• 제목/요약/키워드: static measurements

검색결과 415건 처리시간 0.024초

Results of the key comparison in absolute pressure from 1 Pa to 1000 Pa

  • Hong, Seung-Soo;Shin, Yong-Hyeon;Chung, Kwang-Hwa;A. P. Miiller
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.109-115
    • /
    • 2002
  • This paper describes a CCM key comparison of low absolute-pressure standards at seven National Measurement Institutes that was carried out during the period March 1998 to September 1999 in order to determine their degrees of equivalence at pressures in the range 1 Pa to 1000 Pa. The Korea Research Institutes of Standards and Science(KRISS) participated from 10 Pa to 1000 Pa pressure range in 1999. The primary standards, which represent two principal measurement methods, included five liquid-column manometers and four static expansion systems. The transfer standard package consisted of four high-precision pressure transducers, two capacitance diaphragm gauges to provide high resolution at low pressures, and two resonant silicon gauges to provide the required calibration stability.

  • PDF

자동차 시트의 피로도 평가를 위한 근전도 평가를 위한 근전도 측정기의 사용 (The Use of Electromyography for Fatigue Evaluation of Automotive Seats)

  • 이영신;이의신;박세진
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1997년도 춘계학술대회논문집
    • /
    • pp.10-16
    • /
    • 1997
  • The ride comfort is one of the most important indices which decide the quality of automotive seats. A subjective evaluation is the general method for comfort evaluation of automotive seats. But the subjective evaluation assess the individual sensibility using questionnaire. Therefore, a need to develop methodologies to obtain objective measurements of the fatigue evaluation is evident. In an effort to monitor muscle activity during driving electromyography (EMG) was employed. In an experimental setting the subjective evaluation was conducted using questionnaire under the static conditions (8 subjects) and the fatigue was induced in muscles using EMG under the dynamic conditions (2 drivers). The resultant EMG signals were then sampled for three different muscles. In test involving 2 subjects of similar size and build, utilizing four different automotive seats, test results support the use of EMG to quantify muscular fatigue as a viable means of objective evaluation for the different automotive seats.

  • PDF

Filter-Free Wavelength Conversion Using Mach-Zehnder Interferometer with Integrated Multimode Interference Semiconductor Optical Amplifiers

  • Kim, Jong-Hoi;Kim, Hyun-Soo;Sim, Eun-Deok;Kim, Kang-Ho;Kwon, Oh-Kee;Oh, Kwang-Ryong
    • ETRI Journal
    • /
    • 제26권4호
    • /
    • pp.344-350
    • /
    • 2004
  • We propose a filter-free wavelength conversion using a Mach-Zehnder interferometer with monolithically integrated $2{\times}2$ multimode interference semiconductor optical amplifiers (MMI-SOAs). The device has been optimized by considering a non-homogeneous carrier distribution due to the self-imaging properties of the MMI-SOA. Static measurements show an extinction ratio of up to 18 dB and an input signal rejection ratio of up to 20 dB.

  • PDF

Effect of Chemical Passivation Treatment and Flow on the Corrosion of 304 Stainless Steel in Hydrochloric Acid Solution

  • Zhao, Jie;Cheng, Cong Qian;Cao, Tie Shan
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.273-279
    • /
    • 2015
  • Effects of passive film quality by chemical passivation and solution flow on the corrosion behavior of 304 stainless steel in HCl solution were investigated using a coloration indicator, and by corrosion weight loss, electrochemical polarization and element dissolution measurements. A high redness degree suggests a low passive-film integrity for 304 stainless steel following air exposure, while the minimum redness degree for the samples after chemical passivation suggests a high passive-film integrity. In the static condition, samples subjected to air exposure exhibited a high corrosion rate and preferential dissolution of Fe. Chemical passivation inhibited the corrosion rate due to the intrinsically high structural integrity of the passive film and high concentrations of Cr-rich oxides and hydroxide. Solution flow accelerated corrosion by promoting both the anodic dissolution reaction and the cathodic reaction. Solution flow also altered the preferential dissolution to fast uniform dissolution of metal elements.

소형 터보압축기의 디퓨저 형상변화에 따른 유동특성 고찰 (Effects of Vaned Diffuser Shapes on the Flowfields of a Small-Size Turbo-Compressor)

  • 김홍식;김윤제;김철수
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.21-28
    • /
    • 2001
  • The effects of diffuser shapes on the flowfields of a small-size turbo-compressor have been investigated numerically and experimentally. The optimal design of elements shapes is important to develop the high efficiency turbo-compressor. Typical range of rotating speed for a small-size turbo-compressor is 40,000-70,000rpm. Numerical analyses were conducted to the rectangular and conical shapes of diffuser Three-dimensional, steady and viscous governing equations were solved by SIMPLE algorithm. To confirm the numerical results, the experimental measurements for the static pressure and temperature at the inlet and outlet boundaries were performed. Comparisons of these results were done, and the reasonable agreements were acquired.

  • PDF

원심형 터보기계의 임펠러-볼류트 유동간섭에 관한 실험적 연구 (Experimental investigation of impeller-volute interaction on a centrifugal turbomachinery)

  • 이경훈;주원구
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.219-225
    • /
    • 2000
  • Primary function of a centrifugal compressor volute is to serve the flow from the impeller and diffuser to pipe system. But losses in volutes at off-design lead to poor stage efficiency and reduction of operating range. This is largely caused by the interaction between the impeller and volute flow fields. The magnitude of distortion is increased as the operating point is away from the design point and, as a result, the interaction between the impeller and volute is stronger. The objective of present study is to find the characteristics of tile flow in the diffuser and volute of the centrifugal compressor with rectangular cross-sectional volute. The measurements are carried out in two cases with the existence and nonexistence of the volute casing. The detailed pressure is presented by comparing the experimental results obtained at two cases with each others.

  • PDF

소형 터보압축기의 디퓨져 형상변화에 따른 유동특성 고찰 (Effects of Vaned Diffuser Shapes on the Flowfields of a Small-Size Turbo-Compressor)

  • 김홍식;차관;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.187-192
    • /
    • 2000
  • The effects of diffuser shapes on the flowfields of a small-size turbo-compressor have been investigated by numerically and experimentally. It is important to optimal design of each elements for developing the small-size turbo-compressor Typical range of rotating speed of a small-size turbo-compressor is 40,000-70,000rpm. Numerical analyses are conducted to the rectangular and conical shapes of diffusers. Three-dimensional, steady, viscous governing equations are solved by SIMPLE algorithm. To prove the numerical results, experimental studies for the measurements of static pressure and temperature at the inlet and outlet boundaries are performed. Comparisons of these results are executed, and reasonable agreements are acquired.

  • PDF

충격파관 내 천음속 익형 유동의 가시화 (Visualization of Transonic Airfoil Flows in a Shock Tube)

  • 장호근;권진경;김병지;권순범;김명수
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.68-71
    • /
    • 2004
  • The experiments for NACA airfoils are conducted as the preliminary study for the aerodynamic characteristics of the transonic airfoil flow in the shock tube. The test section configurations were designed to use shock tube as simple and less costly experimental facility generating transonic flow at relatively high Reynolds numbers. Experiments at hot gas Mach numbers of 0.80, 0.82 and 0.84, Reynolds numbers of about $1.2\times10^6$ on airfoil chord length and angle of attack of $0^{\circ}\;and\;2^{\circ}$ were carried out by means of shadowgraph visualization method and static pressure measurements. Visualization results were compared with the corresponding results from the conventional transonic wind tunnel tests. The results of study showed that present shock tube facility is useful to study the proper performance characteristics in transonic Mach number range.

  • PDF

환형 유동을 수반하는 초음속 스월 제트 유동의 가시화 (Visualization of the Supersonic Swirl Jet with Annular Stream)

  • 김중배;이권희;;김희동
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.91-94
    • /
    • 2003
  • The present study addresses experimental results to investigate the details of the near field flow structures produced in the under-expanded, dual, coaxial, swirling, jet. The sonic swilling jets are emitted from a sonic inner nozzle and the outer annular nozzle produces the co/counter swirling streams against the primary swirling jet, respectively. The interactions between both the secondary annular swirling and primary inner supersonic swirling jets are quantified by the pilot impact and static pressure measurements, and visualized by using the Schlieren optical method. The experiment has been performed fur different swirl intensities and pressure ratios. The results obtained show that the secondary co-swirling jet significantly changes the inner under-expanded swirling jet, such as the recirculation zone, pressure distribution, through strong interactions between both the swirling jets, and the effect of the secondary counter-swirling jet on the primary inner jet is similar to the secondary co-swirl jet case.

  • PDF

복합재료 표면안테나 구조의 굽힘 피로특성 연구 (Bending Fatigue Characteristics of Surface-Antenna-Structure)

  • 김동현;황운봉;박현철;박위상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1647-1650
    • /
    • 2003
  • The Objective of this work was to design Surface Antenna Structure (SAS) and investigate fatigue behavior of SAS that was asymmetric sandwich structure. This term, SAS, indicates that structural surface becomes antenna. Constituent materials were selected considering electrical properties, dielectric constant and tangent loss as well as mechanical properties. For the antenna performance, SSFIP elements inserted into structural layers were designed for satellite communication at a resonant frequency of 12.5 GHz and final demonstration article was 16${\times}$8 array antenna. From electrical measurements, it was shown that antenna performances were in good agreement with design requirements. In cyclic 4-point bending, flexure behavior was investigated by static and fatigue test. Fatigue lift curve of SAS was obtained. The fatigue load was determined experimentally at a 0.75(1.875kN) load level. SAS concept is the first serious attempt at integration for both antenna and composite engineers and promises innovative future communication technology.

  • PDF