• 제목/요약/키워드: steel plates

검색결과 1,478건 처리시간 0.031초

Full-scale tests and finite element analysis of arched corrugated steel roof under static loads

  • Wang, X.P.;Jiang, C.R.;Li, G.Q.;Wang, S.Y.
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.339-354
    • /
    • 2007
  • Arched Corrugated Steel Roof (ACSR) is a kind of thin-walled steel shell, composing of arched panels with transverse small corrugations. Four full-scale W666 ACSR samples with 18m and 30m span were tested under full and half span static vertical uniform loads. Displacement, bearing capacities and failure modes of the four samples were measured. The web and bottom flange in ACSR with transverse small corrugations are simplified to anisotropic curved plates, and the equivalent tensile modulus, shear modulus and Poisson's ratio of 18m span ACSR were measured. Two 18 m-span W666 ACSR samples were analyzed with the Finite Element Analysis program ABAQUS. Base on the tests, the limit bearing capacity of ACSR is low, and for half span loading, it is 74-75% compared with the full span loading. When the testing load approached to the limit value, the bottom flange at the sample's bulge place locally buckled first, and then the whole arched roof collapsed suddenly. If the vertical loads apply along the full span, the deformation shape is symmetric, but the overall failure mode is asymmetric. For half span vertical loading, the deformation shape and the overall failure mode of the structure are asymmetric. The ACSR displacement under the vertical loads is large and the structural stiffness is low. There is a little difference between the FEM analysis results and testing data, showing the simplify method of small corrugations in ACSR and the building techniques of FEM models are rational and useful.

압연 및 용접방향이 같은 맞대기 용접강판의 하중방향에 따른 피로균열 진전특성 (Characteristics of Fatigue Crack Propagations with Respect to Loading Directions in Butt-Welded Steel Plates with the Same Direction of Rolling and Welding Bead)

  • 이용복;김성엽;오병덕
    • Journal of Welding and Joining
    • /
    • 제23권6호
    • /
    • pp.37-42
    • /
    • 2005
  • Most of the welding steel plate structures have complicated mechanical problems such as rolling directional characteristics and residual stresses caused by manufacturing process. For the enhancement of reliability and safety in those structures, therefore, a systematic investigation is required. SS400 steel plate used for common structures was selected and welded by FCAW butt-welding process for this study, and then it was studied experimently about characteristics of fatigue crack propagations with respect to rolling direction and welding residual stress of welded steel plates. When the angles between rolling direction and tensile loading direction in base material are increased, their ultimate strength not show a significant difference, but yielding strength are increased and elongations are decreased uniformly. It is also shown that fatigue crack growth rate can be increased from those results. When the angles between welding bead direction and loading direction in welded material are increase, fatigue crack growth rate of them are decreased and influenced uniformly according to the conditions of residual stress distribution. In these results, it is shown that the welded steel plate structures are needed to harmonize distributed welding residual stress, rolling direction and loading direction fur the improvement of safety and endurance in manufacture of their structures.

제형 및 사인형 주름 강판의 초기 불완전 형상을 고려한 전단 좌굴 특성 비교 (A Comparitive Study on the Shear Buckling Characteristics of Trapezoidal and Sinusoidal Corrugated Steel Plate Considering Initial Imperfection)

  • 서건호;손수덕;이승재
    • 한국공간구조학회논문집
    • /
    • 제21권4호
    • /
    • pp.57-64
    • /
    • 2021
  • This paper conducted a comparative analysis of the shear buckling characteristics of trapezoidal and sinusoidal corrugated steel plates considering of their initial imperfection. Initial imperfection refers to the state where the shape of the corrugated plate is initially not perfect. As such, an initially imperfect shape was assumed using the eigen buckling mode. To calculate the buckling stress of corrugated steel plates, the linear buckling analysis used a boundary condition which was applied to the plate buckling analysis. For the comparison of trapezoidal and sinusoidal corrugation, the shape parameters were assumed using the case where the length and slope of each corrugation were the same, and the initial imperfection was considered to be from 0.1% to 5% based on the length of the steel plate. Here, for the buckling analysis, ANSYS, a commercial FEA program, was used. From the results of buckling analysis, the effect of overall initial imperfection showed that the larger the initial imperfection, the lower the buckling stress. However, in the very thin model, interaction or local buckling was dominant in the perfect shape, and in this case, the buckling stress did not decrease. Besides, the sinusoidal model showed higher buckling stress than the trapezoidal one, and the two corrugation shapes decreased in a similar way.

Hysteresis performance of earthquake-damaged resilient RAC shear walls retrofitted with CFRP strips and steel plates

  • Jianwei Zhang;Siyuan Wang;Man Zhang;Yuping Sun;Hongwei Wang
    • Steel and Composite Structures
    • /
    • 제52권3호
    • /
    • pp.357-376
    • /
    • 2024
  • In this paper, weakly bonded ultra-high-strength steel bars (UHSS) were used as longitudinal reinforcement in recycled aggregate concrete shear walls to achieve resilient performance. The study evaluated the repairability and hysteresis performance of shear walls before and after retrofitting. Quasi-static tests were performed on recycled aggregate concrete (RAC) and steel fiber reinforced recycled aggregate concrete (FRAC) shear walls to investigate the reparability of resilient shear walls when loaded to 1% drift ratio. Results showed that shear walls exhibited drift-hardening properties. The maximum residual drift ratio and residual crack width at 1% drift ratio were 0.107% and 0.01mm, respectively, which were within the repairable limits. Subsequently, shear walls were retrofitted with bonded X-shaped CFRP strips and steel plates wrapped at the bottom and retested. Except for a slight reduction in initial stiffness, earthquake-damaged resilient shear walls retrofitted with a composite method still had satisfactory hysteresis performance. A revised damage assessment index D, has been proposed to assess of damage degree. Moreover, finite-element analysis for the shear wall before and after retrofit retrofitting was established in OpenSees and verified with experimental results. The finite element results and test results were in good agreement. Finally, parametric analysis was performed.

리브 제원을 고려한 평강 리브 보강판의 직교이방성 휨 강성 수정 계수 (The Modified Coefficient of the Orthotropic Flexural Rigidity for Stiffened Plates with Rectangular Ribs Considering the Dimensions of Ribs)

  • 주석범
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.161-170
    • /
    • 2007
  • 본 연구에서는 직교이방성 판 해석의 정확도 문제를 개선하기 위하여 평강 리브를 갖는 보강판에 대하여 리브 제원을 고려한 직교이방성 휨 강성 수정 계수를 제안하고자 하였다. 이를 위하여 먼저, 직교이방성 휨 강성과 최대 처짐에 대하여 보강판 제원에 따른 민감도 분석을 실시하였으며, 보강판의 직교이방성 휨 강성 수정 계수에 대한 매개변수 연구를 수행하였다. 연구 결과, 수정 계수의 비율은 판 두께와 상관없이 리브 높이, 간격, 두께별로 하나의 함수로 표현 가능함을 알 수 있었으며, 이러한 수정 계수의 비율 함수로부터 간편하게 수정 휨 강성을 산정할 수 있음을 알 수 있었다. 지지 조건, 변장비, 리브 배치 및 재하 크기가 다른 여러 가지 보강판에 계수 함수를 적용한 결과, 참고 문헌에 비하여 직교이방성 판 해석의 정확도가 향상됨을 알 수 있었다. 따라서, 본 연구에서 제안한 계수 함수식을 사용하면 평강 리브를 갖는 보강판의 직교이방성 판 해석 시 간편하게 상당한 정확도의 결과를 얻을 수 있을 것으로 판단된다.

농어촌 지역 RC건축물 보의 철판망 보강에 관한 실험 연구 (An Experimental Study on Beam Strengthening of RC Buildings with Expanded Steel Plates in Rural Area)

  • 김윤일;홍시헌
    • 한국농촌건축학회논문집
    • /
    • 제7권1호
    • /
    • pp.121-128
    • /
    • 2005
  • This experimental study was conducted to investigate beam strengthening of RC buildings with expended steel plate(ESP) in rural area. Nine test specimens were manufactured, whose variables were tensile steel ratio and the amount and the shape of expanded steel plate. The test results indicated that strengthened beams with ESP showed the improvement of flexural strength of 50%~90%, and the beam strengthening of U type was excellent for shear reinforcement as well as flexural reinforcement, more over, the honeycomb shape of ESP and anchor bolts for development of ESP were very effective.

  • PDF

대공간 교육시설 축조를 위한 프리스트레스트 보에 사용되는 접합 강재의 성능평가에 대한 연구 (A Study for Structural Capacity Evaluation of Embedded Steel Plate Connected with Prestressed Concrete Beam to Build Large Space Educational Facilities)

  • 이경훈
    • 교육녹색환경연구
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2011
  • An experimental study to evaluate structural capacity of an embedded plate connected with prestressed concrete beam was performed. Embedded steel plates and prestressed concrete beam were connected with stud-bolts at the ends of concrete beam specimens. About 1,000 kN concentrated load was applied at 450mm away from the end of beam specimen. A 3,000 kN capacity static Oil-jack was used to direct concentrated load. The maximum strain of stud-bolt recorded $90{\times}10^{-6}$(mm/mm) and wide width cracks were not founded. Any falling failures of concrete and large deformations were not founded either between steel plate and prestressed concrete specimen. As a result, construction performance can be improved using this embedded steel plate connection system apply to large space educational facilities.

강재의 유도가열 방법의 수치적 승온 해석 (A Numerical Study on Temperature Profiles of Steel Plates Heated by Induction Heater)

  • 김형진;정원철;조병수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1412-1416
    • /
    • 2003
  • Induction Heaters are commonly used in heating steel strip product, because it can rapidly and efficiently heat steel strip/bar. In this study, a inductive heating model is developed and the predictions are compared with measured temperatures. The temperatures are measured from POSCO thin-slab rolling facility (so called Minimill). Induction heater is installed between reduction unit and holding furnace This induction heater raise the temperature of steel bars from $930^{\circ}C$ to about $1100^{\circ}C$ which gives the required temperature for finishing mill process after holding period at holding furnace. Unlike other simple equation models, this model allows us to predict temperature profiles of sections of steel bars.

  • PDF

熔融알루미늄 鍍金한 鋼板의 機械的 性質에 關한 硏究 (A Study on Mechanical properties of Aluminized Steel Plate)

  • 김석윤;최종술
    • 한국표면공학회지
    • /
    • 제13권2호
    • /
    • pp.81-86
    • /
    • 1980
  • The mechanical properties of aluminized steel were investigated after the JIS SB 41 plates were dipped in molten aluminum bath. (1) The growth rate of iron-aluminum alloy layer was fast in early stage of alumizing, and then gradually decreased with increasing time. However, over the time period above 10 minutes the growth of alloy layer did not occur. (2) The constituent of alloy layer formed on the steel surface was identified to be intermetallic compound of $Fe_2\;Al_5$. (3) The ultimate tensile strength and elongation of aluminized steel showed a nearly constant value over all thickness below about 0.15 mm. However, both properties decreased rapidly in showed a nearly constant value over all thickness above about 0.20 mm. (4) In case of aluminized steel with greater thickness, crack was formed below yield point of base metal, which is considered to be attributed to the alloy layer failure.

  • PDF

Bolted end plate connections for steel reinforced concrete composite structures

  • Li, Xian;Wu, Yuntian;Mao, Weifeng;Xiao, Yan;Anderson, J.C.;Guo, Yurong
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.291-306
    • /
    • 2006
  • In order to improve the constructability and meanwhile ensure excellent seismic behavior, several innovative composite connection details were conceived and studied by the authors. This paper reports experimental results and observations on seismic behavior of steel beam bolted to reinforced concrete column connections (bolted RCS or BRCS). The proposed composite connection details involve post tensioning the end plates of the steel beams to the reinforced concrete or precast concrete columns using high-strength steel rods. A rational design procedure was proposed to assure a ductile behavior of the composite structure. Strut-and-tie model analysis indicates that a bolted composite connection has a favorable stress transfer mechanism. The excellent capacity and behavior were then validated through five full-scale beam to column connection model tests.