• Title/Summary/Keyword: steady state tests

검색결과 238건 처리시간 0.026초

GHP 운전시 COV에 의한 정상상태 판별 및 이상검출 방법 연구 (A Study on Steady-State Criterion based on COV and a Fault Detection Method during GHP Operation)

  • 신영기;오세재;정진희
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.705-710
    • /
    • 2011
  • Fault detection has to be proceeded by steady state filtering to get rid of transient effect associated with thermal capacity. Coefficient of variance (COV), ratio of standard deviation devided by moving average, was employed as steady-state filter. Engine speed and refrigerant pressures were selected as parameters representing system dynamics. The filtered values were registered as members of steady-state DB. They were found to show good functional relationship with ambient temperature. The relationship was fitted with a second order polynomial and the distribution bounds of the data around the fitted curve were expressed by visual inspection because of varying average and random data interval. Fault data were compared with the steady-state data obtained during normal operation. The fault data were easily isolated from the fault-free one. To make such isolation reliable, tests to construct good DB should be designed in a systematic way.

Grade 91 강의 크리프 균열성장 거동에 대한 천이영역과 정상상태영역의 상관 관계 (Correlation Between Transient Regime and Steady-State Regime on Creep Crack Growth Behavior of Grade 91 Steel)

  • 박재영;김우곤;;김선진;김응선
    • 대한기계학회논문집A
    • /
    • 제39권12호
    • /
    • pp.1257-1263
    • /
    • 2015
  • 제 4 세대 원자로의 고온 구조재료로 사되는 Grade 91 강의 크리프 균열성장 거동에 대한 천이영역과 정상상태영역에서의 상관 관계를 조사하였다. 이를 위해 $600^{\circ}C$의 동일한 온도 및 동일한 하중조건에서 1/2" CT 시편을 사하여 크리프 균열성장 시험 데이터를 얻었다. 크리프 균열성장 속도식은 $C^*$-파괴매개변수를 사하여 천이영역과 정상상태영역에서의 평가 식을 각각 도출하였다. $C^*$와 da/dt 의 관계에서 천이영역의 크리프 균열성장 속도는 시험 데이터의 산포가 크지만 정상상태영역의 크리프 균열성장 속도와 비슷한 기울기로서 상관성이 있었으며 천이영역 균열성장속도는 정상상태 균열성장속도에 비해 약 5.6 배 낮았다. 본 결과를 이하면 짧은 시간의 천이영역 균열성장속도로부터 장시간의 시험으로 얻을 수 있는 정상상태 균열성장속도를 예측할 수 있다.

DETERMINATION OF TRANSIENT WEAR DISTANCE IN THE ADHESIVE WEAR OF A6061 ALUMINIUM ALLOY REINFORCED WITH ALUMINA PARTICLES

  • Yang, L.J.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.217-218
    • /
    • 2002
  • An integrated adhesive wear model was proposed to determine the transient wear and steady-state wear of aluminium alloy matrix composites. The transient wear volume was described by an exponential equation, while the steady-state wear was governed by a revised Archard equation, in which both the transient wear volume and transient sliding distance were excluded. A mathematical method was developed to determine both the transient distance and the net steady-state wear coefficient. Experimental wear tests were carried out on three types of commercial A6061 aluminum alloy matrix composites reinforced with 10%, 15% and 20% alumina particles. More accurate wear coefficient values were obtained with the proposed model. The average standard wear coefficient, as determined by the original Archard equation, was found to be about 51% higher.

  • PDF

결정질 암반에서 Moye 방법을 이용한 정압시험의 해석에 대한 고찰 (Study on Moye's Method for Analysis of Constant-Head Tests Conducted in Crystalline Rock)

  • 박경우;박병학;지성훈;이강근
    • 지질공학
    • /
    • 제33권4호
    • /
    • pp.519-530
    • /
    • 2023
  • 본 논문에서는 정류 상태의 정압시험에 대한 해석 방법 중 Moye 해석해를 고찰해 보았으며, 현장수리시험에서 정압시험에 대한 정류 상태의 해석과 부정류 상태의 해석에 대해 비교해 보았다. Moye 해석해로 산출한 수리전도도는 시험 구간의 크기가 작을수록 민감도가 커지기 때문에 시험 구간의 길이를 가능한 시험 조건에서 크게 설정하여 현장수리시험을 수행하는 것이 바람직하다. 특히 10-8 m/sec 이하의 수리전도도를 갖는 저투수성 매질에서는 부정류 상태의 해석 결과에 비해 Moye 해석해로 도출한 수리전도도의 값이 작게 도출되는데, 이는 Moye 식에서 가정한 방사성 흐름과 구상 흐름의 경계면을 조정할 경우 보완할 수 있었다. KURT내 연구용 시험공에서 수행한 정압시험 결과, 저투수성 매질에서 부정류 상태의 시험을 통해 도출한 투수성이 정류 상태의 결과에 비해 큰 값이 도출되었다. 이는 정압시험에 의해 형성되는 방사상 흐름에서 구상 흐름으로 바뀌는 지하수 흐름의 경계면이 Moye 식에서 가정한 '시험구간 길이의 절반'보다 작게 형성되었기 때문으로 판단되며, 결국 결정질 암반에서 수행한 정압시험을 해석할 때 단순히 정류 상태의 해석으로 매질의 수리지질특성을 판단하기보다는 정류 상태의 해석에서 수반되는 가정 조건을 고려하여 부정류 상태의 시험 결과와 함께 비교하여 해석한다면 매질의 수리지질특성을 보다 잘 이해할 수 있을 것으로 사료된다.

멀티형 히트펌프 시스템 컴퓨터 시뮬레이션과 실험적 검증 (Multi type heat pump system computer simulation and experimental verification)

  • 한도영;정민영
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.12-19
    • /
    • 2000
  • The multi type heat pump system may provide more energy savings and better environmental conditions than the single type heat pump system may do. In order to design a multi type heat pump system, it may be recommended to develop the system simulation program, which can predict the characteristics of the system such as unit capacities, power consumptions, and system COP's. In this study, the steady state simulation program of the multi type heat pump system was developed. The results from the simulation program were compared with those from the experimental tests which were performed in the environmental chamber, Cooling tests show 3.11% and 0.94% of error in capacity and COP, and heating tests show 3.30% and 1.90% of error in capacity and COP, respectively. Therefore, the steady state simulation program developed for this study can effectively be used for the design and the performance prediction of the multi type heat pump system.

  • PDF

침투력을 고려한 토사터널 막장의 안정성 평가방법에 대한 고찰 (Evaluation of Tunnel Face Stability with the Consideration of Seepage Forces)

  • 남석우;이인모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.193-200
    • /
    • 1999
  • Since Broms and Bennermark(1967) suggested the face stability criterion based on laboratory extrusion tests and field observations, the face stability of a tunnel driven in cohesive material has been studied by several authors. And recently, more general solution for the tunnel front is given by Leca and Panet(1988). They adopted a limit state design concept to evaluate the face stability of a shallow tunnel driven into cohesionless material and showed that the calculated upper bound solution represented the actual behavior reasonably well. In this study, two factors are simultaneously considered for assessing tunnel face stability: One is the effective stress acting on the tunnel front calculated by upper bound solution; and the other is the seepage force calculated by numerical analysis under the condition of steady state ground water flow. The model tests were performed to evaluate the seepage force acting on the tunnel front and these results were compared with results of numerical analysis. Consequently, the methodology to evaluate the stability of a tunnel face including limit analysis and seepage analysis is suggested under the condition of steady state ground water flow.

  • PDF

Determining the flow curves for an inverse ferrofluid

  • Ekwebelam, C.C.;See, H.
    • Korea-Australia Rheology Journal
    • /
    • 제20권1호
    • /
    • pp.35-42
    • /
    • 2008
  • An inverse ferrofluid composed of micron sized polymethylmethacrylate particles dispersed in ferrofluid was used to investigate the effects of test duration times on determining the flow curves of these materials under constant magnetic field. The results showed that flow curves determined using low duration times were most likely not measuring the steady state rheological response. However, at longer duration times, which are expected to correspond more to steady state behaviour, we noticed the occurrence of plateau and decreasing flow curves in the shear rate range of $0.004\;s^{-1}$ to ${\sim}20\;s^{-1}$, which suggest the presence of nonhomogeneities and shear localization in the material. This behaviour was also reflected in the steady state results from shear start up tests performed over the same range of shear rates. The results indicate that care is required when interpreting flow curves obtained for inverse ferrofluids.

Al-10wt% TiCp복합재료의 정적 크립특성 (Static Creep Characteristics of AI-10wt% TiCp Composites)

  • 임종국;박종건
    • 열처리공학회지
    • /
    • 제6권3호
    • /
    • pp.159-165
    • /
    • 1993
  • Creep tests of the TiC particulate reinforced Al composite have been conducted in the temperature ranges from 200 to $500^{\circ}C$. The steady-state cree rate of the composite depended strongly on the temperature and ap' plied stress. The stress exponent for the steady state creep rate of the composites was approximately 17.5 and the activation anergy was calculated to be 390KJ/mol. The steady-state creep equation could be written as $\acute{\varepsilon}_{ss}$ $$(s^{-1})=1.5{\times}10^{-9}\;{\sigma}^{17.5}\exp(-390000/RT)$$. Fracture surface examination showed that the fracture mode of the particulate reinforced composite was ductile by plastic tearing of the aluminum matrix and TiC particle interfaces were offered as sites for crack.

  • PDF

AZ31합금의 크립특성에 미치는 Sb의 영향 (Effect of Sb on the Creep Behavior of AZ31 Alloy)

  • 손근용;티안수구이;김경현
    • 연구논문집
    • /
    • 통권33호
    • /
    • pp.137-145
    • /
    • 2003
  • The effects of antimony addition on the microstructures and creep behavior of AZ31 magnesium alloy have been investigated. Constant load creep tests were carried out at temperatures ranging from $150^{\circ}C$ to $200^{\circ}C$, and an initial stress of 50MPa for AZ31 alloys containing antimony up to 0.84% by weight. Results show that small additions of antimony to AZ31 effectively decreased the creep extension and steady state creep rates. The steady state creep rate of AZ31 was reduced 2.5 times by the addition of 0.84% of antimony. The steady state creep rate of AZ31-0.84Sb alloy was controlled by dislocation climb in which the activation energy for creep was 128 kJ/mole. The microstructure of as-cast AZ31-0.84%Sb alloy showed the presence of $Mg_3Sb_2$ precipitates dispersed throughout the matrix. The main reason for the higher creep resistance in AZ31-Sb alloys is due to the presence $Mg_3Sb_2$, which effectively hindered the movement of dislocations during the elevated temperature creep.

  • PDF

Development and validation of a fast sub-channel code for LWR multi-physics analyses

  • Chaudri, Khurrum Saleem;Kim, Jaeha;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1218-1230
    • /
    • 2019
  • A sub-channel solver, named ${\underline{S}}teady$ and ${\underline{T}}ransient$ ${\underline{A}}nalyzer$ for ${\underline{R}}eactor$ ${\underline{T}}hermal$ hydraulics (START), has been developed using the homogenous model for two-phase conditions of light water reactors. The code is developed as a fast and accurate TH-solver for coupled and multi-physics calculations. START has been validated against the NUPEC PWR Sub-channel and Bundle Test (PSBT) database. Tests like single-channel quality and void-fraction for steady state, outlet fluid temperature for steady state, rod-bundle quality and void-fraction for both steady state and transient conditions have been analyzed and compared with experimental values. Results reveal a good accuracy of solution for both steady state and transient scenarios. Axially different values for turbulent mixing coefficient are used based on different grid-spacer types. This provides better results as compared to using a single value of turbulent mixing coefficient. Code-to-code evaluation of PSBT results by the START code compares well with other industrial codes. The START code has been parallelized with the OpenMP algorithm and its numerical performance is evaluated with a large whole PWR core. Scaling study of START shows a good parallel performance.