• 제목/요약/키워드: static test

검색결과 3,265건 처리시간 0.035초

공압서보밸브 KS규격 정립에 관한 연구 (A Study of Korean (Industrial) Standards for Pneumatic Servo Valve)

  • 김동수;이원희;최병오
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1231-1234
    • /
    • 2003
  • Pneumatic servo valve which is widely applied in industrial world is advanced technology compounded with electric, electronic and machine. And It is consist of Linear Force Motor. Spool Commutation Mechanism and Microprocessor. In this study, we accomplished test method of Linear Force motor test, Static characteristic test, Dynamic characteristic test for KS(Koran industrial standard) of Pneumatic servo valve. we accomplished study about the main item of Static characteristic test which is related to unload flow characteristic test. And Dynamic characteristic test was step input test and frequency response test. Specially about frequency response test, There was a difficulty resulting from the time delay problem caused by the basic compressibility of air. In order to solve the problem in this study. we proposed two methods. First, displacement of the servo valve spool was directly measured by using a laser sensor. Second, method of calculating control flow by measuring pressure and temperature of chamber.

  • PDF

무기체계 소프트웨어 신뢰성 시험 개선점 도출을 위한 소프트웨어 정적/동적 검증 분석 사례연구 (Analytical Study on Software Static/Dynamic Verification Methods for Deriving Enhancement of the Software Reliability Test of Weapon System)

  • 박지현;최병주
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제8권7호
    • /
    • pp.265-274
    • /
    • 2019
  • 무기체계 소프트웨어 개발 시 수행하는 신뢰성 시험은 크게 정적 검증과 동적 검증으로 구분된다. 정적 검증에서는 소프트웨어 코드를 수행시키지 않고 코딩 규칙 점검, 취약점 점검, 소스 코드 메트릭 점검을 수행하고, 동적 검증에서는 요구 사항을 기반으로 실제 소프트웨어를 실행시켜 기능을 검증하고 코드 실행률을 측정한다. 이러한 정적/동적 검증의 목적은 소프트웨어에 존재하는 결함을 발견하기 위한 것이다. 그러나 현재의 무기체계 소프트웨어 신뢰성 시험만으로는 여전히 탐지할 수 없는 결함들이 존재한다. 본 논문에서는 소프트웨어에서 발생할 수 있는 결함에 대해 무기체계 신뢰성 시험의 정적 검증과 동적 검증으로 탐지를 할 수 있는지를 사례실험을 통하여 분석 한다. 그 결과로 현재의 정적 검증과 동적 코드 커버리지 측정에서 더 나아가 무기체계 신뢰성 시험, 특히 동적 시험의 개선방안으로 연결하고자 한다.

PHC 매입말뚝의 동재하시험과 정재하시험의 지지력 비교·분석 연구 (A Comparative Study on the Bearing Capacity of Dynamic Load Test and Static Load Test of PHC Bored Pile)

  • 박종배
    • 한국지반환경공학회 논문집
    • /
    • 제18권9호
    • /
    • pp.19-31
    • /
    • 2017
  • 미국 사례의 경우 항타말뚝과 현장타설말뚝은 동재하시험과 정재하시험 지지력 상관관계 분석에서 좋은 상관관계를 나타내었다. 하지만, 국내에서는 해외에서 많이 사용하지 않는 매입말뚝으로 주로 시공을 하고 있으며, 매입말뚝의 동재하시험 신뢰성에 대해 의문이 많아 동재하시험의 신뢰도를 확인하고자 하였다. 본 연구에서는 LH 현장(천안, 인천, 의정부)에서 PHC 매입말뚝에 대하여 재하시험을 실시하였으며, 동재하시험(EOID 7회, Restrike 7회)과 정재하시험(7회) 지지력을 비교 분석하였다. 그 결과 재항타동재하지지력 및 정재하지지력 평균 값 비교 시 정재하지지력 평균 값이 약 27% 높게 나타났다(신뢰도 : 0.73, 변동계수 : 0.3). 재항타지지력(Davisson 판정 값) 및 정재하지지력(Davisson 판정 값) 평균 값 비교 시 정재하지지력(Davisson 판정 값) 평균 값이 약 27% 높게 나타났다(신뢰도 : 0.73, 변동계수 : 0.2). 동재하시험과 정재하시험의 차이를 줄이고자 본 연구에서는 수정동재하지지력(EOID의 극한선단지지력+Restrike의 극한주면마찰력)을 제시하였으며, 수정동재하지지력과 정재하지지력을 비교했을 때는 그 차이가 9%로 줄어들었다(신뢰도 : 0.91, 변동계수 : 0.2). 또한 변동계수가 0.2로 줄어들어 일관성이 증가한 것으로 나타났다.

적층 방법에 따른 복합재의 저온 영역 하에서 정적 강도 변화 (Effect of Fabrication Methods on Static Strength of Polymer Based Composites under the Low Temperature Range)

  • 엄수현;;권순철;김국진;김윤해
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.7-12
    • /
    • 2003
  • When the wind turbine is used in cold regions, the mechanical properties and dimension stability of the blade will be changed. The proposal of this paper is to test the durability of the blade for wind turbine. It is necessary to select the most comfortable materials and fabrication processes for more stable wind turbine blade in cold regions. To select the most comfortable materials and processes, the static strength has to know through the tensile static tests at the severe condition as cold regions. First, the tensile static specimens made by RIM (Resin injection molding) process & vacuum bagging process with reinforcement materials and resin. Tensile static tests were carried out on three laminate lay-ups (carbon prepreg, carbon fiber dry fabric and glass fiber dry fabric) at different test temperature($24^{\circ}$, $-30^{\circ}$), determining properties such as the mechanical strength, stiffness and strain to failure. At different test temperature, in order to test the tensile strengths of these specimens used the low temperature chamber. Next, the results of this test were compared with each other. Finally, the most comfortable materials and fabrication processes can select based on these results. The results show the changes in the static behavior of three laminate lay-ups at different test temperatures. At low temperatures, the static strengths are higher than the ones at room temperature.

  • PDF

적층 방법에 따른 고분자 기지 복합재의 저온 영역 하에서 정적 강도 변화의 비교 (A Comparison of the Effect of Fabrication Methods on Static Strength of Polymer Based Composites under the Low Temperature Range)

  • 엄수현;김윤해;최병근;;권순철;김국진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.196-201
    • /
    • 2003
  • When the structures are used in cold regions, the mechanical properties and dimension stability of the blade will be changed. The proposal of this study is to test the durability of the structures in cold regions. It is necessary to select the most comfortable materials and fabrication processes for more stable structures in cold regions. To select the most comfortable materials and processes, the static strength has to know through the tensile static tests at the severe condition as cold regions. First, the tensile static specimens made by RIM (Resin injection molding) process & vacuum bagging process with reinforcement materials and resin. Tensile static tests were carried out on three laminate lay-ups (carbon prepreg, carbon fiber dry fabric) at different test temperature($24^{\circ}C$, $-30^{\circ}C$), determining properties such as the mechanical strength, stiffness and strain to failure. At different test temperature, in order to test the tensile strengths of these specimens used the low temperature chamber. Next, the results of this test were compared with each other. Finally, the most comfortable materials and fabrication processes can select based on these results. The results show the changes in the static behavior of three laminate lay-ups at different test temperatures. At low temperatures, the static strengths are higher than the ones at room temperature.

  • PDF

가상현실기반과 고전적 스쿼트 운동 방법에 따른 정적, 동적 균형지수 간 상관분석 (The Correlation between Static and Dynamic Balance Index according to the Virtual Reality-Based Squat and Conventional Squat Exercise)

  • 윤정규
    • 대한통합의학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Purpose : The purpose of this study was to examine the correlation between static and dynamic balance according to the virtual reality-based squat and conventional squat exercise. Methods : Twenty four participants were randomly assigned to the virtual reality-based squat (VRS) group (n=12) or conventional squat (CS) group (n=12). The static balance (C90 area, C90 angle, trace length, sway average velocity) and dynamic balance (forward, rearward, leftward, rightward) were measured using a force plate by BT4. The VRS group used the virtual reality system during 4 weeks, while the CS group underwent classical squat training. Independent t-test was used to test the homogeneity of the general characteristics of the subjects. The collected data was analyzed using the paired t-test for static and dynamic balance comparisons before and after exercise in both groups and Pearson's test for the correlation between static and dynamic balance according to the measured time. The significance level was set to 0.05. Results : There was no significant correlation between group and static and dynamic balance related variables (p>.05). There was a significant correlation between measurement time and static and dynamic balance related variables (p<.05). According to the measurement time, the static balance parameter C90 area in the VRS group after exercise was significantly decreased (p<.05). The values of forward, leftward and rightward in the VRS group were significantly increased after exercise (p<.05). Conclusion : It is suggested that 20 normal healthy adult men and women who have normal balance ability can improve their ability to control their posture by improving the balance ability when applying virtual reality-based squat exercise.

모형토조실험을 통한 말뚝지지력의 평가 (Evaluation of Pile Bearing Capacity using Calibration Chamber Test)

  • 이인모;이명환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1992년도 봄 학술발표회 논문집 깊은 기초의 연구와 실무(RESEARCH AND PRACTICE OF DEEP FOUNDATIONS)
    • /
    • pp.13-40
    • /
    • 1992
  • Static formulae based on limiting equilibrium theories often provide misleading predictions of pile bearing capacity in cohesionless soils due to the incorrect basic assumptions or oversimplification of actual soil conditions. Soil conditions prior to pile driving are significantly changed after pile installation and imposition of high stress levels. Therefore soi1 parameters at failure rather than those obtained at initial conditions should be used in application of static formulae. In this research. model pile test data were analyzed and compared with the predicted values obtained from the various static formulae. The results showed that the proper choice of soil parameters remarkably improve the reliability of static formulae.

  • PDF

우주발사체용 복합재 산화제탱크 구조 강건성 검증을 위한 정하중 시험 (Static Load Test for Verification of Structural Robustness of Composite Oxidant Tank for Space Launch Vehicle)

  • 김현기;김성찬
    • 항공우주시스템공학회지
    • /
    • 제15권5호
    • /
    • pp.98-105
    • /
    • 2021
  • 본 연구에서는 우주발사체용 복합재 산화제탱크의 구조 강건성을 검증하기 위해 수행된 정하중시험 결과를 제시하였다. 먼저, 복합재 산화제탱크 정하중시험에 사용된 시험장비를 소개하고, 복합재 산화제탱크가 만족해야 하는 시험 요구도를 설명하였다. 그리고, 정하중 시험치구, 유압, 제어장비, 데이터획득장비로 구성되는 시험셋업 구성도를 제시하였고, 전단, 등가압축, 굽힘, 조합시험으로 구성된 복합재 산화제탱크 정하중 시험의 하중 프로파일을 제시하였다. 하중 제어의 결과로 시험하중 증가에 따른 각 하중부과기에서 입력하중과 출력하중 사이의 오차와 각 로드셀 A와 b 채널사이의 오차를 제시하여 본 시험의 신뢰성을 확인하였다. 정하중 시험 결과로, 각 시험에서 하중부과기의 하중은 허용 오차 범위 내에서 적절히 잘 제어되었으며, 시험시편도 요구 하중 내에서 파손이나 심각한 구조적 결함을 유발하는 좌굴은 발생하지 않는 것으로 확인되었다.

냉각 유량이 가스 포일 스러스트 베어링의 성능에 미치는 영향 (Effects of Cooling Flow Rate on Gas Foil Thrust Bearing Performance)

  • 황성호;김대연;김태호
    • Tribology and Lubricants
    • /
    • 제39권2호
    • /
    • pp.76-80
    • /
    • 2023
  • This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.

외부긴장 CFRP판용 정착부의 반복하중 실험 (Cyclic Loading Test of Anchorage System for Externally Prestressed CFRP Plate)

  • 정우태;박종섭;박영환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.262-265
    • /
    • 2006
  • This paper presents results on static and cyclic loading tests of anchorage system for externally prestressed CFRP plate. A total of 6 specimens have been tested. The specimens can be classified into the concrete surface specimens and the concrete near surface mounted specimens. Static test results before and after cyclic loading test reveal that anchorage system for externally prestressed CFRP plate has static capacity more than CFRP tensile strength.

  • PDF