• Title/Summary/Keyword: statistical shape analysis

Search Result 408, Processing Time 0.029 seconds

DEEP-South: Asteroid Light-Curve Survey Using KMTNet

  • Lee, Hee-Jae;Yang, Hongu;Kim, Dong-Heun;Kim, Myung-Jin;Moon, Hong-Kyu;Kim, Chun-Hwey;Choi, Young-Jun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.46.3-47
    • /
    • 2020
  • Variations in the brightness of asteroids are caused by their spins, irregular shapes and companions. Thus, in principle, the spin state and shape model of a single object or, a combined model of spins, shapes and mutual orbit of a multiple components can be constructed from the analysis of light curves obtained from the time-series photometry. Using ground- and space-based facilities, a number of time-series photometric observations of asteroids have been conducted to find the possible causes of their light variations. Nonetheless, only about 2% of the known asteroids have been confirmed for their rotation periods. Therefore, a follow-on systematic photometric survey of asteroids is essential. We started an asteroid light curve survey for this purpose using Korea Microlensing Telescope Network (KMTNet) during 199 nights between the second half of 2019 and the first half of 2020. We monitored within a 2° × 14° region of the sky per each night with 25 min cadences. In order to observe as many asteroids as possible with a single exposure, we mostly focus on the ecliptic plane. In our survey, 25,925 asteroids were observed and about 8,000 of them were confirmed for their rotation periods. In addition, using KMTNet's 24-hour continuous monitoring, we collected many composite light curves of slow rotating asteroids that were rarely obtained with previous observations. In this presentation, we will introduce the typical light curves of asteroids obtained from our survey and present a statistical analysis of spin states and shapes of the asteroids from this study.

  • PDF

Evaluation of Major Taper Equation Models for Developing a Stem Volume Table of Cryptomeria japonica in Jeju Island (제주도 삼나무 수간재적표 개발을 위한 주요 수간곡선식 비교)

  • Hyun-Soo, Kim;Su-Young, Jung;Kwang-Soo, Lee
    • Journal of Environmental Science International
    • /
    • v.31 no.11
    • /
    • pp.941-950
    • /
    • 2022
  • This study was conducted to provide data and stem information to establish a local volume table of Cryptomeria japonica in Jeju Island. Stem analysis was performed on 26 trees by selecting two average trees from each site of the 13 plots of C. japonica stands in 2021 and 2022. During the analysis stage, one outlier tree was rejected, and a total of 260 observations of the specific stem height of 25 trees were used. Of the seven major taper equation models applied for parameter estimation and statistical verification, the Muhairwe 1999 model was found to be the best fit and selected as the optimal model. Stem shape-related estimates were acquired through the selected model, and sectional measurements according to the Smalian formula applied at an interval of 10 cm from the height of the stem were used to develop a volume table. A paired t-test comparison between the C. japonica volume obtained from the present study and those selected from the current yield table by NIFoS(2020), revealed significant differences (p<0.05), highlighting the necessity of a local volume table for C. japonica in Jeju Island.

Evaluation of marginal and internal gap under model-free monolithic zirconia restoration fabricated by digital intraoral scanner (디지털 구강스캐너로 모형 없이 제작한 전부지르코니아 수복물의 변연 및 내면 적합도 평가)

  • Lee, Jong-Won;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.210-217
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the marginal and internal adaptation of monolithic zirconia restoration made without physical model by digital intraoral scanner. Materials and methods: A prospective clinical trial was performed on 11 restorations as a pilot study. The monolithic zirconia restorations were fabricated after digital intraoral impression taking by intraoral scanner (TRIOS, 3shape, Copenhagen, Denmark), computer-aided designing, and milling manufacturing process. Completed zirconia crowns were tried in the patients' mouth and a replica technique was used to acquire the crown-abutment replica. The absolute marginal discrepancy, marginal gap, and internal gap of axial, line angle, and occlusal part were measured after sectioning the replica in the mesiodistal and buccolingual direction. Statistical analysis was performed using Kruskal-Wallis and Mann-Whitney U test (${\alpha}=.05$). Results: From the adaptation analysis by replica, the statistically significant difference was not found between mesiodistal and buccolingual sections (P>.05), but there was significant difference among the measurement location (P<.01). The amount of absolute marginal discrepancy was larger than those of marginal gap and internal gap (P<.01). Conclusion: Within the limitations of this study, the adaptation accuracy of model-free monolithic zirconia restoration fabricated by intraoral scanner exhibited clinically acceptable result. However, the margin of zirconia crown showed tendency of overcontour and cautious clinical application and follow up is necessary.

A Study on Enhancing the Performance of Detecting Lip Feature Points for Facial Expression Recognition Based on AAM (AAM 기반 얼굴 표정 인식을 위한 입술 특징점 검출 성능 향상 연구)

  • Han, Eun-Jung;Kang, Byung-Jun;Park, Kang-Ryoung
    • The KIPS Transactions:PartB
    • /
    • v.16B no.4
    • /
    • pp.299-308
    • /
    • 2009
  • AAM(Active Appearance Model) is an algorithm to extract face feature points with statistical models of shape and texture information based on PCA(Principal Component Analysis). This method is widely used for face recognition, face modeling and expression recognition. However, the detection performance of AAM algorithm is sensitive to initial value and the AAM method has the problem that detection error is increased when an input image is quite different from training data. Especially, the algorithm shows high accuracy in case of closed lips but the detection error is increased in case of opened lips and deformed lips according to the facial expression of user. To solve these problems, we propose the improved AAM algorithm using lip feature points which is extracted based on a new lip detection algorithm. In this paper, we select a searching region based on the face feature points which are detected by AAM algorithm. And lip corner points are extracted by using Canny edge detection and histogram projection method in the selected searching region. Then, lip region is accurately detected by combining color and edge information of lip in the searching region which is adjusted based on the position of the detected lip corners. Based on that, the accuracy and processing speed of lip detection are improved. Experimental results showed that the RMS(Root Mean Square) error of the proposed method was reduced as much as 4.21 pixels compared to that only using AAM algorithm.

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

Anatomical Measurement of the Masseter Muscle and Surface Mapping of the Maximal Thickness Point Using Computed Tomography Analysis (전산화단층촬영 영상분석을 이용한 교근의 해부학적 계측 및 최대 두께점 피부 표지화)

  • Suh, Hyeun-Woo;Kim, Hyo-Seong;Ha, Ki-Young;Kim, Boo-Yeong;Pae, Nam-Seok;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • Purpose: Masseter muscle is an important muscle of mastication. Because it has a great influence on the shape of low facial contour, patients who have masseteric hypertrophy show square-shaped jaw appearance. As aesthetic procedures for the reduction of the masseter muscle volume, radiofrequency ablation or botulinum toxin injection is at the center of attention. Authors studied the anatomical measurement of the thickness and width of masseter muscle and the surface mapping of the maximal thickness point using computed tomography (CT) scan to identify the useful guide for the injection of botulinum toxin in masseteric hypertrophy patients. Methods: We analyzed 2 mm-thickness OMU (ostiomeatal unit) CT of 112 normal people (224 masseter muscles) taken from June 2009 to May 2010. First, we measured the thickness, width and depth of the masseter muscle from the skin surface and analysed each by side, sex and age, respectively. The distribution of the thickness of the muscle and the correlation of thickness and width of the muscle were studied also. Second, we underwent surface mapping of the maximal thickness point using CT analysis by means of checking the vertical and horizontal distance from the angle of the mandible. Results: The average thickness and width of the masseter muscle was 17.73 mm and 40.78 mm in the male patients and were 14.33 mm and 37.42 mm in the female patients. Statistically, both figures of the male patients were larger than those of the female patients. However, the depth of the muscle from the skin surface in female patients (7.37 mm) was larger than that of the male patients (6.15 mm). There were no statistical difference in side or age. The width and thickness of the masseter muscle were in the positive correlation. The location of maximal thickness point of the masseter muscle was 27.77 mm vertically and 27.68 mm horizontally in the male patients, and 25.19 mm vertically and 25.42 mm horizontally in the female patients from the angle of mandible. Conclusion: We were able to present statistical evidence of the diagnosis and treatment of the masseteric hypertrophy regarding the anatomical measurements such as the thickness and width. And the maximal thickness point of the masseter muscle may be a useful guide for the clinical procedures of botulinum toxin injection.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

Growth Responses of Dieffenbachia amoena 'Marianne' and Begonia rex to Different Lengths and Numbers of Slitwalls in Drainless Containers for Green Technology (녹색기술 무배수구 용기깊이와 슬릿(Slit)차이에 따른 디펜바키아 마리안느와 렉스 베고니아의 생육반응)

  • Ju, Jin-Hee;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.931-938
    • /
    • 2012
  • The effects were investigated of different lengths and numbers of slitwalls in drainless containers on growth and change in soil moisture volumes on the growth of Diffenbachia amoena 'Marianne' and Begonia rex. Drainless containers filled with amended soil, with square shape ($240mm{\times}240mm$) were used, as well as three different sets of slitwalls (2, 4 or 8, respectively) in addition to non-slitwall containers. Two indoor foliage plants were grown in slitwall containers in randomized blocks with 3 replications in greenhouse conditions, from March to September, 2009. Soil moisture volumes per container were measured by weighing containers every 2 hours during the day. The change in soil moisture volumes showed considerable differences among slitwalls tested in comparison to control containers before and after twice-weekly irrigation. Particularly, the differences in the S2 (195mm, slitwall 2) containers were significantly greater than other containers tested. For Diffenbachia amoena 'Marianne', plant height, length of leaf, dry weight and fresh weight were higher with S2 containers than with those grown in other containers tested. The Begonia rex with the best quality in terms of plant height, length of leaf and width of leaf was grown in S8 (360mm, slitwall 8) containers. Particularly, statistical analysis has indicated that shoot fresh weights of Begonia rex grown in S8 were 3-fold higher than those grown in CS8 containers. The different results obtained within the two species led us to hypothesize a species-specific influence on indoor foliage plant performance. However, plants of both species grown in slitwall containers showed good results compared with plants grown in non-slitwall containers.

Comparisons of Dietary Habits and Eating Disorder by Obesity Index on One of Middle School Girls in Incheon (인천지역 일부 여중생의 비만도에 따른 섭식장애경향과 식습관의 비교)

  • Lee, Hyo-Jung;Rhie, Seung-Gyo;Won, Hyang-Rye
    • The Korean Journal of Community Living Science
    • /
    • v.19 no.1
    • /
    • pp.157-169
    • /
    • 2008
  • On the general trends of weight control for slimness, this study surveyed and compared eating attitude influenced by eating disorder, eating habits, and nutrition knowledge by obesity index in middle school girls. The purpose of this study was to investigate the eating disorders and eating habits, and analyzed these data by degree of obesity. This will provide basic information of nutrition education for adolescents who need to have proper body shape and dieting habits. This survey was conducted to one of girls' middle school in Incheon and all the data was analysed by SAS(Statistical Analysis System) program. The average height, weight and PIBW were 158.7cm, 48.2kg, and 93.9% in students. However, 50.8% of students were underweight or severely underweight. Most of female students perceived that they were normal or overweight even though they had underweight or normal. There was a significant difference in experience and intention of weight control by degree of obesity. In the overweight group, EAT-26 score tendency was high, especially preoccupation with losing weight(factor 1). It shows that obesity index had meaningful correlation with EAT-26 score and factor1. In dietary habit, overweight group showed more irregular meals tendency, and overeat frequently. On the other hand, this group had lower frequency and of smaller amount snacks. The intake frequency of meals and snacks showed in the affirmative way regardless of degree of obesity. The average score for nutrition knowledge about calorie and weight control was low. Correct answer rates were increased in higher overweight group. In conclusion, teenage girls who concerned too much about their slim body image need to be educated about accuracy concept of the body image. Also, practical and systematic nutrition education should be done for the correct nutrition knowledge and its application ability of individuals.

  • PDF

A Study of the Visual Image by Pattern Making of Jeans (청바지 패턴 제작에 따른 시각적 이미지 연구)

  • Kim, Kyeong-Hee;So, Yeon-Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.10
    • /
    • pp.1541-1551
    • /
    • 2009
  • This study gives guidelines to pattern designing by supplying various images of the transformed shape of jeans with the location of the waistline and the pants silhouette. For this study, 9 kinds of sample cloths (100% cotton denim) were designed considering the laying measurement of the jeans with the location of the waistline and the pants silhouette. The images of each sample were evaluated after the measurement of the completed samples. Clothing and textiles specialists used a semantic differential scale as the evaluation method of the images. For the statistical analysis of the data, one way Anova and Duncan test were adopted using the SPSS 12.0 program. The results of this study are as follows: 1. The visual image by the location of waistline and the change of the pants silhouette is composed of 3 factors (attraction, fashion and comfort factors) of which the attraction factor is the most important factor. 2. The visual image is positive when the location of the waistline is in the low waist position. It is attractive, fashionable, and comfortable. The visual image is negative when the location of the waistline is in the position of the natural waist. 3. The visual image is attractive when the pants silhouette is a boot-cut and fashionable when the pants silhouette are skinny. The straight-cut is comfortable but the visual image is negative. 4. There is no correlation between visual image by the location of the waistline and the change of the pants silhouette.