• 제목/요약/키워드: standing column well

검색결과 37건 처리시간 0.03초

관정간 도수통로를 설치한 개방형 지열 시스템의 냉방성능 실험 (Performance Analysis for Open-loop Geothermal System with Spill-way technology by Real-scale Experiment)

  • 김홍교;배상무;남유진;전운;오종현;이병호
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.186-194
    • /
    • 2018
  • A ground-source heat pump system (GSHP) is more energy efficient than other heat-source systems because it uses annual constant underground and water temperatures. Especially, two-well geothermal systems using groundwater as the heat source can achieve higher performance than closed-loop geothermal systems. However, performance of two-well geothermal systems is decreased by occurring overflow according to scale during long-term operations. Therefore, this study presents a two-well pairing geothermal system that controls the groundwater level of a diffusion well. In addition, a two-well pairing geothermal system and an SCW geothermal system were installed, and a comparative analysis of cooling performance depending on system operation under the same load conditions was conducted. The result was that the average heat pump coefficient of performance (COP) of the two-well pairing system was 6.5, and the entire system COP was 4.3.

Balancing Well 교차혼합 지중열교환기의 스마트 냉난방 히트펌프 시스템의 성능평가에 관한 연구 (Study on the Performance Evaluation of Smart Heating and Cooling Heat Pump System in a Balancing Well Cross-Conditioned Ground Heat Exchanger)

  • 이창희;김동규;유병석;김부일
    • 신재생에너지
    • /
    • 제16권4호
    • /
    • pp.41-48
    • /
    • 2020
  • This study performed a single hole operation method using a balancing well-cross-mixed underground heat exchanger, and conducted thermal performance studies of an SCW-type underground heat exchanger using a two-well. The study attempted to change the existing operating method of the two adjacent SCW underground heat exchangers with one ball each. The SCW-type geothermal heat exchanger is considered to enable up to 20% of bleed discharge at maximum load, which makes groundwater usage unequal. The efficiency factor of the geothermal system was improved by constructing the discharged water by cross-mixing two balancing wells to prevent the discharge of groundwater sources and keep the temperature of the underground heat exchanger constant. As a result of the cooling and heating operation with the existing SCW heat exchange system and the balancing well-cross-mixed heat exchange system, the measured performance coefficient improved by 23% and 12% in cooling and heating operations, respectively. In addition, when operating with a balanced cross-mixing heat exchange system, it has been confirmed that the initial basement temperature is constant with a standard deviation of 0.08 to 0.12℃.

Simulated Moving Bed Chromatography의 시각적 설명 (Visual Demonstration of Simulated Moving Bed)

  • 오난숙;이종호;김진일;구윤모
    • Korean Chemical Engineering Research
    • /
    • 제43권3호
    • /
    • pp.360-365
    • /
    • 2005
  • SMB는 연속 크로마토그래피 공정으로써 회분식 크로마토그래피보다 이동상의 소비를 줄이고 높은 농도, 높은 수율의 생산성의 장점을 가지고 있다. 그러나 운전상의 복잡성 때문에 이 공정을 이해하기 어렵다. 본 실험에서는 서로 다른 색깔을 지닌 두 물질의 분리를 시도함으로써 공정의 이해를 용이하게 하였다. 실험에서 사용된 물질은 Blue dextran과 Orange G로서 각각 파란색과 오렌지 색을 띤다. 실험은 4개의 존으로 구성된 SMB로써 zone VI에서 zone I으로 재순환 되지 않는 열린 루프계가 적용되었다. 운전 조건은 Standing wave design를 이용하였으며 extract와 raffinate에서 높은 순도와 수율을 가질 수 있도록 디자인하였다. 단일 칼럼을 이용한 실험을 통해서 여러 유량에서 비선형 흡착 평형식과 실험식으로부터 물질전달계수를 얻었다. Extract와 raffinate의 농도분포 곡선은 모사 결과와 거의 일치하였다. Extract와 raffinate의 순도는 99.49%와 98.89%이며 두 물질의 수율은 모두 98%였다.

수주지열정(SCW)을 이용한 천부지열 냉난방시스템 설계지침 (Design Guidlines of Geothermal Heat Pump System Using Standing Column Well)

  • 한정상;한혁상;한찬;김형수;전재수
    • 자원환경지질
    • /
    • 제39권5호
    • /
    • pp.607-613
    • /
    • 2006
  • 내 수문지열계 가운데 수주지열정(SCW)시스템을 합리적으로 설치이용할 수 있는 조건들은 심도별 지온증가율이 명확하고($2^{\circ}C/100m$심도), 기존의 지하수 열펌프가 필요로 하는 순환수의 유량에 비해 최소 $10{\sim}30%$의 중온의 심부지하수가 산출될 수 있어야 하며, 순환수를 공내로 재주입시 공내붕괴가 일어나지 않는 견고한 암석들이 존재 하여야 한다. 수주지열정의 1개공당 굴착심도는 평균 $400{\sim}500m$이며, 이로 부터 개발가능한 지열에너지는 공당 약 $30{\sim}40RT$ 규모인데 비해 1개 수직지중열교환기가 공급가능한 지열에너지는 $2{\sim}3RT$ 정도이다. 즉 수주지열정 1개공은 $10{\sim}15$개의 수직지중열교환기 역할을 한다. 따라서 이 방식은 수직루프 설치장소의 공간 문제를 해소할 수 있는 유일한 대안으로 인식되어, 현재 전국 각지에서 많은 수의 SCW들이 무분별 하게 비과학적으로 설치되고 있다. 이와 같이 해당지역 수문지열계의 수리 지질학적인 특성과 열적인 특성을 명확히 파악하지 않은 상태에서 수주지열정을 설계 시공하는 경우에 나타날 문제점들은 추후 합리적인 천부지열 개발 이용에 지대한 장애요인이 될 것이다. 따라서 본고는 국내 수문지열계에 적합한 수주지열정을 설계 하는데 있어 필요한 일종의 지침서를 제시하기 위해 작성되었다.

지하수 부존지역에서 최적 지열에너지 활용방식 수치 모의 (Numerical Simulations for Optimal Utilization of Geothermal Energy under Groundwater-bearing Conditions)

  • 김진성;차장환;송성호;정교철
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.487-499
    • /
    • 2014
  • 최근 지열에너지 활용 증가 추세와 더불어 지하수 부존량이 풍부한 지역에서 수직개방형의 효율이 더 높다는 연구결과가 제시됨에도 불구하고, 국내 지열냉난방시스템의 열교환 방식은 수직밀폐형 방식이 주를 이루고 있다. 따라서, 본 연구에서는 지하수 부존량이 풍부한 지역에서 수직개방형 방식의 효율성을 검증하기 위하여, 수리지질 및 열적 특성을 반영한 최적의 지열에너지 활용 방식을 수치 모의하였다. 1차 모의 결과, 지하수 부존량이 풍부한 지역에서 지열냉난방시스템을 활용하는 경우 수직밀폐형보다 지하수를 직접 이용하는 수직개방형이 더욱 효과적인 것으로 분석되었으며, 수직개방형 중에서는 SCW (standing column well)형 보다는 주입정과 추출정이 분리된 복수관정형에서 지반과 열교환을 통해 얻을 수 있는 주입수와 추출수의 온도차 (${\Delta}$)가 커 더욱 효율적인 것으로 나타났다. 2차 모의에서는 수직개방형 지열에너지 공급방식인 단일관정형, SCW형, 복수관정형을 대상으로 열 이송, 이격거리 및 유량, 지하수 수리경사 등을 고려한 최적의 활용 방식을 검토하였으며, 이를 바탕으로 지열냉난방시스템의 지중 열교환 방식 선정 시 활용할 수 있는 흐름도를 제시하였다. 본 연구결과 제시된 다양한 선정 기준을 기초로 실제 선정 시에는 전체 지열냉난방 시스템에 대한 COP (coefficient of performance) 계산 및 세부적인 타당성 검토가 필요할 것으로 판단된다.

모니터링 및 시뮬레이션을 통한 SCW형 지열 시스템의 성능인자 분석에 관한 연구 (Study on the performance analysis of SCW geothermal system by simulation and monitoring)

  • 이상준;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권2호
    • /
    • pp.8-15
    • /
    • 2013
  • Recently, an interest in the use of renewable energy has been growing up due to the rise of raw material price, international oil price and depletion of fossil energy. Ground source heat pump system has a high efficiency by using the constant temperature of underground and various types of the systems have been installed and utilized in the building. there are few studies on the system performance factors in the SCW system. Furthermore, even though the performance of the system depends on the temperature of heat source, the research on their relationship is rare. In this research, in order to analyze the performance factor for the open-loop system the monitoring of the real building with the standing column well systems and the simulation with building model were conducted.

지열 Hybrid System 개발을 통한 대형 공동구조물 지열에너지 적용성 평가 (Application of the Geothermal Hybrid System for Huge Size Common Structures with Heating & Cooling System)

  • 박시삼;나상민;박종헌;이건중;김태원;김승엽
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.588-591
    • /
    • 2009
  • Ground source heat pump system; GSHPs is close to most practical use for early stage investment cost and energy efficiency in new renewable energies, and currently considered utilizing to the heat and cooling system of a building. Particularly, the case to utilize 'Standing Column well heat source gathering method' in the open standards process to have the excellent capability of gathering geothermal source is increased. But the research for the optimal design technology and the assessment of a pollution level of the ground to utilize a single well for gathering geothermal is insignificant and the design is insufficient. The heating and cooling system and the equipment to utilize a large size residential development to have over 1000 households have not developed yet. Therefore, our company developed 'geothermal hybrid system' which can construct the heat and cooling system using geothermal energy for a large size residential development of over 1000 households and conducted the evaluation of economic feasibility. Moreover we developed automatic equipment for gathering geothermal source and PLC (Programmable logic controller) to have optimal efficiency and FCU (fan coil unit) considering the floors of large size apartments.

  • PDF

개방형 지열 히트펌프 시스템의 운전 특성 (Operation Characteristics of Open Type Geothermal Heat Pump)

  • 임효재;공형진;송윤석;박성구
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교 (Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions)

  • 김진성;송성호;정교철
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 국내에서 열물성에 관한 연구는 지역별, 암종별 열물성 파악을 위주로 진행되었으나, 지열냉난방시스템 설계 시에 실시하는 TRT (thermal response test)의 열전도도와 차이가 크게 나타남에 따라 본 연구에서는 지하수 부존량이 풍부한 지역에서 시료를 통한 열전도도와 TRT를 통한 열전도도를 비교하였다. 토양 시료의 열전도도는 1.32 W/m-K, 암석 시료의 열전도도는 2.88 W/m-K로 나타났으며, TRT로 측정된 열전도도는 3.13 W/m-K로 나타나 암석 시료보다 약 10% 정도 높게 나타났다. 연구지역은 지하수가 풍부하고 0.01의 수리경사를 가지고 있어 이 차이는 지하수 흐름에 의한 영향이라고 판단된다. 라인소스(line source) 이론에 따르면 TRT는 지반의 순수한 열전도도를 산정하는 것이 목적이므로, 국내 SCW (standing column well)형의 TRT는 라인소스 이론에 적합하지 않으며 지열냉난방시스템 설계 시에는 시료를 통한 열전도도값을 사용하는 것이 타당하다고 판단된다.

열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석 (An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.512-520
    • /
    • 2020
  • 개방형 지중열교환기(SCW)는 수직 밀페형 지중열교환기에 비해 높은 용량과 효율을 갖고 있어 최근에 우리나라에서 많이 보급되고 있는 추세이다. SCW형 지중열교환기의 여러 설계 및 운전변수 중 블리딩 운전이 지중 열전도율, 보어홀 열저항 등 열성능 개선에 가장 효과가 큰 것으로 보고되고 있다. 본 연구에서는 SCW형 지중열교환기가 설치된 현장의 열응답시험 결과를 기반으로 블리딩해석 모델을 정립하고 블리딩율 및 지하수 유입수의 위치변화가 SCW형 지중열교환기 열성능에 미치는 영향을 수치해석을 통하여 고찰하였다. 해석결과 지하수가 지중열교환기 상부에서 유입될 경우 지중열교환기 순환수의 시간에 따른 온도증가는 블리딩율이 증가함에 따라 낮아지는 경향을 보였으며, 지중 열전도율은 30% 블리딩율에서 179% 증가하는 결과를 보였다. 반면에 지하수가 지중열교환기 하부에서 유입될 경우 지중열교환기 순환수는 지중과 먼저 열교환을 한 후 유입수와 하단에서 혼합되기 때문에 지중열교환기 순환수의 온도증가는 상부 유입의 경우보다 적으며 블리딩율이 약 10%를 초과하면 일정하게 유지되는 경향을 보였다.