• Title/Summary/Keyword: steady state

Search Result 5,367, Processing Time 0.03 seconds

Quality of Coverage Analysis on Distributed Stochastic Steady-State Simulations (분산 시뮬레이션에서의 Coverage 분석에 관한 연구)

  • Lee, Jong-Suk-R.;Park, Hyoung-Woo;Jeong, Hae-Duck-J.
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.519-524
    • /
    • 2002
  • In this paper we study the qualify of sequential coverage analysis under a scenario of distributed stochastic simulation known as MRIP(Multiple Replications In Parallel) in terms of the confidence intervals of coverage and the speedup. The estimator based in the F-distribution was applied to the sequential coverage analysis of steady-state means. in simulations of the $M/M/1/{\infty},\;M/D/I/{\infty}\;and\;M/H_{2}/1/{\infty}$ queueing systems on a single processor and multiple processors. By using multiple processors under the MRIP scenario, the time for collecting many replications needed in sequential coverage analysis is reduced. One can also easily collect more replications by executing it in distributed computers or clusters linked by a local area network.

Analysis on the Filling Mode of Propellant Supply System for the Korea Space Launch Vehicle (한국형발사체 추진제공급시스템 충전모드 해석)

  • Lee, Jaejun;Park, Sangmin;Kang, Sunil;Oh, Hwayoung;Jung, Eun Sang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.50-58
    • /
    • 2016
  • Korean Space Launch Vehicle (KSLV-II) Propellant Supply System charges liquid oxygen and kerosene to each propellant tank for the stages. To charge the launch vehicle propellant tank safety, the propellant charge flow rates and scenarios should be defined. First, the Propellant Supply System was modeled with 1D flow analysis program. The control valve capacity and orifice size were calculated by performing the 1D steady state simulation. Second, the 1D transient simulation was performed by using the steady state simulation results. As propellants were being charged at the each tank, the increased tank liquid level decreases the charge flow rate. Consequently, the proposed supply system satisfies the required design charging conditions.

A Performance Evaluation of FC-MMA Adaptive Equalization Algorithm by Step Size (스텝 크기에 의한 FC-MMA 적응 등화 알고리즘의 성능 평가)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.27-32
    • /
    • 2021
  • This paper evaluates the equalization performance of FC-MMA adaptive equalization algorithm by the fixed step size that is used for the minimization of the intersymbol interference which occurs in the time dispersive communication channel. The FC-MMA has a fast convergence speed in order to adapts the new environment more rapidly in case of the time varying charateristics and the abnormal situation like as outage of the communication channel. But the algorithms operates in adative method, convegence speed is depend on fixed step size for adaptation. For this situation, its performance was evaluated by changing the step size value, the residual isi and maximum distortion and MSE performance index which means the convergence characteristics are widely adapted in the adaptive equalizer, SER were applied. As a result of computer simulation, the large step size can improves the convergence speed for reaching the steady state, but has a poor performance compared to small step size in residual values after steady state. The research result shows that the FC-MMA algorithm is applied the large step size for rapidly reaching the steady state in initial time, then adjust the small step size after reaching the steady state for reducing the residual values for equalization.

A Study on Steady State Characteristics of LLC Resonant Half Bridge Converter Considering Internal Losses (내부 손실이 고려된 LLC 공진형 하프브릿지 컨버터의 정상상태 특성에 관한 연구)

  • Ahn, Tae-Young
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.985-991
    • /
    • 2018
  • In this paper, an equivalent circuit reflecting the internal loss of the LLC resonant half bridge converter was proposed and a steady state characteristic equation including the loss factors was derived. Using the results, the frequency characteristics of I/O voltage gain and input impedance were compared with the lossless model In order to verify the proposed model and the derived equation, the main components of the 1kW class LLC resonant half bridge converter were selected under the same conditions and the steady state characteristics such as voltage gain and input impedance were compared. In particular, to compare more closely the steady state error of the two models, we observed the change in switching frequency with respect to the load current, which is considered to be the most important in the actual circuit design stage. As a result, it is confirmed that the error of the operating frequency is significantly improved from the proposed model and the analysis result.

A Study on the Optimal Design of LLC Resonant Half-bridge dc-dc Converter Using a Steady-state Model with Internal Loss Resistors (내부 손실 저항이 있는 정상상태 모델을 이용한 LLC 공진형 하프 브리지 dc-dc컨버터의 최적 설계에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.80-86
    • /
    • 2022
  • In this paper, the optimal design and circuit simulation verification results of an LLC resonant half-bridge dc-dc converter using a steady-state model with internal loss resistance are reported. Above all, the input/output voltage gain and frequency characteristic equations in the steady-state were derived by reflecting the internal loss resistance in the equivalent circuit. Based on the results, an LLC resonant half-bridge dc-dc converter with an input voltage of 360-420V, an output voltage of 54V, and a maximum power of 3kW was designed, and to verify the design, the PSIM circuit simulation was executed to compare and analyze the result. In particular, the operating range of the converter could be drawn from the frequency characteristic graph of the voltage gain, and when the converter was operated under light and maximum load conditions, it was confirmed that similar results were obtained by comparing simulation results and calculation results in the switching frequency characteristic graph. In addition, the change of the switching frequency with respect to the load current at each input voltage was compared with the calculated value and the simulation result. As a result, it was possible to confirm the usefulness of the analysis result reflecting the internal loss resistance proposed in this paper and the process of the optimal design.

HYBRID ON-OFF CONTROLS FOR AN HIV MODEL BASED ON A LINEAR CONTROL PROBLEM

  • Jang, Tae Soo;Kim, Jungeun;Kwon, Hee-Dae;Lee, Jeehyun
    • Journal of the Korean Mathematical Society
    • /
    • v.52 no.3
    • /
    • pp.469-487
    • /
    • 2015
  • We consider a model of HIV infection with various compartments, including target cells, infected cells, viral loads and immune effector cells, to describe HIV type 1 infection. We show that the proposed model has one uninfected steady state and several infected steady states and investigate their local stability by using a Jacobian matrix method. We obtain equations for adjoint variables and characterize an optimal control by applying Pontryagin's Maximum Principle in a linear control problem. In addition, we apply techniques and ideas from linear optimal control theory in conjunction with a direct search approach to derive on-off HIV therapy strategies. The results of numerical simulations indicate that hybrid on-off therapy protocols can move the model system to a "healthy" steady state in which the immune response is dominant in controlling HIV after the discontinuation of the therapy.

A Study of the Transient Flow Characteristics of a Vacuum Ejector-Diffuser System.

  • Rajesh, G.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2769-2774
    • /
    • 2007
  • In vacuum ejector-diffuser systems where a finite volume secondary chamber is used, the secondary jet exhibits transient characteristics during start-up. A steady state is achieved after some time in which mass entrainment prevails indefinitely inside the ejector, though there is no flow from the secondary chamber. An attempt is made in this work to study the infinite entrainment of secondary jet into the primary jet from a finite secondary chamber, with the help of a computational fluid dynamics method. The present study is also intended to identify the operating range of vacuum ejector-diffuser systems where the steady flow assumption can be applied without uncertainty. The results obtained show that the only condition in which an infinite mass entrainment is possible is the generation of a re-circulation zone near the primary nozzle exit. The flow in the secondary chamber attains a state of dynamic equilibrium at this point. Steady flow assumption is valid only after this point.

  • PDF

Analysis of steady-states and dynamic characteristics of a continuous MMA/MA copolymerization reactor (연속식 MMA/MA 공중합 반응기의 정상상태 및 동특성 해석)

  • 박명준;안성모;이현구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.309-312
    • /
    • 1997
  • The dynamic characteristics of a continuous MMA/MA free-radical solution copolymerization reactor were studied. A mathematical model was developed and kinetic parameters which had been estimated in the previous work were used. With this model, bifurcation diagrams were constructed with various parameters as the bifurcation parameter to predict the region of stable operating conditions and to enhance the controller performance. It was shown that the steady-state multiplicity existed over wide ranges of residence time and jacket inlet temperature. Periodic solution branches were found to emanated from Hopf bifurcation points. Under certain conditions isola was also observed, which would result in poor performance of feedback controllers.

  • PDF

Thermal Analysis of Vehicle Radiator (차량용 라디에이터의 열 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • This study analyzes the thermal stress at automotive radiators on steady and transient states. The maximum displacement is shown at the lower corner of upper tank with the value of 0.51mm. The displacement becomes smaller at the center of radiator and it becomes larger at this edge. The maximum thermal stress with the value of 62 MPa is shown at the contact between upper tank and cooling plate. Thermal maximum stress with the transient state at the elapsed time of 10 second is lower than that at steady state as much as 0.7%.

  • PDF

A STUDY OF PREDICTION METHOD FOR DYNAMIC STABILITY DERIVATIVE USING STEADY STATE SIMULATION IN NON-INERTIAL COORDINATE (비관성 좌표계에서의 정상해석을 통한 동 안전 미계수 예측 기법 연구)

  • Lee, H.R.;Lee, S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.428-433
    • /
    • 2011
  • In this paper, a prediction method for dynamic stability derivatives is studied using steady state simulations in rotational coordinates. The simulations require the extension of a standard CFD formulations based on inertial coordinate. A new CFD code based on the method are developed. Flows induced by steady circular motions of airfoils with a constant pitch rate are simulated with the code. From the numerical simulations, the pitch rate derivatives are obtained at various Mach numbers, and the results are compared with other numerical results. The numerical simulations show that the new code are capable of predicting dynamic stability derivatives.

  • PDF