• Title/Summary/Keyword: standardized test

Search Result 1,001, Processing Time 0.024 seconds

A Study on the Distribution of Tongue Colors and the Correlation of Tongue Colors with the Clinical Laboratory Parameters (설색의 분포 및 설색과 임상병리검사 결과의 연관성에 대한 연구)

  • Yim, Je-Min;Nam, Woo-Jin;Yun, Yong-Jae;Lee, Sang-Min;Kang, You-Gyung;Kim, Won-Il
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.71-85
    • /
    • 2013
  • Objectives : The aim of this study was to evaluate the distribution of tongue color and the correlation of the tongue colors with clinical laboratory parameters. Methods : Statistical analysis on the frequency of each tongue color and the results of the clinical laboratory parameters in each tongue color group. Results : Tongue colors that appeared most frequently were 702c, 695c, 493c, 694c, 701c, 500c, 7432c, 7431c, 7634c, 7419c in that order. Following them, 494c and 507c were rarer colors, and 501c, 673c, 687c, 693c, 696c, 703c, 7418c were equally rarest colors. Among each tongue color group, a significant difference was found in the result of complete blood cell count (CBC). The level of red blood cell (RBC) of 7432c group was significantly higher than that of the other groups except 694c group. The level of hemoglobin (Hb), hematocrit (Hct) of 7432c group were significantly higher than those of all the other groups. The level of RBC of 7431c group was lowest and significantly different from 694c, 7432c group. In results of the other tests were not significantly different. However the level of total cholesterol was higher in 695c, 694c, 500c group, and the level of triglyceride was higher in 500c, 7431c, 694c group. Those four colors have a low chroma and 7431c, 695c take blue violet color. Conclusions : The tongue color is distributed throughout following colors by order of frequency: 702c, 695c, 493c, 694c, 701c, 500c, 7432c, 7431c, 7634c, 7419c, 708c, 494c, 507c, 501c, 673c, 687c, 693c, 696c, 703c, 7418c. Some parameters of CBC has a significant correlation with some tongue colors. Other results including lipid profile, renal function test, and liver function test had no significant difference according to tongue color. However, the colors which have low chroma or take blue violet color tented to be higher in the levels of total cholesterol and triglyceride.

Standardization of the Preparation Methods for Hwajeun (I) - focused on the volume and temperature of water added- (화전 조리법의 표준화를 위한 조리과학적 연구 (I) - 첨가하는 물의 양과 온도를 중심으로 -)

  • 이승현;장명숙
    • Korean journal of food and cookery science
    • /
    • v.17 no.3
    • /
    • pp.237-245
    • /
    • 2001
  • The purpose of this study was to develop a standardized recipe of Hwajeun(glutinous rice pancake with flower) by evaluating various methods appeared in the literature. For this purpose, the effects of the volume and temperature of water used to make dough on the sensory and rheological characteristics of Hwajeun were investigated. This experiment consisted of sensory evaluation in acceptance and intensity(appearance, color, moistness, softness, chewiness, adhesiveness, taste and overall preference), objective evaluation by using texture analyser, color difference meter and measurement of water content and oil absorption ratio. The loss ratio of moisture contents between dough and cooked Hwajeun were 2.4 ~2.8%, and the oil absorption ratio of Hwajeun made by 2$0^{\circ}C$water for kneading increased in proportion to the increment of water added(p<0.01). In terms of color, b value of Hwajeun made by 104$^{\circ}C$ salted water for kneading showed higher value compared to the others. In the two bite compression test, adhesiveness, springiness, gumminess and chewiness of Hwajeun made by 2$0^{\circ}C$ water(36%) for kneading showed significantly(p<0.05) high value among the samples. As a result of sensory evaluation, Hwajeun made with 27% of 104$^{\circ}C$ salted water for kneading was most preferred in softness, chewiness, taste and overall preference

  • PDF

The Study about Improvement of Neuro Energy Decreased by Energy Saving (에너지절감에 의해 감소되는 뉴로에너지의 증강에 관한 연구)

  • Kim, Myung-Ho;Kang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.715-721
    • /
    • 2018
  • This study examined energy saving and elevating the worker's neuro energy (comfort, concentration, physical, and psychological stability) by compensating for the unpleasant tactile sensation to stimulate auditory and olfactory senses and reduce energy consumption. The experiment was conducted in an environment test room under the test conditions of temperature $25[^{\circ}C]$, relative humidity 50[RH%], illumination 1,000[lux] and air current speed 0.02[m/sec] by stimulating the auditory senses with a 1/f change in rhythm and the olfactory senses with an aroma scent. The experiment utilized the method of EEG, which evaluates human body's psychological status via tactile means, and the method of the vibra image, which evaluates the learning abilities, HRV and human body's psychological status via non-tactile means. The subjects were selected as eight university students (four males and four females) in their 20s, the type that have high relative ${\alpha}$(8~13[Hz]) activation in occipital lobe, which brings the highest level of mind stability and concentration, who had no difficulty in physical activities. The subjects' posture and physical activity was fixed to 1met - when the subjects are seated and relaxing in a comfortable environment - and their clothes condition was standardized as 0.7clo. As a result, the sentimental and psychological stability and concentration were the highest in the multisensory stimulation of jasmine scent and change rhythm of an a=1.106 sound source. In addition, under this condition, the relative $M{\alpha}$ and relative $M{\beta}$ increased by 70.49[%] and 89.72[%], respectively; the HRT decreased by 39.09[%]; and the fatigue and tension/anxiety decreased by 36.85[%] and 15.54[%], respectively.

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

Reliability and Validity of the Korean Version of the Fear of Daily Activities Questionnaire for Patients with Low Back Pain (허리통증 환자의 한국판 일상동작 공포설문지의 신뢰도와 타당도)

  • Cha, Yong-Jun;Kim, Kyoung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.224-232
    • /
    • 2011
  • The purpose of this study was to test the reliability and validity of the Korean version of the fear of daily activities questionnaire (FDAQ) for low back pain patients. Seventy-three subjects with low back pain were participated in this study. The subjects completed ten standardized self-administered questionnaires that measure fear of specific daily activities. The reliability of the acquired data was determined by the intra-class correlation coefficient (ICC) and the Cronbach's ${\alpha}$ for internal consistency. Constructive validity was analyzed by factor analysis, and concurrent validity was acquired from comparison FDAQ scores to the visual analogue scale (VAS) and Oswestry disability index (ODI) scores. The test-retest reliability of the Korean version of the FDAQ showed good ICC (2,1)= 0.96 (95%CI 0.94.0.98) and Cronbach's alpha value was 0.93. Factor analysis suggested two factors solution consisting of spinal loading and spinal movement/posture, it explained 76.1% of the total variance. The concurrent validity was moderately related with pain and disability. Therefore, the Korean version of the FDAQ is a useful method for measuring the fear of daily activities of patients with low back pain.

A STUDY OF WORKING EFFICIENCY AND FILE DEFORMATION OF GT ROTARY FILE IN CURVED CANALS (GT rotary file을 이용한 만곡 근관형성시 작업 효율 및 file 변형 발생에 관한 연구)

  • 신주희;백승호;배광식;임성삼;윤수한;김병현
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.418-435
    • /
    • 2001
  • Root canal preparation process is of utmost importance in successful treatment of root canal. Also, one of the most important purpose of the root canal preparation is to enlarge the root canal three dimensionally without changing the curvature of the root canal However as the curvature of the root canal increases, there are many difficulties involved in formation of optimum root canal. Therefore in order to solve the above mentioned problems, new developments in methods of root canal preparation and equipments for such purposes were made. Recently, vigorous studies about newly introduced engine-driven nickel-ti-tanium rotary file are conducted. As shown in research results to dates, it is well established that the use of nickel-titanium file is better suited for curved root canal than stainless steel file in maintaining the curvature or root canal and reducing the deformation of root canal. However it is also acknowledged that there are a few discrepancies in research results according to protocol, due to failure to remove variables in experiments. In addition, although it is recommended by the manufacturer that the GT rotary file should maintain a low rotational speed of 150~350rpm and 'light pressure' as light as not to break the lead of a pencil, academic studies about the vertical force which is not yet standardized are not sufficiently explored. Therefore, this research devised and utilized a special research equipment to standardize the appropriate range of vertical force for GT rotary file through experiments by breaking of the lead of a pencil as expressed by the manufacturer and to accurately measure factors involved through repeating and recreating the environment of root canal preparation. Forming nine experimental groups by varying the vertical forces (150g. 220g, 300g) and rpm (150rpm, 250rpm, 350rpm), the effects of changing vertical forces and rpm on working efficiency were measured in terms of time expended in root canal preparation by crown-down method using a transparent resin block with 35 degree curvature and GT rotary file (z-test). The following research using this special research equipment that involved nine experimental groups and varying the vertical force for root canal preparation from 300g which is within the normal vertical force range to 700g and 1000g which fall outside the normal rpm range. The results were as follows : 1. Analysis of the experiment results revealed that the time spent in root canal preparation decreased as the vertical forces and rpm increased (p<0.05). Also, the effects of rpm were greater than those of the vertical forces within the normal vertical force range ($\beta$-weight test). 2. Observation of the deformation of GT rotary file revealed that deformation increases in a direct correlation with the vertical force increase and in a reverse correlation with the rpm decrease. In the case of the vertical forces close to the normal range, the probability of GT rotary file deformation were quite different depending on the rpm changes. In the case of greater vertical forces, the occurrences of deformation of the file were more frequent regardless of the rpm changes. 3. Deformation and breakage of file were also commonly observed in the expended time measurement experiments and GT rotary file deformation experiments in which low speed rpm (150rpm) was used and at the curved portion of the resin block.

  • PDF

SHEAR BOND STRENGTH OF "ONE-BOTTLE ADHESIVE" SYSTEM IN PRIMARY DENTIN. (One-Bottle 상아질 결합제의 유치 상아질에 대한 전단 결합 강도에 관한 연구)

  • Kim, Jong-Bin;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.444-456
    • /
    • 2000
  • To test the shear bond strength of a new "one-bottle adhesive" system to primary dentin two commercially available one-bottle adhesives (Prime & Bond NT, Single bond) and conventional three step system(Scotchbond Multi-Purpose Plus) were included for comparison. And We observe the interfacial morphology by scanning electron microscope. 90 primary molar teeth were embedded in acrylic and buccal and lingual surface were polished to 320 grit to create standardized dentin surface for testing. After bonding of composite resin to sample surfaces according to the manufacturer s direction and 1000 times thermocycling in dwell time 30 second, Shear bond strengths of adhesives to dentin were determined using universal testing machine and analyzed by ANOVA test. Another groups of specimens were treated by hydrochloric acid to secure the resin only and those tags were evaluated under SEM for their length and forms and the morphology of the bonding sites were also observed. The result are as follows. 1. Group I(Prime & Bond NT) showed higher shear bond strength than group iI(Single Bond) and III(Scotchbond Multi Purpose Plus) but no statistically significant difference was founded between groups(p>.05). 2. Relating long resin tags of $70-120{\mu}m$ were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other two group and discontinuous hybrid layer.

  • PDF

The Relationship Between Self-Concept and Self-Care Activities of the Cerebral Palsied Adolescents (뇌성마비 청소년의 자아개념과 자가간호수행의 관계)

  • Hong, Hee-Sook;Lee, Myung-Hwa
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.4 no.1
    • /
    • pp.31-45
    • /
    • 2001
  • The purpose of this study was to investigate the relationship between self-concept and self-care activities of the cerebral palsied adolescents and to gain the baseline data for development of effective rehabilitation nursing intervention program of the cerebral palsied adolescents. The design of this study was a descriptive correlational study. The subjects of the study were 160 cerebral palsied adolescents attending at special schools located in Seoul and Kyonggi and rehabilitation centers located in Seoul, Kyonggi and Kyongnam province. The data was collected from May 20 to July 20, 2000. The instrument used for this study were the self-concept scale(50items 4point scale) and self-care activities scale(29items 4point scale). Self-Concept Scale had developed by Fitt(1965), which was standardized by Chung(1968) and modified by Kim(1984). Self-Care Activities Scale developed by the researcher through out the consulting of expert and pilot study on the basis of ADL check list developed by Kang(1984) and LDSQ-3(Lambeth Disability Screening Questionnair-3) developed by Na et al. (1995). The data was analyzed by the SPSS/PC+program using frequency, percentage, mean, standard deviation, t-test, ANOVA & Scheffe test and Pearson's correlation coefficient. The results of this study were as follows; 1. The mean score of self-concept was $138.55{\pm}17.20$(range: 50-100), which the item mean score was $2.77{\pm}0.34$(range: 1-4). The score of subarea of the self-concept was the highest score in family self ($3.01{\pm}0.54$) and the lowest score in physical self ($2.52{\pm}0.42$). 2. The mean score of self-care activities was $95.25{\pm}21.69$ (range: 29-116), which the item mean score was $3.28{\pm}0.75$ (range: 1-4). The score of subarea of the self-care activities was the highest score in feeding($3.75{\pm}0.59$) and the lowest score in walking($2.64{\pm}1.21$). 3. There were statistically significant difference in the score of self-concept according to the age (F=3.24, P=.04), the grads (F=4.36, P=.01), and types of cerebral palsy (F=2.42, P=.03). 4. There were statistically significant difference in the score of self-care activities according to the age (F=8.29, P=.00), the grads (F=16.05, P=.00), types of living place (F=6.46, P=.00), types of cerebral palsy (F=48.92, P=.00), whether or not receiving a rehabilitation therapy (t=-3.64, P=.00), whether or not receiving a vocational training (t=2.14, P=.03), and whether or not using a device (t=-7.42, P=.00). 5. There was not significant correlation between self-concept and self-care activities (r=.081, P=.311).

  • PDF

The design and FPGA implementation of a general-purpose LDI controller for the portable small-medium sized TFT-LCD (중소형 TFT-LCD용 범용 LDI 제어기의 설계 및 FPGA 구현)

  • Lee, Si-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.4
    • /
    • pp.249-256
    • /
    • 2007
  • AIn this paper, a new desist of LDI controller IC for general purpose is proposed for driving the LDI(LCD Driver Interface) controller in $4{\sim}9$ inches sized portable small-medium TFT-LCD(Thin Film Transistor addressed -Liquid Crystal Display) panel module. The designed LDI controller was verified on the FPGA(Reld Programmable Gate Array) test board, and was made the interactive operation with the commercial TFT-LCD panel successfully. The purpose of design is that it is standardized the LDI controller's operation by one LDI controller for driving all TFT-LCD panel without classifying the panel vendor, and size. The main advantage for new general-purpose LDI controller is the usage for the desist of all panel's SoG(System on a Glass) module because of the design for the standard operation. And in the previous method, it used each LDI controller for every LCD vendor, and panel size, but because a new one can drive all portable small-medium sized panel, it results in reduction of LDI controller supply price, and manufacturing cost of AV(Audio Video) board and panel. In the near future, the development of SoG IC(Integrated Circuit) for manufacturing more excellent functional TFT-LCD panel module is necessary. As a result of this research, the TFT-LCD panel can make more small size, and light weight, and it results in an upturn of domestic company's share in the world market. With the suggested theory in this paper, it expects to be made use of a basic data for developing and manufacturing for the SoG chip of TFT-LCD panel module.

  • PDF

A Convergence study on Education Status, Educational Needs, and Nursing Competence of Regional Trauma Intensive Care Unit Nurses (권역 외상 중환자실 간호사의 교육 현황, 교육 요구 및 간호역량 관련 융합 연구)

  • Kim, Kyoung Mi;Kim, Jong Kyung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.3
    • /
    • pp.321-331
    • /
    • 2020
  • The purpose of this study is to identify the educational status, e,ducation needs and competencies of nurses in the regional trauma intensive care unit. The questionnaires were collected from 123 nurses from 5 hospitals in the regional intensive Care Unit trauma. Data collection consisted of the education importance and needs of the nurses in the intensive Care Unit nurses and the competence of nurses. The analysis was analyzed by descriptive analysis, t-test, and one-way ANOVA, Pearson correlation using the SPSS 21.0 program. The results showed that 78.9% had experience in trauma-intensive care nursing. In the case of the importance of trauma education, 'attitud'e was 3.64, followed by 'knowledge' was 3.52 and 'skill' was 3.47. In the analysis of the educational needs of the trauma service, 'knowledge' was highest at 3.18, 'attitude' was 3.05, and 'skill' was 2.97. The nurses' ethical competence was the highest with 3.62, followed by aesthetic competence was 3.53, personal competence was 3.39, and scientific competence was 3.37. In conclusion, it is necessary to focus on the standardized curriculum and practice-oriented education development of trauma nursing education at the present time and applicable. In addition, it is necessary to seek strategies for enhancing the professionalism and nursing competence of the trauma intensive care unit nurse.