• Title/Summary/Keyword: static parameters

Search Result 1,183, Processing Time 0.031 seconds

The Prediction of Injection Distances for the Minimization of the Pressure Drop by Empirical Static Model in a Pulse Air Jet Bag Filter (충격기류식 여과집진기에서 경험모델을 이용한 최소압력손실의 분사거리 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Lim, Woo-Taik
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.25-34
    • /
    • 2011
  • The new empirical static model was constructed on the basis of dimension analysis to predict the pressure drop according to the operating conditions. The empirical static model consists of the initial pressure drop term (${\Delta}P_{initial}$) and the dust mass number term($N_{dust}=\frac{{\omega}_0{\nu}_f}{P_{pulse}t}$), and two parameters (dust deposit resistance and exponent of dust mass number) have been estimated from experimental data. The optimum injection distance was identified in the 64 experimental data at the fixed filtration velocity and pulse pressure. The dust deposit resistance ($K_d$), one of the empirical static model parameters got the minimum value at d=0.11m, at which the total pressure drop was minimized. The exponent of dust mass number was interpreted as the elasticity of pressure drop to the dust mass number. The elasticity of the unimodal behavior had also a maximum value at d=0.11m, at which the pressure drop increased most rapidly with the dust mass number. Additionally, the correlation coefficient for the new empirical static model was 0.914.

Determination of DEM Input Parameters for Dynamic Behavior Simulation of Aggregates (골재의 동적 거동 모사를 위한 DEM 입력변수의 결정 연구)

  • Yun, Tae Young;Yoo, Pyeong Jun;Kim, Yeon Bok
    • International Journal of Highway Engineering
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2014
  • PURPOSES : Evaluation of input parameters determination procedure for dynamic analysis of aggregates in DEM. METHODS : In this research, the aggregate slump test and angularity test were performed as fundamental laboratory tests to determine input parameters of spherical particles in DEM. The heights spreads, weights of the simple tests were measured and used to calibrate rolling and static friction coefficients of particles. RESULTS : The DEM simulations with calibrated parameters showed good agreement with the laboratory test results for given dynamic condition. CONCLUSIONS : It is concluded that the employed calibration method can be applicable to determine rolling friction coefficient of DEM simulation for given dynamic conditions. However, further research is necessary to connect the result to the behavior of aggregate in packing and mixing process and to refine static friction coefficient.

Characteristics of Static Balance in Patients With Adolescent Idiopathic Scoliosis

  • Shin, Seung-Sub;Woo, Young-Keun
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.47-55
    • /
    • 2006
  • The purpose of this study was to compare the static balance of standing position between adolescent idiopathic scoliosis (AIS) and a normal group that were aged-matched. There were forty subjects included in this study. Twenty-seven healthy subjects (age, $13.9{\pm}1.2$ yrs; height, $161.9{\pm}7.5$ cm; weight, $52.2{\pm}7.7$ kg) and thirteen AIS subjects (age, $14.2{\pm}2.2$ yrs; height, $161.5{\pm}8.7$ cm; weight, $48.1{\pm}8.1$ kg) were participated in the study. The thirteen subjects in the AIS group had a major Cobb angle between $20.1^{\circ}$ and $49^{\circ}$. Each group was tested with the Balance Performance Monitor (BPM). The parameters for static balance were sway area, sway path, max velocity, mean balance, anterior-posterior angle, and left-right angle of each group with their eyes opened and again with their eyes closed. Both sides of the forward reach test and the lateral reach test were also performed on each group. Results from the BPM tested showed significantly increases in all parameters of static balance with those patients with AIS under the conditions where eyes were opened and closed. In the right and left forward reach test, there was no significant difference between normal and AIS groups. However, in the lateral reach test with right and left direction, there were significant differences between normal and AIS groups. For the normal subjects, there were significant differences in the parameters with sway path and anterior-posterior sway angle between the eyes opened and closed. However, there were no significant differences in the all parameters between eyes opened and closed for the AIS subjects. These results suggest that, balance programs could be used in the rehabilitation setting for intervention of AIS and evaluation of AIS. Further study is needed to measure many patients with AIS and other functional balance scales for clinical application.

  • PDF

Immediate Effects of Ankle Dorsiflexor Facilitation Dynamic Taping on Static and Dynamic Balance and Gait Speed in Stroke Patients With Foot Drop (발등굽힘근 촉진 다이나믹 테이핑이 발 처짐이 있는 뇌졸중 환자의 정적, 동적 균형과 보행 속도에 미치는 즉각적 효과)

  • Im, Jin-gu;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • Background: Foot drop is a common symptom in stroke patients. Tape applications are widely used to manage foot drop symptoms. Previous studies have evaluated the effects of static and dynamic balance and gait on foot drop using kinesiology tape; however, only few studies have used dynamic tape application in stroke patients with foot drop. Objects: The purpose of this study was to investigate the immediate effects of dynamic taping, which facilitates the dorsiflexor muscle, on static and dynamic balance and gait speed in stroke patients with foot drop. Methods: The study included 34 voluntary patients (17 men, 17 women) with stroke. The patients were randomly assigned to the experimental group (n = 17), wherein dynamic taping was used to facilitate the dorsiflexor muscle, or the control group (n = 17), wherein kinesiology taping was used. Before the taping application, velocity average, path-length average, Berg balance scale, and timed up and go test (TUG) were recorded to measure static and dynamic balance, whereas the 10-meter walk test (10MWT) was used to measure gait speed. After the taping application, these parameters were re-evaluated in both groups. Repeated measure analysis of variance was used. Statistical significance levels were set to α = 0.05. Results: Except for the 10MWT scores in the control group, significant differences were noted in all the parameters measured for static and dynamic balance and gait speed between the pre and post-test (p < 0.05). However, the parameters showed significant interaction effects between group and time in the TUG and 10MWT (p < 0.01). Conclusion: These results indicate that compared with kinesiology taping, dynamic taping used in chronic stroke patients with foot drop had a more significant effect on dynamic balance and gait speed.

Analysis of Characteristics on Small Air-Conditioning Type Evaporator (소형 공조용 증발기의 특성 해석)

  • 김재돌;윤정인;김영수;문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.573-580
    • /
    • 2001
  • When investigating optimum design of the evaporator in the refrigeration and heat pump systems, there is still lack of data for the dynamic characteristics of the evaporator, This is due to the fact that the static characteristics in the evaporator are absolutely difficult to measure and are burdened with uncertainties. In this study, the simulation works for static characteristics in the evaporator of small air conditioner are carried out to obtain the data of dynamic characteristics. In the simulation, the test evaporator is divided by two-phase evaporating region and single-phase heating region. The major parameters are refrigerant flow rate, heat transfer coefficient of air, air velocity and air temperature. The results show that the calculation method for tube length is an easy-to-use to model analysis of static characteristics and to determine state of refrigerant in the evaporator. The effects of the four parameters on the length of evaporating completed point and heat flow rate to the evaporator are clarified.

  • PDF

The Effect of Dimensions and Location of Oil Grooves on the Static Performance of a Cylindrical Journal Bearing (급유홈의 크기와 위치가 원통형 저널 베어링의 정적성능에 미치는 영향)

  • Son, Sang-Ik;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.26 no.4
    • /
    • pp.209-218
    • /
    • 2010
  • In this study, the effect of dimensions and location of oil grooves on the static performance of a cylindrical journal bearing is analyzed numerically. Axial length, circumferential length and location of oil grooves are considered as parameters. Cavitation occurs within the diverging region of a journal bearing. The distribution of cavitation region where cavitation occurs varies with dimensions and location of oil grooves and affects the performance of a journal bearing. Elrod's cavitation algorithm which implements JFO boundary conditions based on the principle of mass conservation at the interfaces between cavitation and full film region is adopted in order to consider the effect of cavitation. The result shows that parameters, especially location of oil grooves have a great effect on the static performance of a journal bearing.

FLUORESCENCE QUENCHING OF BBOT BY ANILINE IN DIFFERENT ORGANIC SOLVENTS

  • Kadadevarmath, J.S.;Giraddi, T.P.;Chikkur, G.C.
    • Journal of Photoscience
    • /
    • v.4 no.3
    • /
    • pp.105-112
    • /
    • 1997
  • The fluorescence quenching of 2, 5-di-(5-tert-butyl-2-benzoxazolyl)-thiophene (BBOT) by aniline in five different solvents namely heptane, hexane, cyclohexane, dioxane and acetonitrile has been carried out at room temperature with a view to understand the quenching mechanisms. The experimental results show positive deviation in the Stern-Volmer plots in all the solvents. In order to interpret these results we have invoked the Ground state complex and sphere of action static quenching models. Using these models various rate parameters have been determined. The magnitudes of these parameters suggest that sphere of action static quenching model agrees well with the experimental results. Hence this positive deviation is attributed to the static and dynamic quenching. Further, with the use of Finite Sink approximation model, it was possible to check these bimolecular reactions as diffusion-limited and to estimate independently distance parameter R$^1$ and mutual diffusion coefficient D. Finally an attempt has been made to correlate the values of R$^1$ and D with the values of the encounter distance R and the mutual diffusion coefficient D determined using the Edward's empirical relation and Stokes-Einstein relation.

  • PDF

Exact Static Element Stiffness Matrix of Shear Deformable Nonsymmetric Thin-walled Elastic Beams (전단변형을 고려한 비대칭 박벽보의 엄밀한 정적 요소강도행렬)

  • 김남일;곽태영;이준석;김문영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.345-352
    • /
    • 2001
  • Derivation procedures of exact static element stiffness matrix of shear deformable thin-walled straight beams are rigorously presented for the spatial buckling analysis. An exact static element stiffness matrix is established from governing equations for a uniform beam element with nonsymmetric thin-walled cross section. First this numerical technique is accomplished via a generalized linear eigenvalue problem by introducing 14 displacement parameters and a system of linear algebraic equations with complex matrices. Thus, the displacement functions of dispalcement parameters are exactly derived and finally exact stiffness matrices are determined using member force-displacement relationships. The buckling loads are evaluated and compared with analytic solutions or results of the analysis using ABAQUS' shell elements for the thin-walled straight beam structure in order to demonstrate the validity of this study.

  • PDF

Model Parameter Correction Algorithm for Predictive Current Control of SMPMSM

  • Li, Yonggui;Wang, Shuang;Ji, Hua;Shi, Jian;Huang, Surong
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1004-1011
    • /
    • 2016
  • The inaccurate model parameters in the predictive current control of surface-mounted permanent magnet synchronous motor (SMPMSM) affect the current dynamic response and steady-state error. This paper presents a model parameter correction algorithm based on the relationship between the errors of model parameters and the static errors of dq-axis current. In this correction algorithm, the errors of inductance and flux are corrected in two steps. Resistance is ignored. First, the proportional relations between inductance and d-axis static current errors are utilized to correct the error of model inductance. Second, the flux is corrected by utilizing the proportional relations between flux and q-axis static current errors under the condition that inductance is corrected. An experimental study with a 100 W SMPMSM is performed to validate the proposed algorithm.

An Analysis of Load Characteristics of Air-Lubricated Herringbone Groove Journal Bearing By Finite Element Method (공기윤활 빗살무늬 저널베어링의 부하특성에 대한 유한요소해석)

  • 박신욱;임윤철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.353-362
    • /
    • 2000
  • Herringbone groove journal bearing (HGJB) is developed to improve the static and dynamic performances of hydrodynamic journal bearing. In this study, static and dynamic compressible isothermal lubrication problems are analyzed by the finite element method together with the Newton-Raphson iterative procedure. This analysis is introduced for prediction of the static and dynamic characteristics of air lubricated HGJB for various bearing configurations. The bearing load characteristics and dynamic characteristics are dependent on geometric parameters such as asymmetric ratio, groove depth ratio, groove width ratio and groove angle.

  • PDF