• Title/Summary/Keyword: start condition

Search Result 431, Processing Time 0.027 seconds

The thermal cycle degration of MEA in PEMFC under cold start condition (냉시동 환경에서 thermal cycle이 FEMFC의 MEA 열화에 미치는 영향)

  • Rhee, Jun-Kee;Seo, Dong-Ho;Jeon, Yu-Kwon;Shul, Yong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.412-414
    • /
    • 2009
  • In recent times, starting up polymer electrolyte membrane fuel cells(PEMFC) in sub-zero condition is a great challenge of fuel cell electric vehicle(FCEV). The water produced in a cathode during PEMFCs operate. The water changes into the form of solid/ice in sub-zero temperatures and this makes trouble in PEMFC cells. Voltage of PEMFC drops and cold startup is failed. This paper describes an experimental study on the effect of thermal cycle to degradation of MEA in PEMFC.

  • PDF

A Analytic Study of Structural Factors in Saemanl Mini-Library (새마을문고의 구성요소에 대한 실태분석)

  • 전재봉
    • Journal of Korean Library and Information Science Society
    • /
    • v.11
    • /
    • pp.211-240
    • /
    • 1984
  • The Saemaul Mini-Library system had to start as a purely voluntary grass-roots movement without a tax su n.0, pport. In other words, it had to depend on voluntary contributions in time and labor by the reading club members for its finance and daily maintenance and operation. The purpose of the study is to analyse the actual condition of a Saemaul Mini-Library, which is established in a rural and a fishing village. To meet this purpose, I will survey the function and the meaning of a Saemaul Mini-Library and the main tendency of it-now did it start and how did it develop and I will analyse the general condition of structural factors (establishment, materials, reading club) in a Saemaul Mini-Library.

  • PDF

Effect of Exhaust Heat Exchanger on Catalytic Converter Temperature in an SI Engine (가솔린 엔진의 배기 열교환기가 촉매 온도에 미치는 영향에 관한 연구)

  • 이석환;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.9-16
    • /
    • 2004
  • Close-coupled catalyst (CCC) can reduce the engine cold-start emissions by utilizing the energy in the exhaust gas. However, in case the engine is operated at high engine speed and load condition, the catalytic converter may be damaged and eventually deactivated by thermal aging. Excess fuel is sometimes supplied intentionally to lower the exhaust gas temperature avoiding the thermal aging. This sacrifices the fuel economy and exhaust emissions. This paper describes the results of an exhaust heat exchanger to lower the exhaust gas temperature mainly under high load conditions. The heat exchanger was installed between the exhaust manifold and the inlet of close-coupled catalytic converter. The exhaust heat exchanger successfully decreased the exhaust gas temperature, which eliminated the requirement of fuel enrichment under high load conditions. However, the cooling of the exhaust gas through the heat exchanger may cause the deterioration of exhaust emissions at cold start due to the increment of catalyst light-off time.

Analysis and Design of the Single-phase Line Start Permanent Magnet Motor Considering Overhang Effect (오버행 효과를 고려한 단상 유도동기전동기의 특성해석 및 설계)

  • Kang, Han-Byul;Kim, Byung-Taek;Baek, Soo-Whang;Kim, Hong-Seok;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.49-56
    • /
    • 2009
  • This paper shows the characteristic analysis of single-phase line start permanent magnet (LSPM) motors considering the overhang structure. To achieve the low-cost design of an LSPM motor, the overhang structure is adapted for the rotor with a constraint of a fixed magnet volume. To obtain the dynamic and steady performance of the motor, the circuit parameters are extracted using the 3D-static FEM(Finite Element Method) and the d-q equivalent circuit is used. The performance of the model with overhang is compared with the conventional model without overhang on the condition that both models have a fixed volume for the permanent magnet.

Longitudinal Tension Control at Start and Stop in a Multi-span Continuous Process System (변속시의 멀티 스팬 연속 공정 시스템의 장력제어)

  • 신기현;권순오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.584-589
    • /
    • 1994
  • A time-varying nonlinear mathematical model was derived to consider the effect of change in roll radius on tension varation during winding and unwinding. A variable-gain PID controller was designed for tension control at start and stop in a multi-span continuous process system. The controller gains are updated at every control loop as roll radii continuously change. Computer simulation was carried out by using the mathematical model and the controller developed for a typical operating condition including acceleration and deceleration. When the variable-gain PID controller was used, the tension control performance was improved compared with that of existing control method during start-up and stop.

  • PDF

Determination of Phase Converter Reactances for Monocyclic-start Induction Motor (모노사이클릭기동 유도전동기의 상변환기 리액턴스 결정)

  • Kim, Do-Jin;Jwa, Chong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • This paper describes a simple and straightforward method to determine phase converter reactances for the monocyclic start induction motor which have two different phase converters. In order to determine two reactances, two kinds of simultaneous equations with two unknown reactances at a specified speed are set up by the condition of balance operation. From these equation, these unknown reactances can be solved directly using the application software without any algebraic calculation. The applicability of this method is investigated by comparing with the known method by using the computed results at the starting and rated speed, and the results show good agreement each other. Using these results, the performance characteristics of this motor are computed and compared with three phase balance operation of induction motor.

Study on Prevention of Drowsiness Driving using Electrocardiography(LF/HF) Index (심전도(LF/HF)를 활용한 졸음운전 예방 연구)

  • Moon, Kwangsu;Hwang, Kyungin;Choi, Eunju;Oah, Shezeen
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.56-62
    • /
    • 2015
  • The purpose of this study was to identify the relationship between the index of Electrocardiography(LF/HF) and the occurrence of drowsiness driving while driving in a simulated situation. Participants were 31 undergraduate students with an experience in driving and they participated 30 minutes driving under enough sleep condition and 1 hour under the sleep deprivation condition. The Euro Truck Simulator II was used for driving simulation task and ECG and perceived drowsiness of each participants were measured during two driving conditions. Perceived sleepiness recorded by the checklist every 10 minutes and ECG data extracted before and after 15 seconds of every 10 minutes to verify the relationship between two variables. The results showed that the level of perceived sleepiness under sleep deprivation condition was higher than that under the enough sleep condition, and the level of LF/HF under sleep deprivation condition was lower than that under the enough sleep condition. In addition, the result of analysis of repeated measure ANOVA for ECG indicated that authentic sleepiness revealed in 20 minutes after the start of driving under the sleep deprivation condition. However, the result of perceived drowsiness indicated that authentic sleepiness revealed in 30 minutes after the start of driving. These result suggest that the time difference between biological and perceived response on drowsiness may be exist. Finally, the significant negative correlation between the LF/HF level and perceived drowsiness was observed. These findings suggest that ECG(LF/HF) can be an possible index to measure drowsiness driving.

Dynamic Analysis of Topside Module in Lifting Installation Phase

  • Lee, Jong-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.7-11
    • /
    • 2011
  • The installation phase for a topside module suggested can be divided into 9 stages, which include start, pre-lifting, lifting, lifted, rotating, positioning, lowering, mating, and end of installation. The transfer of the topside module from a transport barge to a crane vessel takes place in the first three stages, from start to lifting, while the transfer of the module onto a floating spar hull occurs in the last three stages, from lowering to the end. The coupled multi-body motions are calculated in both calm water and in irregular waves with significant wave height (1.52m), with suggested force equilibrium diagrams. The effects of the hydrodynamic interactions between the crane vessel and barge during the lifting stage have been considered. The internal forces caused by the load transfer and ballasting are derived for the lifting phases. The results of these internal forces for the calm water condition are compared with those in the irregular sea condition. Although the effect of pitch motion on the relative vertical motion between the deck of the floating structure and the topside module is significant in the lifting phases, the internal force induced pitch motion is too small to show its influence. However, the effect of the internal force on the wave-induced heave responses in the lifting phases is noticeable in the irregular sea condition because the transfer mass-induced draught changes in the floating structure are observed to have higher amplitudes than the external force induced responses.

A Study on the Start-up of the Water/Steam Receiver for Solar Power Tower (타워형 태양열 흡수기의 시동특성에 관한 연구)

  • Seo, Ho-Young;Kim, Jong-Kyu;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.157-160
    • /
    • 2008
  • Solar receiver in the solar power tower system has a similarity to a boiler of the thermal power plant in many aspects. However Boiler is operated long time without stopping while solar receiver repeats start and stop every day. The objective of this study is to investigate start-up characteristics of solar receiver. The experimental device was constructed in a bench scale. Basic experimental condition of water/steam was set by 25 bar and $223^{\circ}C$. Initially, the heat was added into risers only, then another experiment with input into drum additionally was done. When the heat flux was valid only risers, it took about 300 minutes until the water temperature in drum reached $223^{\circ}C$. Water temperature of drum was increased by $44^{\circ}C$/hr with 91.14 g/s of water circulation. With additional heat input into drum, 200 minutes was required to reach $223^{\circ}C$. In this case temperature was increased $66^{\circ}C$/hr with 96.5 g/s of water circulation.

  • PDF

Estimation of Occupational Accident Rate about Start-up Establishment and Analysis of Characteristics about Occurrence (신생사업장 재해율 및 재해발생형태 분석)

  • Kim, Young Sun;Koo, Kwon Ho;Choe, Seong Weon;Kwon, Oh Jun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.83-89
    • /
    • 2012
  • In order for start-up establishment to enter the business market, it has to get over the first mover advantage of the existing establishment. As a result, its working condition deteriorates and a great deal of occupational accidents take place. Based on 2009 standard, the occupational accident rate of start-up establishment is 1.28%, which is two times higher than existing establishment and the gap between manufacturing and service industry has been getting wide. For the characteristic of injured person in start-up establishment, it is showed that the occupancy rate of women and people with less than 30 age starting out in a career is high and the occupancy rate of occupational accident for holiday and night work is high. Therefore, the act for occupational accident prevention is needed in the early period of business and underprivileged group for occupational accident.