• 제목/요약/키워드: stay-cable bridge

검색결과 93건 처리시간 0.02초

Experimental investigation on multi-mode vortex-induced vibration control of stay cable installed with pounding tuned mass dampers

  • Liu, Min;Yang, Wenhan;Chen, Wenli;Li, Hui
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.579-587
    • /
    • 2019
  • In this paper, pounding tuned mass dampers (PTMDs) were designed to mitigate the multi-mode vortex-induced vibration (VIV) of stay cable utilizing the viscous-elastic material's energy-dissipated ability. The PTMD device consists of a cantilever metal rod beam, a metal mass block and a specially designed damping element covered with viscous-elastic material layer. Wind-tunnel experiment on VIV of stay cable model was set up to validate the effectiveness of the PTMD on multi-mode VIV mitigation of stay cable. By analyzing and comparing testing results of all testing cases, it could be verified that the PTMD with viscous-elastic pounding boundary can obviously mitigate the VIV amplitude of the stay cable. Moreover, the installed location and the design parameters of the PTMD device based on the controlled modes of the primary stay cable, would have a certain extent suppression on the other modal vibration of the stay cable, which means that the designed PTMDs are effective among a large band of frequency for the multi-mode VIV control of the stay cable.

Vibration mitigation of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Sun, Limin;Jiang, Xiaolu
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.35-53
    • /
    • 2012
  • Mechanical dampers have been proved to be one of the most effective countermeasures for vibration mitigation of stay cables in various cable-stayed bridges over the world. However, for long stay cables, as the installation height of the damper is restricted due to the aesthetic concern, using passive dampers alone may not satisfy the control requirement of the stay cables. In this connection, semi-active MR dampers have been proposed for the vibration mitigation of long stay cables. Although various studies have been carried out on the implementation of MR dampers on stay cables, the optimal damping performance of the cable-MR damper system has yet to be evaluated. Therefore, this paper aims to investigate the effectiveness of MR damper as a semi-active control device for the vibration mitigation of stay cable. The mathematical model of the MR damper will first be established through a performance test. Then, an efficient semi-active control strategy will be derived, where the damping of MR damper will be tuned according to the dynamic characteristics of stay cable, in order to achieve optimal damping of cable-damper system. Simulation study will be carried out to verify the proposed semi-active control algorithm for suppressing the cable vibrations induced by different loading patterns using optimally tuned MR damper. Finally, the effectiveness of MR damper in mitigating multi modes of cable vibration will be examined theoretically.

Effects of tensioning forces on the structural behavior of cable-stayed bridges

  • Lam, Pauline Lin Li;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.457-464
    • /
    • 2022
  • Optimization in distribution of stay cable forces is one of the most difficult aspects in the design of cable-stayed bridges. This article attempts to examine tension force influence on structural behavior of cable-stayed bridges. For the examination, finite element modeling using nonlinear static and nonlinear modal analyses was completed and compared to structural experimental results. Variables analyzed in this parametric study were: 1) Number of stay cables; 2) Tension of the stay cables, and 3) Stay cable pattern - harp and semi-fan patterns. Though the findings from the analysis are limited to the tested models, the study gives insight on the structural behavior of actual cable stayed bridges.

Damage prevention and aerodynamics of cable-stayed bridges in heavy snowstorms: A case study

  • Mladen, Bulic;Mehmed, Causevic
    • Structural Engineering and Mechanics
    • /
    • 제85권1호
    • /
    • pp.81-88
    • /
    • 2023
  • This paper begins by analyzing cable vibrations due to external excitations and their effects on the overall dynamic behavior of cable-stayed bridges. It is concluded that if the natural frequency of a cable approaches any natural frequency of the bridge, the cable loses its rigidity and functionality. The results of this analysis explain the phenomenon that occurred on the Dubrovnik Bridge in Croatia during a storm and measures for its retrofit. A field test was conducted before the bridge was opened to traffic. It was concluded: "The Bridge excited unpleasant transverse superstructure vibration with the frequency of approximately 0.470 Hz. Hence, it seems possible that a pair of stays vibrating in phase may excite deck vibrations". Soon after this Bridge opened, a storm dumped heavy damp snow in the area, causing the six longest cable stay pairs of the main span to undergo large-amplitude vibrations, and the superstructure underwent considerable displacements in combined torsion-sway and bending modes. This necessitated rehabilitation measures for the Bridge including devices to suppress the large-amplitude vibrations of cables. The rehabilitation and monitoring of the Bridge are also presented here.

케이블의 비선형 가동효과를 고려한 사장교 강거더의 좌굴 안전성 평가 (Buckling Stability in the deck Steel Girder of Cable stayed Bridge Considered Nonlinear Behavior of Stay Cable)

  • 최학재
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.129-139
    • /
    • 2005
  • The focused topic according to be slender and longer of cable stayed bridge's main span is as follows (1) Aerodynamic stability (2) Lateral movement of stiffening girder caused by wind force during and after construction (3) Global bucking of stiffening girder caused by axial force Among this, the number 3 has not received much attention in the past due to high buckling safety factor of stiffening girder. However, according to be slender of stiffening girder, the topic of buckling stability of girder is not any more unconcerned subject. The purpose of this paper is to examine the effect of stay cable's nonlinear behavior on the buckling stability of cable-stayed bridge.

  • PDF

Full-scale experimental verification on the vibration control of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Liu, Jiangyun;Sun, Limin
    • Smart Structures and Systems
    • /
    • 제16권6호
    • /
    • pp.1003-1021
    • /
    • 2015
  • MR dampers have been proposed for the control of cable vibration of cable-stayed bridge in recent years due to their high performance and low energy consumption. However, the highly nonlinear feature of MR dampers makes them difficult to be designed with efficient semi-active control algorithms. Simulation study has previously been carried out on the cable-MR damper system using a semi-active control algorithm derived based on the universal design curve of dampers and a bilinear mechanical model of the MR damper. This paper aims to verify the effectiveness of the MR damper for mitigating cable vibration through a full-scale experimental test, using the same semi-active control strategy as in the simulation study. A long stay cable fabricated for a real bridge was set-up with the MR damper installed. The cable was excited under both free and forced vibrations. Different test scenarios were considered where the MR damper was tuned as passive damper with minimum or maximum input current, or the input current of the damper was changed according to the proposed semi-active control algorithm. The effectiveness of the MR damper for controlling the cable vibration was assessed through computing the damping ratio of the cable for free vibration and the root mean square value of acceleration of the cable for forced vibration.

사장교 케이블 동특성 평가를 위한 케이블 가진시스템 개발 (Development of Cable Excitation System for Evaluating Dynamic Characteristics of Stay Cables)

  • 김남식;정운;서주원;안상섭
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.71-79
    • /
    • 2003
  • 사장교에서 케이블은 교량 전체에 있어서 매우 중요한 요소이다. 차량, 바람 혹은 풍우에 의한 케이블의 진동은 교량의 안전성과 사용성을 감소시키는 주요 원인이 되어왔으며 이러한 문제를 해결하는 효과적인 방법중의 하나는 케이블 댐퍼를 설치하는 것이다. 이 케이블 댐퍼를 최적으로 설계하기 위해서는 케이블의 동특성을 정확하게 평가해야 하며 케이블 동특성치를 얻기 위해서는 정확한 가진이 필요하다. 따라서 본 연구에서는 케이블 가진시스템을 개발하고 성능을 평가하기 위해 케이블 가진시스템의 운동방정식을 유도하였으며, 케이블 가진기를 케이블 모형에 설치하여 정현진동실험과 공진진동실험을 수행하여 케이블의 동특성을 효과적으로 구하였다.

Numerical study on the mitigation of rain-wind induced vibrations of stay cables with dampers

  • Li, Shouying;Wu, Teng;Li, Shouke;Gu, Ming
    • Wind and Structures
    • /
    • 제23권6호
    • /
    • pp.615-639
    • /
    • 2016
  • Although the underlying mechanism of rain-wind induced vibrations (RWIVs) of stay cables has not been fully understood, some countermeasures have been successfully applied to mitigating this kind of vibration. Among these, installing dampers near the bridge deck was widely adopted, and several field observations have shown its effectiveness. In this study, the effectiveness of dampers to RWIVs of stay cables is numerically investigated comprehensively by means of finite difference method (FDM). Based on the free vibration analysis of a taut string, it is found that the 3-points triangle scheme, which can be easily implemented in FDM, can offer an excellent approximation of the concentrated damping coefficient (expressed as a Dirac delta function) at the location where the damper is installed. Then, free vibration analysis of a 3-D continuous stay cable attached with two dampers is carried out to study the relationship of modal damping ratio and damping coefficient of the dampers. The effects of orientation of the dampers and cable sag on the modal damping ratio are investigated in detail. Finally, the RWIV response of a 3-D continuous stay cable attached with two dampers is examined. The results indicate that 0.5% of damping ratio is sufficient to reduce the RWIV vibration of the Cable A20 on the No.2 Nanjing Bridge over Yangtze River.

진동법을 이용한 인장 케이블의 장력 추정에 관한 연구 (Evaluation of Tension Force of Stay Cables Using Vibration Method)

  • 김남식;정운
    • 한국소음진동공학회논문집
    • /
    • 제12권12호
    • /
    • pp.956-963
    • /
    • 2002
  • In a recent construction industry, cable supported structures such as a cable-stayed bridge or space stadium have been increasingly constructed according to rapidly upgrade their related technologies. Generally stay cables as a critical member need to be rearranged for being satisfied with design tension forces. In this purpose, a vibration method has been applied to estimate the tension forces exerted on existing stay cables. In this study, cable vibration tests were tarried out to evaluate the cable tension forces comparing with theoretical and practical formulas. Using the measured frequencies obtained from free vibration and Impulsive tests, an accuracy of the estimated tension forces is confirmed according to use the first single mode only or higher multiple modes.

Theoretical investigation on rain-wind induced vibration of a continuous stay cable with given rivulet motion

  • Li, Shouying;Chen, Zhengqing;Li, Shouke
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.481-503
    • /
    • 2014
  • A new theoretical model on rain-wind induced vibration (RWIV) of a continuous stay cable is developed in this paper. Different from the existing theoretical analyses in which the cable was modeled as a segmental rigid element, the proposed scheme focuses on the in-plane and out-of-plane responses of a continuous stay cable, which is identical with the prototype cable on cable-stayed bridge. In order to simplify the complexities, the motion law of the rivulet on the cable surface is assumed as a sinusoidal way according to some results obtained from wind tunnel tests. Quasi-steady theory is utilized to determine the aerodynamic forces on the cable. Equations of motion of the cable are derived in a Cartesian Coordinate System and solved by using finite difference method to obtain the in-plane and out-of-plane responses of the cable. The results show that limited cable amplitudes are achieved within a limited range of wind velocity, which is a unique characteristic of RWIV of stay cable. It appears that the in-plane cable amplitude is much larger than the out-of-plane cable amplitude. Rivulet frequency, rivulet distribution along cable axis, and mean wind velocity profile, all have significant effects on the RWIV responses of the prototype stay cable. The effects of damping ratio on RWIVs of stay cables are carefully investigated, which suggests that damping ratio of 1% is needed to well mitigate RWIVs of prototype stay cables.