• 제목/요약/키워드: steel fiber reinforcement

검색결과 470건 처리시간 0.025초

고강도 강섬유보강콘크리트 보의 전단거동 (Shear Behavior of High-Strength Concrete Beams with Steel Fiber)

  • 갈경완;황진하;이득행;주현진;김강수;조해창
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.65-66
    • /
    • 2010
  • 이 연구에서는 고강도 콘크리트에 강섬유를 혼입했을 경우 강섬유의 전단 보강재로서 효율성을 파악하기 위해 강섬유 혼입률이 0.5%-1.0%인 3개의 강섬유보강 고강도 콘크리트 보와 1개의 고강도 콘크리트 보를 제작하여 전단파괴를 유도한 실험을 수행하였다. 실험결과 강섬유 혼입에 의해 고강도 콘크리트 보의 전단강도가 크게 증가 되었으며 연성적으로 거동하는 것을 알 수 있었다.

  • PDF

강섬유 보강 폴리머 콘크리트의 강도특성 및 휨인성에 관한 연구 (Study on the Strength Characteristics and Flexural Toughness of Steel Fiber Reinforced Polymer Concrete)

  • 김기락;연규석;이윤수
    • 콘크리트학회논문집
    • /
    • 제11권4호
    • /
    • pp.137-145
    • /
    • 1999
  • The use of steel fiber reinforced to improve the strength and flexural toughness of concrete is well known, but reinforcement of polymer concrete with steel fibers has been hardly reported till now. Polymer concrete has high strength, durability and freeze-thaw resistance than that of cement concrete, but it has disadvantage such as low flexural toughness. In this paper, the strength characteristics and flexural toughness of steel fiber reinforced polymer concrete are investigated experimentally with various steel fiber aspect ratios($\ell$/d), and contents(vol.%). As the result, the flexural and splitting tensile strengths and flexural toughness were increased aspect ratio, and reach the maximums at a aspect ratio of 50. The relationship between the compressive, flexural and splitting tensile strength were high. And the relationship between flexural strength and strain energy was approximately linear.

유기 및 무기 섬유로 보강한 포트랜드 시멘트의 물성 연구 (Physical Properties of Organic- and Inorganic-Fiber Reinforced Portlandcement)

  • 장복기;김윤주
    • 한국세라믹학회지
    • /
    • 제41권9호
    • /
    • pp.690-695
    • /
    • 2004
  • 본 연구에서는 무기(강, 아스베스트와 카본) 및 유기(폴리아크릴과 폴리아마이드) 섬유가 포트랜드 시멘트의 물성 보강에 미치는 영향을 조사하였다. 각 시편의 하중-변형 관계도로부터 굽힘강도, 탄성계수, 파괴에너지 및 파괴인성 값을 구하여 서로 비교하였다. 그리고 따로 충격에너지 실험도 수행하였으며 파괴에너지와 비교하였다. 휨강도 개선에는 무기(아스베스트) 섬유보강이 가장 효과적이었으며, 충격에너지의 보강섬유로는 유기(폴리아크릴) 섬유가 가장 좋았다. 한편 강 섬유는 휨 강도와 충격에너지 양자를 동시에 보강하는 데에 가장 적합했다. 또한 강 섬유는 모든 섬유 중에서 가장 높은 파괴에너지와 파괴인성 값을 나타내었다.

순환골재를 사용한 SFRC 보의 전단성능 (Shear Performance on SFRC Beam Using Recycled Coarse Aggregate)

  • 김성은;정재원;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.189-196
    • /
    • 2018
  • 순환골재를 사용한 철근콘크리트 부재에서 휨강도에 비하여 전단성능 저하가 문제점으로 제기되고 있다. 이를 해결하기 위한 방법으로 강섬유를 콘크리트 보강재로 사용할 수 있다. 본 연구에서는 순환골재를 사용한 SFRC 보의 전단실험을 통하여 강도 및 변형 특성을 파악하고자 하였다. 주요 실험변수는 강섬유 혼입률(0, 0.5%, 1%), 순환골재 치환율(0%, 100%), 전단경간비(a/d = 1, 2) 등이다. 실험결과 실험에 의한 전단강도는 강섬유의 혼입률이 증가할수록 전단경간비가 작아질수록 증가하였다. 강섬유 1% 혼입한 순환골재의 경우 일반 골재에 비해 최대전단내력이 1.77~6.25% 증가한 반면에 강섬유 0~0.5% 혼입한 실험체에서는 일반골재에 비해 순환골재가 24.2%~49.2%의 전단강도가 저하되었다. 이를 볼 때 1% 강섬유 보강에 의하여 순환골재 사용에 따른 강도 저하를 방지하는데 크게 기여하는 것을 알 수 있다.

터널라이닝 구조재로서 SFRC 적용에 관한 연구 (Application of SFRC as a lining material in tunnels)

  • 이상근;김동인;조규성
    • 한국터널지하공간학회 논문집
    • /
    • 제3권4호
    • /
    • pp.25-34
    • /
    • 2001
  • 산지가 70%를 차지하고 있는 우리나라 지형특성상 고속도로 건설에 비례하여 터널연장의 증가는 필연적이라 할 수 있다. 본 연구에서는 터널 내,외부의 온도차이에 의한 균열에 저항할 수 있도록 하기위해 터널 입,출구부에 설치되는 철근콘크리트 라이닝의 시공성 및 안전성,경제성을 확보할 수 있는 방안으로 강섬유보강 콘크리트(Steel Fiber Reinforcement Concrete, SFRC)의 적용성에 대해 연구하였다. SFRC의 특징을 조사하고 터널 갱구부 라이닝 구조부재로서 구조해석과 현장 시험시공을 통해 SFRC의 적용방안과 차후 확대 적용을 위한 개선방안을 제시하였다.

  • PDF

강섬유(鋼纖維) 보강(補强)콘크리트보의 전단특성(剪斷特性)에 관한 연구(研究) (A Study on the Shear Properties of Steel Fiber Reinforced Concrete Beams)

  • 문제길;홍익표
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.1-12
    • /
    • 1993
  • 본 논문은 전단철근을 갖지 않는 강섬유보강콘크리트 보의 전단특성을 규명하고 균열전단강도와 극한전단강도를 예측하기 위한 것으로 섬유로 보강된 21개의 보를 포함한 총 36개의 보를 4 series로 나누어 실험을 수행하였다. 실험의 변수는 콘크리트의 강도, 섬유혼입율, 전단지간, 인장철근량 등이며, 실험과정을 통해 파괴형상, 처짐, 전단강도 등을 측정하였다. 실험결과로부터 섬유의 혼입량이 많아지고, 콘크리트의 강도가 커질수록, 그리고 전단지간이 짧아질수록 섬유보강콘크리트 보의 균열 및 극한전단강도가 증가됨을 밝혔다. 또한, 실험결과를 회귀분석하여 균열전단강도와 극한전단강도 추정식을 제안하였다. 제안된 추정식에 의한 계산값과 실험결과를 비교 검토하여 그 상관성을 확인하였다.

  • PDF

Earthquake resistance of structural walls confined by conventional tie hoops and steel fiber reinforced concrete

  • Eom, Taesung;Kang, Sumin;Kim, Okkyue
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.843-859
    • /
    • 2014
  • In the present study, the seismic performance of structural walls with boundary elements confined by conventional tie hoops and steel fiber concrete (SFC) was investigated. Cyclic lateral loading tests on four wall specimens under constant axial load were performed. The primary test parameters considered were the spacing of boundary element transverse reinforcement and the use of steel fiber concrete. Test results showed that the wall specimen with boundary elements complying with ACI 318-11 21.9.6 failed at a high drift ratio of 4.5% due to concrete crushing and re-bar buckling. For the specimens where SFC was selectively used in the plastic hinge region, the spalling and crushing of concrete were substantially alleviated. However, sliding shear failure occurred at the interface of SFC and plain concrete at a moderate drift ratio of 3.0% as tensile plastic strains of longitudinal bars were accumulated during cyclic loading. The behaviors of wall specimens were examined through nonlinear section analysis adopting the stress-strain relationships of confined concrete and SFC.

보강재를 사용한 철근 콘크리트 보의 내력보강에 관한 실험적 연구 (An Experimental Study on Improved Bearing-Capacity of Reinforced Concrete Beam Using Reinforcement Materials)

  • 홍상균;박기철;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.495-500
    • /
    • 1996
  • In this paper, it is the effect of using fiber sheet (Carbon Fiber Sheet & Aramid Fiber Sheet) and Steel Plate for reinforced concrete beam, 25 specimens are tested, 16 specimens for bending capacity and the other are for shear capacity. In the case of bending testing, the kind and quantity of the reinforcement materials, the bondage and the existence of crack were selected as experimental variables. And in the case of shear testing, it is testified the effect of reinforcement with the variables of the method of reinforcement (side type and U type). As a result, using the reinforcement meterials can increase the capacity of bending stress.

  • PDF

철근 콘크리트 보-기둥 외측 접합부에 적용된 강섬유의 효과에 관한 실험연구 (An Experimental Study on the Effects of Steel Fibers used at R/C Exterior Joints)

  • 최기봉;오종한;김재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.188-193
    • /
    • 1998
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of lateral confinement and fiber reinforcement of joint area were investigated. It was concluded ; (1) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by pull-out of hooked bars; and (2) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers. Application of steel fibers to exterior joints seems to be an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in exterior beam-column connections.

  • PDF

Post-peak response analysis of SFRC columns including spalling and buckling

  • Dhakal, Rajesh P.
    • Structural Engineering and Mechanics
    • /
    • 제22권3호
    • /
    • pp.311-330
    • /
    • 2006
  • Standard compression tests of steel fiber reinforced concrete (SFRC) cylinders are conducted to formulate compressive stress versus compressive strain relationship of SFRC. Axial pullout tests of SFRC specimens are also conducted to explore its tensile stress strain relationship. Cover concrete spalling and reinforcement buckling models developed originally for normal reinforced concrete are modified to extend their application to SFRC. Thus obtained monotonic material models of concrete and reinforcing bars in SFRC members are combined with unloading/reloading loops used in the cyclic models of concrete and reinforcing bars in normal reinforced concrete. The resulting path-dependent cyclic material models are then incorporated in a finite-element based fiber analysis program. The applicability of these models at member level is verified by simulating cyclic lateral loading tests of SFRC columns under constant axial compression. The analysis using the proposed SFRC models yield results that are much closer to the experimental results than the analytical results obtained using the normal reinforced concrete models are.