• 제목/요약/키워드: steel structures

검색결과 6,107건 처리시간 0.023초

Application of Steel-tubed Concrete Structures in High-rise Buildings

  • Zhou, Xuhong;Liu, Jiepeng
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.161-167
    • /
    • 2019
  • Making full use of material strength, maintaining sufficient ductility of structural components, and ensuring simple and robust connections are crucial to the development of steel-concrete composite structures. The steel-tubed concrete structure uses thin-walled steel tube to provide confinement, so that the strength and ductility of the concrete core are improved. Meanwhile, the thin-walled steel tube is terminated at the beam-column joint to avoid the local buckling problem and simplify the connections between steel tube and RC members. A brief overview of the development of steel-tubed concrete structures is presented. Through the discussion on the structural behavior of steel-tubed concrete and the introduction of typical practical projects, the prospects for future research are highlighted.

가소성 선형 성형 폭약 국산 시제품에 의한 철골구조물 절단실험연구 (Experimental Study on the Cutting Effect of Domestic Flexible Linear Shapes Chargers Steel Structure)

  • 임한욱;박근순
    • 산업기술연구
    • /
    • 제24권B호
    • /
    • pp.19-29
    • /
    • 2004
  • The demand for demolition of steel structures is recently increasing in Korea. Most of flexible linear-shaped charges(FLSC) for steel demolition are now imported from foreign countries. Some basic experiments have been studied to determine the optimum parameters of design for domestic development of FLSC. Domestic FLSC were used to check cutting of steel structures and other materials in this study. The result shows that domestic FLSC is very effective to cut steel structures.

  • PDF

1930-40년대 부산·경상지역의 근대 역사문화유산에 사용된 강재의 재료적 특성 (Material Properties of Structural Steel used in Modern Historical Heritage of Busan and Gyeongsang in the 1930-1940s)

  • 안재철;송종목
    • 건축역사연구
    • /
    • 제23권6호
    • /
    • pp.39-46
    • /
    • 2014
  • In this study, we evaluated the chemical and physical properties of structural steel, which is the most basic material for steel structures and reinforcement concrete structures in modern period. We theorized the technical data for the research of technical history of modern heritage structures by analyzing the product system and its quality control of structural steel used in modern historical heritages. The results of this study are as follow; first, the rounded bars were used in most of modern heritage structures. But in the case of Waegwan railroad bridge, the deformed bars were used in spit of not using in Japan after the great earthquake of Kantou. Second, the structural steel was good in terms of quality control, but It has brittle properties because it was not manufactured by heat treatment process.

Numerical modelling and codification of imperfections for cold-formed steel members analysis

  • Dubina, Dan;Ungureanu, Viorel;Rondal, Jacques
    • Steel and Composite Structures
    • /
    • 제5권6호
    • /
    • pp.515-533
    • /
    • 2005
  • Buckling and post-buckling of cold-formed steel members are rather difficult to predict due to material and geometrical non-linearity. However, numerical techniques have reached a level of maturity such that many are now successfully undertaking ultimate strength analysis of cold-formed steel members. In numerical non-linear analysis, both geometrical and material imperfections, have to be estimated and properly used. They must be codified in terms of shape and magnitude. The presented paper represents a state-of-art report, including relevant results obtained by the authors and collected from literature, on that problem.

Pseudo plastic zone analysis of steel frame structures comprising non-compact sections

  • Avery, P.;Mahendran, M.
    • Structural Engineering and Mechanics
    • /
    • 제10권4호
    • /
    • pp.371-392
    • /
    • 2000
  • Application of "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A concentrated plasticity method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in this paper. The pseudo plastic zone method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established by comparison with a comprehensive range of analytical benchmark frame solutions. The pseudo plastic zone method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.

A Fiber Model Based on Secondary Development of ABAQUS for Elastic-Plastic Analysis

  • Shi, Yan-Li;Li, Hua-Wei;Wang, Wen-Da;Hou, Chao
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1560-1576
    • /
    • 2018
  • With the aim to provide an efficient platform for the elastic-plastic analysis of steel structures, reinforced concrete (RC) structures and steel-concrete composite structures, a program iFiberLUT based on the fiber model was developed within the framework of ABAQUS. This program contains an ABAQUS Fiber Generator which can automatically divide the beam and column cross sections into fiber sections, and a material library which includes several concrete and steel uniaxial material models. The range of applications of iFiberLUT is introduced and its feasibility is verified through previously reported test data of individual structural members as well as planar steel frames, RC frames and composite frames subjected to various loadings. The simulation results indicate that the developed program is able to achieve high calculation accuracy and favorable convergence within a wide range of applications.

Optimum distribution of steel frame assembly for seismic retrofit of framed structures

  • Michael Adane;Seungho Chun;Jinkoo Kim
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.337-345
    • /
    • 2024
  • This research proposed a particle swarm optimization (PSO) based seismic retrofit design of moment frame structures using a steel frame assembly. Two full scale specimens of the steel frame assembly with different corner details were attached to one-story RC frames for seismic retrofit, and the lateral load resisting capacities of the retrofitted frames subjected to cyclic loads were compared with those of a bare RC frame. The open source software framework Opensees was used to develop an analytical model for validating the experimental results. The developed analytical model and the optimization scheme were applied to a case study structure for economic seismic retrofit design, and its seismic performance was assessed before and after the retrofit. The results show that the developed steel frame assembly was effective in increasing seismic load resisting capability of the structure, and the PSO algorithm could be applied as convenient optimization tool for seismic retrofit design of structures.

강관 토목구조물이 설치된 지열 히트펌프 시스템의 냉방 성능 평가 (Evaluation on Cooling Performance of Ground Source Heat Pump System Equipped with Steel-pipe Civil Structures)

  • 이석재;양정훈;최항석
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.14-22
    • /
    • 2023
  • Steel-pipe civil structures, including steel-pipe energy piles and cast-in-place piles (CIPs), utilize steel pipes as their primary reinforcements. These steel pipes facilitate the circulation of a working fluid through their annular crosssection, enabling heat exchange with the surrounding ground formation. In this study, the cooling performance of a ground source heat pump (GSHP) system that incorporated steel-pipe civil structures was investigated to assess their applicability. First of all, the thermal performance test was conducted with steel-pipe CIPs to evaluate the average heat exchange amount. Subsequently, a GSHP system was designed and implemented within an office container, considering the various types of steel-pipe civil structures. During the performance evaluation tests, parameters such as the coefficient of performance (COP) and entering water temperature (EWT) were closely monitored. The outcomes indicated an average COP of 3.74 for the GSHP system and the EWT remained relatively stable throughout the tests. Consequently, the GSPH system demonstrated its capability to consistently provide a sufficient heat source, even during periods of high cooling thermal demand, by utilzing the steel-pipe civil structures.

Comparison of the seismic performance of Reinforced Concrete-Steel (RCS) frames with steel and reinforced concrete moment frames in low, mid, and high-rise structures

  • Jalal Ghezeljeh;Seyed Rasoul Mirghaderi;Sina Kavei
    • Steel and Composite Structures
    • /
    • 제50권3호
    • /
    • pp.249-263
    • /
    • 2024
  • This article presents a comparative analysis of seismic behavior in steel-beam reinforced concrete column (RCS) frames versus steel and reinforced concrete frames. The study evaluates the seismic response and collapse behavior of RCS frames of varying heights through nonlinear modeling. RCS, steel, and reinforced concrete special moment frames are considered in three height categories: 5, 10, and 20 stories. Two-dimensional frames are extracted from the three-dimensional structures, and nonlinear static analyses are conducted in the OpenSEES software to evaluate seismic response in post-yield regions. Incremental dynamic analysis is then performed on models, and collapse conditions are compared using fragility curves. Research findings indicate that the seismic intensity index in steel frames is 1.35 times greater than in RCS frames and 1.14 times greater than in reinforced concrete frames. As the number of stories increases, RCS frames exhibit more favorable collapse behavior compared to reinforced concrete frames. RCS frames demonstrate stable behavior and maintain capacity at high displacement levels, with uniform drift curves and lower damage levels compared to steel and reinforced concrete frames. Steel frames show superior strength and ductility, particularly in taller structures. RCS frames outperform reinforced concrete frames, displaying improved collapse behavior and higher capacity. Incremental Dynamic Analysis results confirm satisfactory collapse capacity for RCS frames. Steel frames collapse at higher intensity levels but perform better overall. RCS frames have a higher collapse capacity than reinforced concrete frames. Fragility curves show a lower likelihood of collapse for steel structures, while RCS frames perform better with an increase in the number of stories.

Influence of steel-concrete interaction in dissipative zones of frames: I - Experimental study

  • Ciutina, Adrian;Dubina, Dan;Danku, Gelu
    • Steel and Composite Structures
    • /
    • 제15권3호
    • /
    • pp.299-322
    • /
    • 2013
  • In the case of seismic-resistant composite dual moment resisting and eccentrically braced frames, the current design practice is to avoid the disposition of shear connectors in the expected plastic zones, and consequently to consider a symmetric moment or shear plastic hinges, which occur only in the steel beam or link. Even without connectors, the real behaviour of the hinge may be different from the symmetric assumption, since the reinforced concrete slab is connected to the steel element close to the hinge locations, and also due to contact friction between the concrete slab and the steel element. The paper presents the results and conclusions of experimental tests on composite portal eccentrically braced frames and beam-to-column moment-resisting joints, carried out within the CEMSIG Research Centre of the Politehnica University of Timisoara, in order to check the validity of the assumption stated above. Reference steel and composite specimens with and without connectors in the plastic zones have been tested under monotonic and cyclic seismic type loading.