• Title/Summary/Keyword: starting time

Search Result 1,527, Processing Time 0.025 seconds

The Noise Robust Algorithm to Detect the Starting Point of Music for Content Based Music Retrieval System (노이즈에 강인한 음악 시작점 검출 알고리즘)

  • Kim, Jung-Soo;Sung, Bo-Kyung;Koo, Kwang-Hyo;Ko, Il-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.9
    • /
    • pp.95-104
    • /
    • 2009
  • This paper proposes the noise robust algorithm to detect the starting point of music. Detection of starting point of music is necessary to solve computational-waste problem and retrieval-comparison problem with inconsistent input data in music content based retrieval system. In particular, such detection is even more necessary in time sequential retrieval method that compares data in the sequential order of time in contents based music retrieval system. Whereas it has the long point that the retrieval is fast since it executes simple comparison in the order of time, time sequential retrieval method has the short point that data starting time to be compared should be the same. However, digitalized music cannot guarantee the equity of starting time by bit rate conversion. Therefore, this paper ensured that recognition rate shall not decrease even while executing high speed retrieval by applying time sequential retrieval method through detection of music starting point in the pre-processing stage of retrieval. Starting point detection used minimum wave model that can detect effective sound, and for strength against noise, the noises existing in mute sound were swapped. The proposed algorithm was confirmed to produce about 38% more excellent performance than the results to which starting point detection was not applied, and was verified for the strength against noise.

A Fault Detection and Location Algorithm Using a Time Constant for DC Railway Systems (시정수를 이용한 직류철도급전계통에서의 고장판단 및 고장점표정 알고리즘)

  • 양언필;강상희;권영진
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.563-570
    • /
    • 2003
  • When a fault occurs on railway feeders it is very important to detect the fault to protect trains and facilities. Because a DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases at one time. So the type of $\Delta$I/ relay(50F) was developed using the different characteristics between the load starting current and the fault current. The load starting current increases step by step so the time constant of each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. If a fault occurs on DC railway systems it is necessary to find a fault location to repair the faulted system as soon as possible. The second aim of the paper is to calculate the accurate fault location using Kirchhoff's voltage law.

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Study on the Ageing of Glow Starter for Fluorescent Lamp (형광등용 점등관의 에이징에 관한 연구)

  • 지철근
    • 전기의세계
    • /
    • v.22 no.2
    • /
    • pp.23-27
    • /
    • 1973
  • An initial starting voltage, ignition time, glow current and blink of the flow starter are changed rapidly in initial using. therefore an ageing is required to stabilize the initial characteristics. According to the experiments, it is proved that the ageing time for the starting voltage and glow current takes 3 minutes and 5 minutes for ignition time and blink.

  • PDF

A Study on Starting Characteristic and Improvement for High Power Motor with Tunnel Boring Machine (TBM용 대용량 전동기의 기동 특성 및 개선 관한 연구)

  • Kim, Tae-Kue;An, Joon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • Tunnel Boring Machine's Technology has depends mostly on imports, currently domestic technology development was proceeding. There are many technologies in this field, above all, the large-capacity motor drive technology required for excavation is one of the core technologies. In particular, when several large motors are simultaneously starting, there are many problems due to a large starting current at that time, and it is difficult to design and operate a power receiving facility. In this paper, A method of reducing the starting current by using the regenerative power generated by the deceleration of the motor has been studied. To verify this proposal, we designed the induction motor controller using CAE based power simulation tool and verified the results of the proposed method by applying the reduced model. As a result, it is possible to reduce the maximum starting current and shorten the start-up time. Moreover, even if several motors are connected to one bank, it is proved that the method can be efficiently operated by using the sequential braking / starting sequence. In the case of a power system in which a large capacity electric motor such as a tunnel excavation system is driven, the results of this study are expected to be a stable and effective method for solving the start-up current problem and designing the power receiving facility.

A Protection Scheme for DC Railway Systems (DC철도 급전계통 보호시스템 구성)

  • Kwon, Y.J.;Kang, S.H.;Oh, K.H.;Lee, J.K.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • A DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. So the type of ${\Delta}I$ relay(50F) was developed using the different characteristics between the load starting current and the fault current. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. Secondly, to compose a protection scheme for DC railway systems is presented in this paper.

  • PDF

Analysis of Starting Torque and Speed Characteristics for Squirrel Cage Induction Motor According to Material Properties of Rotor Slot

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.6
    • /
    • pp.328-333
    • /
    • 2015
  • Squirrel cage induction motors have mostly been used for their small capacity because the starting torque is smaller than the starting current during start-up. However, as more and more mid-to-large capacity motors are developed, the demands for improvements in performance characteristics have also increased. In this study, the starting characteristics of squirrel cage induction motors were analyzed based on the rotor materials and shapes using a finite element method to provide design data suitable for different use purposes and capacities. We further completed analysis by combining electromagnetic equations deduced from Maxwell’s equations and the circuit equations of stators and rotors. A moving coordinator was introduced to rotate the rotor during the analysis, and the torques calculated via the finite element method were combined with the motion equations to calculate the position and angular velocity of the rotors at the next time, thereby analyzing the transient characteristics. The analysis results of the transient characteristics were applied to a 3-phase 4-pole 5-hp induction motor to calculate the starting torque, speed, and rotation angle of the rotors. In the reference model, the materials and shapes of the rotor slot were changed to copper and silicon copper and a deep slot, shallow slot, and long-neck-shaped slot.

Effect of Strarting Structures and Intercritical Annealing on Low Temperatures Mechanical Properties of a HSLA Steel (초기조직 및 이상역열처리가 저합금 고강도강의 저온기계적 성질에 미치는 영향)

  • Cho, H.K.;Park, K.G.;Shin, D.H.;Maeng, S.C.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.7 no.1
    • /
    • pp.53-60
    • /
    • 1994
  • Austenite formation and Low temperatures mechanical properties of HSLA steel of different starting structures have been studied by intercritical annealing(IA). The different starting structures are: ferrite+pearlite(FP1), martensite(M1), cold worked ferrite+pearlite(FP2) and cold worked martensite(M2). In most cases tensile strength and elongation was increased by decreasing the testing temperatures regardless of the IA time. Tensile strength of the cold worked starting structures was higher than that of the non-cold worked starting structures. However not any noticeable difference in elongation was found between two cases. Low temperatures impact properties were affected by the starting structures. Charpy V-notch impact transition temperatures of the M-starting structures were around $-40^{\circ}C$, and those of the FP starting structures were around $-10^{\circ}C$. Impact energy was lower in the cold worked specimens than in the non-cold worked specimens at the same starting structures. DP structure obtained from the M-starting structure has shown superior low temperatures mechanical properties than the DP structure obtained from the FP-starting structure.

  • PDF

Environmental Factors Affecting the Start of the Dawn Chorus of Wild Birds and the Differences between Each Species (야생조류 새벽 지저귐 개시에 영향을 주는 환경요인과 종간 차이)

  • Ki, Kyong-Seok;Hong, Suk-Hwan;Gim, Ji-Youn
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.344-352
    • /
    • 2015
  • This study aims to identify the difference in the starting time of the dawn chorus of different species of birds and related environmental conditions. For this study, the bird songs were recorded every 2 hours a day starting from 2 hours before sunrise for a whole spring season (from April to June, 2014) in Korea. The recorded sounds were analyzed to find the starting time of each species' song by sonogram pattern using a sound analyzing program (Adobe Audition CC). To analyze the relationship between the environmental conditions and the time of the birdsong of each species, we collected the data of environmental conditions: daily precipitation, Julian date, time of sunrise and moonrise, temperature data and twilight time from the Korea Meteorological Office. As a result of this study, it was found that there are several statistical correlation between the starting time of the birdsong and environmental conditions (every environmental condition except daily precipitation and time of moonrise). Also, the difference of the starting time among each species were identified. The species were divided into 3 groups (early, mid and late) by their wake-up time. Ring-necked pheasant and yellow-throated bunting were categorized as 'Early' group and all woodpeckers were categorized as'Late' group. This study is significant as it first presented a classification of wild birds in Korea by the starting time of their dawn chorus. However, further studies are required to identify why each species to do their dawn singing at different times.

A study on shortest problem between specified nodes with multiple travel time (다수개의 여행시간이 주어진 경우의 지정된 마디간의 최단경로 문제)

  • 이명석;박순달
    • Korean Management Science Review
    • /
    • v.7 no.2
    • /
    • pp.51-57
    • /
    • 1990
  • The purpose of this thesis is to find the shortest path between two nodes on an acyclic network where the arc costs are determined by the starting time at the starting node of the arc. A branch and bound method for optimal solutions and a heuristic method is developed. In heuristic method Dijkstra algorithm is modified to maintain the minimum arrival times of maximum informations in the each time period at each node and is updated by the result with the insertion technique. Expermetal results among two methods are presented with regard to run time and solution qualities.

  • PDF