• 제목/요약/키워드: steel plating

검색결과 166건 처리시간 0.023초

중성자 조사에 따른 Ni도금피복재에서의 He발생량평가 (He Generation Evaluation on Electrodeposited Ni After Neutron Exposure)

  • 황성식;권준현;김동진;김성우
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.308-314
    • /
    • 2021
  • Neutron dose level at bottom head of a reactor pressure vessel (RPV) was calculated using reactor vessel neutron transport for a Korean nuclear power plant A. At 34 EFPY with a 40-year (2042) design life after plating repair, irradiation fast neutron effect was 6.6x1015 n/cm2. As helium(He) gas can be generated by Ni only at 1/106 level of 5 × 1021 n/cm2, He generation possibility in the Ni plating layer is very little during 40 years of operation (2042, 34 EFPY). Thermal neutrons can significantly affect the generation of He from Ni metal. At 10 years after a repair, He can be generated at a level of about 0.06 appm, a level that can add general welding repair without any consideration. After 40 years of repair, 9.8 appm of He may be generated. Although this is a rather high value, it is within the range of 0.1 to 10 appm when welding repair can be applied. Clad repair by Ni electroplating technology is expected to greatly improve the operation efficiency by improving the safety and shortening the maintenance period of the nuclear power plant.

이온 플레이팅법으로 제조한 (Ti$_{1-x}$Cr$_{x}$)N 박막의 마모특성에 관한 연구 (Wear properties of (Ti$_{1-x}$Cr$_{x}$)N coatings deposited by ion-plating method)

  • 이광희;박찬홍;이정중
    • 한국표면공학회지
    • /
    • 제34권2호
    • /
    • pp.125-134
    • /
    • 2001
  • ($Ti_{1-x}$ $Cr_{x}$ )N coatings were deposited by an ion-plating method in a reactor with two separate metal sources, Ti and Cr. Ti was evaporated using an electron beam, while Cr evaporation was carried out by resistant heating. The Ti and Cr concentrations in the coatings were controlled by the Ti and Cr evaporation ratio. The coating hardness increased with increasing the Cr content(x) and showed a maximum value of 6,000 HK at around x=0.8. The critical load of the coatings, measured by the scratch test, was around 30 N. The wear resistance properties of the ($Ti_{1-x}$$Cr_{ x}$)N coatings were evaluated using a CSEM pin-on-disk type tribometer. A Cr-steel ball as well as a SiC ball, which had hardness values of 590 HK and 2,600 HK respectively, were used as the pin. After the wear test, the surface morphology, roughness and the concentration of the coatings were investigated, with the main focus being on the effect of wear debris and the transferred layer on the wear behavior.

  • PDF

36개월간 국내 옥외폭로시험에 따른 아연도강의 부식거동 (Corrosion Behavior of Galvanized Steels with Outdoor Exposure Test in Korea for 36 Months)

  • 김기태;김영식
    • Corrosion Science and Technology
    • /
    • 제17권5호
    • /
    • pp.231-241
    • /
    • 2018
  • Atmospheric corrosion is generally an electrochemical degradation process of metal. It can be caused by various corrosion factors of atmospheric component, weather, and air pollutants. Moisture, particles of sea salts, and sulfur dioxide are major factors in atmospheric corrosion. Galvanizing coating is one of the most efficient ways to protect iron from corrosion by zinc plating on the surface of the iron. Galvanized steels are being widely used in automobiles, building structures, roofing, and other industrial structures due to their high corrosion resistance compared to bare iron. Atmospheric corrosion of galvanized steel has shown complex corrosion behavior depending on coating process, coating thickness, atmospheric environment, and air pollutants. In addition, different types and kinds of corrosion products can be produced depending on the environment. Lifespan of galvanized steels is also affected by the environment. Therefore, the objective of this study was to determine the corrosion behavior of galvanized steel under atmospheric corrosion at six locations in Korea. When the exposure time was increased, content of zinc from GA surface decreased while contents of iron and oxygen tended to increase. On the other hand, content of iron was constant even after 36 months of exposure of GI.

강 기판위에 아크이온 플레이팅된 CrN박막의 산화 (The Oxidation of CrN Films Arc-ion Plated on a Steel Substrate)

  • 이동복;이영찬
    • 한국재료학회지
    • /
    • 제11권4호
    • /
    • pp.324-328
    • /
    • 2001
  • 아크이온 플레이팅 장치를 이용하여 STD61강 기판 위에 이온질화 전처리를 행하거나 하지 않은 후, CrN 박막을 증착하고, 대기중 $700~900^{\circ}C$의 온도에서 40시간동안 이들에 대한 산화거동을 연구하였다. 산화거동은 열중량분석기, X선회절기, EDS, SEM을 이용하여 조사하였다. 증착된 CrN박막은 CrN과 $Cr_2$N의 두 상으로 구성되어 있었다. CrN박막은 보호적 $Cr_2$O$_3$층을 형성하여 기판을 산화로부터 보호하였다. 이온질화처리는 CrN박막의 내산화성에 영향을 주지 않았다.

  • PDF

하이브리드 코팅시스템에 의해 제조된 Ti-Si-N 코팅막의 상대재에 대한 마모거동 연구 (Tribological Behaviors Against Counterpart Materials of Ti-Si-N Coating Layers Prepared by a Hybrid Coating System)

  • 박옥남;박종현;윤석영;권식철;김광호
    • 한국표면공학회지
    • /
    • 제36권2호
    • /
    • pp.116-121
    • /
    • 2003
  • Ti-Si-N coating layers were deposited onto WC-Co substrates by a hybrid system of arc ion plating (AIP) and sputtering techniques. The tribological behaviors of Ti-Si-N coating layers with various Si contents were investigated by the dry sliding wear experiments, which were conducted at three different sliding speeds, 0.1, 0.3, 0.5 m/s, against the steel and alumina balls. In the case of steel ball, the average friction coefficient slightly decreased with increasing the sliding speed regardless of Si content due to adhesive wear behavior between coating layer and steel ball. At constant sliding speed, the average friction coefficient decreased with increase of Si content. On the contrary, in the case of alumina ball, the average friction coefficient increased with increasing the sliding speed regardless of Si content, indicating that the abrasive wear behavior was more dominant when the coating layers slide against alumina ball. Through these experimental results, it was found that the tribological behaviors of Ti-Si-N coating layers were effected by factors such as Si content, sliding speed, and kinds of counterpart materials rather than the hardness of coating layer.

제조업 산업장의 소음환경과 직업성 난청에 관한 조사연구 (A Study on the noise working environment and occupational hearing impairment in the manufactoring industries)

  • 이채언;이종태;손혜숙;문덕환;조병만;김성천;배기택;김용완
    • 월간산업보건
    • /
    • 통권5호
    • /
    • pp.4-15
    • /
    • 1988
  • In order to proffer the fundamental data for the better working environment and the effective establishment of hearing conservation program on workers exposed to industrial noise, author assessed noise levels on the 42 noisy processes among 84 manufactures of 9 industries and measured noise gearing loss by the type of industries on 3,104 workers at these noisy processes from March, 1986 to Februry, 1987. The results were summarized as follows: 1. The averge of A-weight sound level of 23 processes(54.8%) and the avergae of sound level at each octave band of 14 processes(33.3%) exceeded the permissible exposure limits in 8 hours per day. 2. The noise level was the highest in process of cocking of ship building(109.1dBA), and followed by plating of steel rolling(104.3dBA), rivet of manufacture of motor vehicles(102.5dBA), shot of ship building(98.5dBA), aciding(95.7BA) and steel tubing(95.0dBA) of steel rolling, weaving of textiles(95.0dBA). 3. The permissible exposure time for the average of sound level at each octave band was only 30 minutes in the process of cocking of ship building, plating of steel rolling and rivet of manufacture of motor vehicles. 4. As a result of audiometric examination in 3,104 workers, the rate of hearing loss over 50dB at 4,000Hz was 7.3%(227 workers) and the rate of hearing loss over 41dB at 60average method was 2.9%(89 workers). 5. The prevalence of occupational hearing loss in ship building and manufacture of motor vehicle was 5.2% and it was the highest among prevalence of these 9 industries. 6. As a result of this suvery, the noise control and gearing conservation program were required especially in the industry of ship building and manufacture of motor vehicle.

  • PDF

수소 장입 장치를 활용한 액체수소 저장시스템 강재의 CTOD 시험 분석 (Analysis of CTOD Tests on Steels for Liquefied Hydrogen Storage Systems Using Hydrogen Charging Apparatus)

  • 성기영;김정현;이정희;이정원
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.875-884
    • /
    • 2023
  • Hydrogen infiltration into metals has been reported to induce alterations in their mechanical properties under load. In this study, we conducted CTOD (Crack Tip Opening Displacement) tests on steel specimens designed for use in liquid hydrogen storage systems. Electrochemical hydrogen charging was performed using both FCC series austenitic stainless steel and BCC series structural steel specimens, while CTOD testing was carried out using a 500kN-class material testing machine. Results indicate a notable divergence in behavior: SS400 test samples exhibited a higher susceptibility to failure compared to austenitic stainless steel counterparts, whereas SUS 316L test samples displayed minimal changes in displacement and maximum load due to hydrogen charging. However, SEM (Scanning Electron Microscopy) analysis results presented challenges in clearly explaining the mechanical degradation phenomenon in the tested materials. This study's resultant database holds significant promise for enhancing the safety design of liquid hydrogen storage systems, providing invaluable insights into the performance of various steel alloys under the influence of hydrogen embrittlement.

레진으로 접착 보강한 강재보의 거동 (Experimental and Analytical Study on the Steel Beam bonded with CFRP Strip)

  • Sung, Ikhyun
    • 한국재난정보학회 논문집
    • /
    • 제13권1호
    • /
    • pp.81-88
    • /
    • 2017
  • 이 논문에서는 강재 보와 보강을 위하여 부착한 탄소섬유판의 동일거동을 분석하기 위하여 시험과 유한요소해석을 수행하고, 시험 및 해석 결과를 이용한 분석을 실시하였다. 현재 국내외의 연구에서는 복합재료를 사용한 보수 보강 복구에 대한 사용검토가 많이 연구되어지는 실정에서 섬유보강 복합재료는 얇고 강도가 좋으며 가벼워 구조물의 보강 시에 사하중의 증가를 발생시키지 않고 부재의 치수 증가에도 영향이 없어 매우 유용한 재료로 부각된다. 그러나 노후화에 따른 부착력 저하 등의 문제와 경제성 및 설계상의 어려움으로 사용이 극히 제한적인 부분이다. 이 연구에서는 탄소섬유판이 부착된 단순한 강재보의 성능을 평가하였으며, 부착성능 측면에서는 양호한 사용성능을 가지는 것으로 나타났다. 향후 노후화에 대한 검토가 수행된다면 실제 구조물에 대한 적용에도 문제가 없을 것으로 판단된다.

Study on Reusable Electrodes for Personal Electrocardiography

  • Kim, Jonghoon;Yoon, Gilwon
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.340-344
    • /
    • 2018
  • Electrodes are an important part of electrocardiography (ECG); disposable electrodes have been extensively used. However, personal ECG monitoring devices for Internet of Things applications require reusable electrodes. As there have been no systematic studies on the characteristics of reusable electrodes to date, we conducted this study to assess the performance and feasibility of electrodes with different materials. We built reusable electrodes using twelve different metallic materials, including commonly used copper, silver, zinc, plating materials, chemically inert titanium, stainless steel, and aluminum. Each electrode was fabricated to a size of $5{\times}10mm$. Their characteristics such as offset, baseline drift, stabilization time, and chemical inertness were compared. A personal ECG monitoring system was used to test the manufactured electrodes. The performances of the Ag, Cu, and Zn electrodes were better than the performances of other electrodes. However, these materials may not be used owing to the chemical changes that occur when the electrodes are in contact with the skin, such as discoloration and corrosion, which deteriorate their electrical characteristics. Titanium, stainless steel, and aluminum are chemically stable. The titanium electrode showed the best performance among the three, and it is our recommendation as a material for manufacturing reusable electrodes.

세라믹 코팅된 1Cr-1Mo-0.25V강의 피로균열성장 특성 (Fatigue crack growth properties of ceramic coated 1Cr-1Mo-0.25V steel)

  • 서창민;김경렬
    • 대한기계학회논문집A
    • /
    • 제21권10호
    • /
    • pp.1674-1682
    • /
    • 1997
  • Fatigue tests were performed to investigate the effect of ceramic coatings as in TiN and TiCN on fatigue crack growth properties of ceramic coated 1Cr-1Mo-0.25V steel with different coating thickness in laboratory air conditions. The experimental results are described with respect to a Paris equation, da/dN=C(.DELTA.K)$^{m}$ , where the crack growth rate of coated specimens provided as similar growth rate as that of the uncoated specimen regardless of coating thickness. Furthermore, it was observed that the type of coating layer had virtually no effect on crack growth rate in the full region of stress intensity factor range. And it was also appeared that the final crack length of TiCN coated specimens was short compared to that of TiN coated, and the substrate specimens, in which it was inferred due to lowering the toughness of coated material from high hardness of TiCN coating layer itself.