calculations for both shear and normal interfacial stresses in reinforced concrete beams strengthened with composite plates, and accounts for various effects of Poisson's ratio and Young's modulus of adhesive. Such interfacial stresses play a fundamental role in the mechanics of plated beams, because they can produce a sudden and premature failure. The analysis is based on equilibrium and deformations compatibility approach developed by Tounsi. In the present theoretical analysis, the adherend shear deformations are taken into account by assuming a parabolic shear stress through the thickness of both the reinforced concrete beam and bonded plate. The paper is concluded with a summary and recommendations for the design of the strengthened beam.

One-Sided Nondestructive Evaluation of CFRP Composites By Using Ultrasonic Sound (초음파를 이용한 CFRP 복합재의 일방향 비파괴 평가)

  • Im, Kwang-Hee;Zhang, Gui-Lin;Choi, Sung-Rok;Ye, Chang-Hee;Ryu, Je-Sung;Lim, Soo-Hwan;Han, Min-Gui;Hsu, David K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.47-52
    • /
    • 2011
  • It is well known that stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences their properties. Ultrasonic NDE of composite laminates is often based on the backwall echoes of the sample. A pair of such transducers was mounted in a holder in a nose-to-nose fashion to be used as a scanning probe on composites. Miniature potted angle beam transducers were used (Rayleigh waves in steel) on solid laminates of composites. Experiments were performed to understand the behavior of the transducers and the nature of the waves generated in the composite (mode, wave speed, angle of refraction). C-scan images of flaws and impact damage were then produced by combining the pitch-catch probe with a portable manual scanner known as the Generic Scanner ("GenScan"). The pitch-catch signal was found to be more sensitive than normal incidence backwall echo of longitudinal wave to fiber orientation of the CFRP composites, including low level porosity, ply waviness, and cracks. Therefore, it is found that the experimentally Rayleigh wave variation of pitch-catch ultrasonic signal was consistent with numerical results and one-side ultrasonic measurement might be very useful to detect the defects.