• 제목/요약/키워드: static coefficients

검색결과 315건 처리시간 0.026초

Implementation of a 35KVA Converter Base on the 3-Phase 4-Wire STATCOMs for Medium Voltage Unbalanced Systems

  • Karimi, Mohammad Hadi;Zamani, Hassan;Kanzi, Khalil;Farahani, Qasem Vasheghani
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.877-883
    • /
    • 2013
  • This paper discussed a transformer-less shunt static synchronous compensator (STATCOM) with consideration of the following aspects: fast compensation of the reactive power, harmonic cancelation and reducing the unbalancing of the 3-phase source side currents. The STATCOM control algorithm is based on the theory of instantaneous reactive power (P-Q theory). A self charging technique is proposed to regulate the dc capacitor voltage at a desired level with the use of a PI controller. In order to regulate the DC link voltage, an off-line Genetic Algorithm (GA) is used to tune the coefficients of the PI controller. This algorithm arranged these coefficients while considering the importance of three factors in the DC link voltage response: overshoot, settling time and rising time. For this investigation, the entire system including the STATCOM, network, harmonics and unbalancing load are simulated in MATLAB/SIMULINK. After that, a 35KVA STATCOM laboratory setup test including two parallel converter modules is designed and the control algorithm is executed on a TMS320F2812 controller platform.

1차원 지반응답해석을 통한 사면의 증폭특성 규명 (Estimation of amplification of slope via 1-D site response analysis)

  • 윤세웅;박두희
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.620-625
    • /
    • 2009
  • The seismic slope stability is most often evaluated by the pseudo-static limit analysis, in which the earthquake loading is simplified as static inertial loads acting in horizontal and/or vertical directions. The transient loading is represented by constant acceleration via the pseudostatic coefficients. The result of a pseudostatic analysis is governed by the selection of the value of the pseudostatic coefficient. However, selection of the value is very difficult and often done in an ad hoc manner without a sound physical reasoning. In addition, the maximum acceleration is commonly estimated from the design guideline, which cannot accurately estimate the dynamic response of a slope. There is a need to perform a 2D dynamic analysis to properly define the dynamic response characteristics. This paper develops the modified one-dimensional seismic site response analysis. The modified site response analysis adjusts the density of the layers to simulate the change in mass and weight of the layers of the slope with depth. Multiple analyses are performed at various locations within the slope to estimate the change in seismic response of the slope. The calculated peak acceleration profiles with depth from the developed procedure are compared to those by the two-dimensional analyses. Comparisons show that the two methods result in remarkable match.

  • PDF

정전압에 따른 클린룸 벽체에서의 입자침착 특성 (Characteristics of Particle Deposition onto the Cleanroom Wall Panel with Electrostatic Voltages)

  • 노광철;손영태;김종준;오명도
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.1033-1038
    • /
    • 2006
  • We carried out the experiments on particle deposition onto the cleanroom wall panels. And then we investigated the particle deposition characteristic coefficients for electrostatic voltages and particle size. It was found that there is little difference in characteristics of the particle deposition between the steel panel and the anti-static coating panel. In case of that the particle size is under $1.0{\mu}m$, the particle deposition characteristic coefficient becomes larger as the electrostatic voltage induced to the cleanroom wall panel is increasing. Where in case of that the particle size is over $3.0{\mu}m$, the particle deposition characteristic coefficients do not show any differences with the electrostatic voltages. It is due to that the electrostatic force is the major particle transport mechanism for submicron particles, while the gravitational settling is the major particle transport mechanism for overmicron particles when the electro-static voltages are induced to the cleanroom wall panel.

경사안내면 상에서 이송되는 볼나사-슬라이드 이송계의 마찰기인 진동해석 (Analysis of Friction-Induced Vibrations in a Ball Screw Driven Slide on Skewed Guideway)

  • 최영휴
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.88-98
    • /
    • 2014
  • A moving mass on a skewed linear guideway model to analyze the friction-induced stick-slip behavior of ball-screw-driven slides is proposed. To describe the friction force, a friction coefficient function is modelled as a third-order polynomial of the relative velocity between the slide mass and a guideway. A nonlinear differential equation of motion is derived and an approximate solution is obtained using a perturbation method for the amplitudes and base frequencies of both pure-slip and stick-slip oscillations. The results are presented with time responses, phase plots, and amplitude plots, which are compared adequately with those obtained by Runge Kutta 4th-order numerical integration, as long as the difference between the static and kinematic friction coefficients is small. However, errors in the results by the approximate solution increase and are not negligible if the difference between the friction coefficients exceeds approximately 40% of the static friction coefficient.

Combination coefficient of ESWLs of a high-rise building with an elliptical cross-section

  • Wang, Qinhua;Yu, Shuzhi;Ku, Chiujen;Garg, Ankit
    • Wind and Structures
    • /
    • 제31권6호
    • /
    • pp.523-532
    • /
    • 2020
  • As the height and flexibility of high-rise buildings increase, the wind loads become more dominant and the combination coefficient of Equivalent Static Wind Loads (ESWLs) should be considered when they are used in the structural design. In the first phase of the study, a brief introduction to the theory on the combination coefficient for high-rise buildings was given and then the time history of wind-induced responses of a 208-meter high-rise building with an elliptical cross-section was presented based on the wind tunnel test results for pressure measurement. The correlation between wind-induced responses was analyzed and the combination coefficients of ESWLs of the high-rise buildings using Turkstra's rule, and Asami's method, were calculated and compared with related design codes, e.g., AIJ-RLB, ASCE 7-10, and China Load Code for structural design. The results of the study showed that the combination coefficients from Asami's method are conservative compared with the other three methods. The results of this paper would be helpful to the wind-resistant design of high-rise buildings with elliptical cross-section.

왕겨숯과 톱밥을 이용하여 제조한 보드의 역학적 성능: 수지 및 톱밥첨가량의 영향 (Mechanical Performances of Boards Made from Carbonized Rice Husk and Sawdust: The Effect of Resin and Sawdust Addition Ratio)

  • HWANG, Jung-Woo;OH, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.696-709
    • /
    • 2020
  • 쌀의 도정과정에서 발생되는 농업부산물인 왕겨를 탄화시켜 만든 왕겨숯과 톱밥을 이용하여 수지 첨가율, 톱밥 첨가율별로 보드를 제조하고 수지와 톱밥 첨가율이 동적·정적탄성계수 및 휨강도에 미치는 영향과 동적탄성계수와 정적탄성계수 및 휨강도 사이의 관계를 조사하였다. 왕겨숯-톱밥 혼합보드의 페놀수지 첨가율이 10~25%로 증가할수록 휨성능이 증가하여 수지 첨가율이 휨성능에 크게 영향을 주었다. 톱밥 첨가율이 증가할수록 휨성능도 완만하게 증가하였지만, 톱밥첨가율과 휨강도, 동적 및 정적 휨 탄성계수 사이는 결정계수의 값(R2)은 0.4012, 0.0809, 0.1971로써 다소 낮은 상관관계를 나타내 톱밥 첨가율이 휨성능에 미치는 영향이 미비하였다. 왕겨숯-톱밥 혼합보드의 동적탄성계수와 정적탄성계수 및 휨강도 사이에 높은 상관관계가 확인되어 동적탄성계수로부터 비파괴적으로 정적탄성계수와 휨강도의 예측이 가능한 것으로 확인되었다.

영각의 변화에 대한 전개판의 정적 안정성 연구 (A study on the static stability of the otter board in relation to the angle of attack)

  • 박창두;안희춘
    • 수산해양기술연구
    • /
    • 제38권3호
    • /
    • pp.234-240
    • /
    • 2002
  • 본 연구에서는 전개판의 영각 변화에 따른 정적안정성에 관하여 이론적 해석을 하였다. 또한 전개판의 형상별 유체력에 의한 정적 안정성을 평가하기 위하여 종횡비가 다른 평판과 만곡도가 다른 종만곡판을 사용하여 회류수조에서 유체력 및 모벤트를 측정하고 형상별 압력중섬계수와 모멘트 계수를 계산하였다. 본 연구에서 얻어진 결과를 요약하면 다음과 같다. 1. 전개판의 영각($\alpha$) 변화에 따른 끌줄의 장력과 후릿줄의 장력에 의한 모멘트 변화는 전개판을 항상 정적 안정성을 가지도록 작용한다. 2. 종횡비(λ)가 0.5, 1.0, 1.5인 평판의 압력중심계 수는 영각의 증가와 함께 전연에서 중심쪽으로 이동한다. 이것은 유체력에 의한 모멘트는 항상 정적으로 안정하도록 작용한다는 것을 의미한다. 3. 종횡비가 일정(λ=1.5)하고, 만곡도(CR)가 5%, 10%, 15%, 20%인 만곡판의 유체력에 의한 압력중심계수는 영각의 증가와 함께 후연에서 전연쪽으로 이동한 다음, 다시 만곡판의 중심쪽으로 이동한다 만곡판에 작용하는 유체력에 의한 모멘트는 만곡도가 커질수록 정적으로 불안정한 영각의 범위가 증가한다.

고속 공기 포일 베어링의 정적${\cdot}$동적 특성에 관한 실험적 연구 (An Experimental Study on the Static and Dynamic Characteristics of High Speed Air Foil Bearings)

  • 조준현;이용복;김창호;임윤철
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.186-194
    • /
    • 2004
  • Experiments were conducted to determine the structural static and dynamic characteristics of air foil bearings. The housing of the bearing on the journal was driven by an impact hammer which was used to simulate dynamic forces acting on the bump loll with various leading condition. Two different bump foils (Cu-coated bump and viscoelastic bump) were tested and the static and dynamic coefficients of two bump foils compared, based on the experimental measurements for a wide range of operating conditions. The static and dynamic characteristics of air foil bearings were extracted 0rpm the frequency response function by least square method and IV(Instrumental Variable) method. The experiment was tested at 0rpm and $10,000\~16,000rpm$, and loaded on $50\~150N$. From the test results, the possibility of the application of high load and high speed condition is suggested.

  • PDF

Wind load effects and equivalent static wind loads of three-tower connected tall buildings based on wind tunnel tests

  • Ke, Shitang;Wang, Hao;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • 제58권6호
    • /
    • pp.967-988
    • /
    • 2016
  • Due to the significant aerodynamic interference from sub-towers and surrounding tall buildings, the wind loads and dynamic responses on main tower of three-tower connected tall building typically change especially compared with those on the isolated single tall building. This paper addresses the wind load effects and equivalent static wind loads (ESWLs) of three-tower connected tall building based on measured synchronous surface pressures in a wind tunnel. The variations of the global shape coefficients and extremum wind loads of main tower structure with or without interference effect under different wind directions are studied, pointing out the deficiency of the traditional wind loads based on the load codes for the three-tower connected tall building. The ESWLs calculation method based on elastic restoring forces is proposed, which completely contains the quasi-static item, inertia item and the coupled effect between them. Then the wind-induced displacement and acceleration responses for main tower of three-tower connected tall building in the horizontal and torsional directions are investigated, subsequently the structural basal and floor ESWLs under different return periods, wind directions and damping ratios are studied. Finally, the action mechanism of interference effect on structural wind effects is investigated. Main conclusions can provide a sientific basis for the wind-resistant design of such three-tower connected tall building.

벨마우스 깊이가 다른 3차원 소형축류홴의 공력특성에 대한 대규모 와 모사 (Large Eddy Simulation on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan with the Different Depth of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.19-25
    • /
    • 2015
  • The unsteady-state, incompressible and three-dimensional large eddy simulation(LES) was carried out to analyze the aerodynamic performance of three-dimensional small-size axial fan(SSAF) with the different depth of bellmouth. The static pressure coefficients analyzed by LES predict a little bit larger than measurements except stall region regardless of the installation depth between SSAF and bellmouth. Moreover, static pressure efficiencies analyzed by LES show about maximum 30% at the actual operating point ranges, but measurements do not. Therefore, if the blades of conventional SSAF have some more rigidity and complete dynamic balance, the aerodynamic performance of SSAF will be some more improved. In consequence, LES shows the best prediction performance in comparison with any other Reynolds averaged Navier-Stokes(RANS) method.