• Title/Summary/Keyword: standardized test

Search Result 1,001, Processing Time 0.031 seconds

A Study on Developing and Validating the Modern Physics Conceptual Diagnostic Survey for Pre-Service Physics Teachers based on the 2015 Revised National Science Curriculum (2015 개정 과학과 교육과정에 기초한 예비 물리교사를 위한 현대물리 개념 진단지 개발 및 타당화 연구)

  • Kim, Wanseon;Kim, Sung-Won
    • Journal of The Korean Association For Science Education
    • /
    • v.40 no.3
    • /
    • pp.253-269
    • /
    • 2020
  • This study aims to develop items to diagnose pre-service physics teachers' understanding of the conceptual knowledge of modern physics, based on the achievement criteria presented in the 2015 revised national science curriculum, and to identify the validity and reliability of the newly developed items. Data were collected from 467 pre-service physics teachers in the Physical Education Department or Science Education Department (Physics Education Major) of 15 universities across the nation. In this study the content validity, substantive validity, the internal structure validity, generalization validity, and the external validity proposed by Messick (1995) were examined by various statistical tests. The results of the MNSQ analysis showed that there was no nonconformity in the 23 items. The internal structure validity was confirmed by the standardized residual variance analysis, which shows that the 22 items was unidimensional. The generalization validity was confirmed by differential item functioning (DIF) analysis about groups lectured or not modern physics/quantum mechanics. In addition, item analysis and test analysis based on classical test theory were performed. The mean item difficulty is 0.66, mean item discrimination is 0.47 and mean point biserial coefficient obtained was 0.41. These results for item parameters satisfied the criteria respectively. The reliability of the internal consistency of the KR-20 is 0.77 and the Ferguson's delta obtained was δ = 0.972. By Rasch model analysis, the item difficulty (item measures) was discussed.

Literature Review for Work-Related Musculoskeletal Disorders based on Theses from 1990 to 2005 (작업 관련성 근골격계 질환 학위 논문 분석 - 1990년부터 2005년까지 -)

  • Rhie, In-Sook;Kim, Soon-Lae
    • Korean Journal of Occupational Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.93-107
    • /
    • 2005
  • Purpose: The purpose of this study is to identify the trends of studies on work-related musculoskeletal disorder and to suggest the direction of future research. Method: 144 research thesis for a degree on work-related musculoskeletal disorder were systematic reviewed and published from Jan. 1990 to Mar. 2005. The analyzed using descriptive statistics, an actual number, percentage. Result: As its result the work-related musculoskeletal disorder research which is announced from domestic the doctorate dissertation at the 2004 year 42 the most many 144 dissertation middle most to be 129 in master degree dissertation was 15 in Ph D degree. Dissertation contents character the contents against the result relation that it analyzes especially and a condition and an obstacle was many most at 84. Research plan in most description investigation research 121 the dissertation field to be the especially public health (hygiene, industry and environment) at this 57 most many research object person distribution manufacturing industry in the research object one dissertation was many most at the 40. The tools which are used in each measurement in the question tool which it uses most the question price of land which uses the condition investigation ticket which it made from the NIOSH and the ANSI most many 33, the hazard which analyzes a work attitude in the tool which it uses the RULA was many most at 14. In the stress test tool social psychological healthy measurement PWI (Psychological Wellbeing Index) the dissertation which uses the Job Strain of the Karasek Model to be many most at 19 PWI (Psychological Wellbeing Index) 7 easy use. Work-related musculoskeletal disorder measurement hazard in physiological index and the machinery and tools which it uses there were 9 researches to use an electromyogram most plentifully. With the effect goes to a work-related musculoskeletal disorder they are 33 where the age is many most from general quality. From healthy act with the relation of smoking the year to be many from 16 dissertations. Work of the corpse an attitude (the attitude which is inappropriate) with 5 and the work market the work burglar is many most at 9, the society-support of 36 where the stress is many psychologically most, the stress and service also the most many duty discretion (authority and autonomy) is 6 at the duty demand boat song 9. The service career to be many is 22 of extraordinarily with relation of service. Conclusion: It is recommended the research which it sees being limited in only domestic thesis for a degree the international comparative study to become accomplished. It comes to think with the fact that it will be necessary to make the protocol which it conforms in the civil official guide the test researches for the protocol or arbitration program which is standardized are necessary. Prevention and the civil official of work relation bones and sinews standing total disease hazard scientific base one program is necessary with base.

  • PDF

Influence of plugger penetration depth on the apical extrusion of root canal sealer in Continuous Wave of Condensation Technique (플러거 삽입깊이가 근관실러의 치근단 정출에 미치는 영향)

  • So Ho-Young;Lee Young-Mi;Kim Kwang-Keun;Kim Ki-Ok;Kim Young-Kyung;Kim Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.5
    • /
    • pp.439-445
    • /
    • 2004
  • The purpose of this study was to evaluate the influence of plugger penetration depth on the apical extrusion of root canal sealer during root canal obturation with Continuous Wave of Condensation Technique. Root canals of forty extracted human teeth were divided into four groups and were prepared up to size 40 of 0.06 taper with ProFile. After drying. canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3. 5, and 7 mm from the apex. Canals of one group were filled with cold lateral compaction technique as a control. Canals were filled with non-standardized master gutta-percha cones and 0.02 mL of Sealapex. Apical extruded sealer was collected in a container and weighed. Data was analyzed with one-way ANOVA and Duncan's Multiple Range Test. 3 and 5 mm penetration depth groups in Continuous Wave of Condensation Technique showed significantly more extrusion of root canal sealer than 7 mm penetration depth group (p < 0.05). However, there was no significant difference between 7 mm depth group in Continuous Wave of Condensation Technique and cold lateral compaction group (p < 0.05). The result of this study demonstrates that deeper plugger penetration depth causes more extrusion of root canal sealer in root canal obturation by Continuous Wave of Condensation Technique. Therefore, special caution is needed when plugger penetration is deeper in the canal in Continuous Wave of Condensation Technique to minimize the amount of sealer extrusion beyond apex.

Mechanical properties of nickel titanium and steel alloys under stress-strain test

  • GRAVINA, Marco A;QUINTAO, Catia A;KOO, Daniel;ELIAS, Carlos N
    • The korean journal of orthodontics
    • /
    • v.33 no.6 s.101
    • /
    • pp.465-474
    • /
    • 2003
  • The great variety of commercial brands of orthodontic wires available on the market, stimulated by the so called superior wires (nickel titanium with shape memory effect and superelastic nickel titanium), makes the professional choice for a suitable and less expensive material difficult. The in vitro study of the mechanical properties of the orthodontic wires acts as an auxiliary tool for the professional. In this paper, a comparative study of mechanical properties was made, using stress strain tests for 4 types of orthodontic wires (conventional stainless steel, multistranded steel, superelastic nickel titanium and thermoactivated nickel titanium) separated into 5 groups. A series of 6 tests were tested for each group of wires. Initially, each group was tested 3 times until the wires broke. Furthermore, 3 more tests for each group were performed, stretching the wires under standardized activation loads, for a reliable comparison of their mechanical properties, during loading and unloading. 1 tests were applied to check differences among the groups. In vitro, the results suggest that regarding the mechanical properties supposedly desirable for physiological teeth movement, such as resilience, elasticity modulus, strength liberated during unloading, and the way that strength is liberated, thermoactivated nickel titanium wires, acting under mouth temperature, seems to be a good choice, fellowed by superelastic nickel titanium, multistranded stainless steel, and conventional stainless sleet. Superelasticity was demonstrated for superelastic nickel titanium wires. When at $37^{\circ}C$, thermoactivated nickel titanium wires showed shape memory effect, showing that temperature is important for enhancing the mechanical properties.

Effects of Controlled-Release Local Delivery Drugs on the Treatment of Adult Periodontitis (국소약물송달제제가 성인형 치주염의 치료에 미치는 효과)

  • Park, Ji-Won;Kwon, Young-Hyuk;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.371-387
    • /
    • 1999
  • The present study was performed to assess and compare the clinical and microbiological effects following local application of 2% minocycline gel or 0.1% chlorhexidine subgingival irrigation to augment scaling and root planing in patients with moderate to advanced chronic adult periodontitis. 32 healthy patients with moderate to advanced chronic adult periodontitis were enrolled in the study. In each patient, the quadrants that had 2 or more teeth with $5{\sim}8mm$ probing pocket depth and radiographic evidence of alveolar bone loss were selected and divided into test side and control side according to the split-mouth design. All patients received standardized oral hygiene instructions at the beginning of the study and all remaining teeth received scaling and root planing until 0 week. The 2% minocycline gel was applied to periodontal pocket at 0, 1, 2, 3 week in the test side. The 0.1% chlorhexidine solution and the normal saline were irrigated subgingivally for about 30 seconds in the positive control side and negative control side respectively. The clinical and microbiological analysis carried out at 0, 4, 8, and 12 weeks . The results of this study were as follows; 1. In saline irrigation group, there was no adjunctive effects in probing pocket depth reduction, sulcular bleeding index and no significant changes in relative proportions of subgingival bacteria. 2. The chlorhexidine irrigation as an adjunct to scaling and root planing results in reduction in the plaque index and sulcular bleeding index, but there was not statistically significant. The relative proportion of spirochetes was significantly reduced, but the proportion of motile rods was no significant reduction. 3. The minocycline gel delivered subgingivally as an adjunct to scaling and root planing provide significant benefit in reducing probing depths and sulcular bleeding index compared to saline and chlorhexidine irrigation groups. 4. The relative proportions of spirochetes and motile rods were significantly reduced and the proportions of cocci and non-motile bacteria were correspondingly increased in the minocycline gel group. In conclusion, minocycline gel delivered subgingivally as an adjunct to scaling and root planing induces clinical and microbial responses more favorable for periodontal health than saline and chlorhexidine subgingival irrigation.

  • PDF

The Relationship between Perceived Stress Scale and Carotid Intima-Media Thickness Using Ultrasonography in University Students (대학생들의 스트레스 지각 정도와 경동맥 내막-중막 두께의 관계 연구)

  • Kim, Dae-Sik;Sung, Hyun-Ho;Lee, Jong-Woo;Cho, Eun-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.308-315
    • /
    • 2017
  • Carotid artery intima-media thickness (CIMT) test is a standardized ultrasound procedure that screens for and monitors atherosclerosis in a safe and non-invasive manner, even in individuals with no symptoms of heart disease. The purpose of this study was to research the relationship between CIMT, as measured by ultrasonography, and the degree of individual perceived stress. There was a total of 168 (male: 46, female: 122) university students in Suwon-si, Gyeonggi-do, Korea, without other diseases. Written informed consent was obtained from all participants. CIMT was measured in the right and left common carotid arteries 1 cm below the bifurcation, and internal carotid artery, using non-invasive high-resolution Medison Accuvix V20 prestige ultrasound equipment and perceived stress, was measured with the 10-item PSS (Perceived Stress Scale) questionnaire. This study indicates that PSS may be appropriate to estimate perceived stress levels and weight. Failure to control stress anxiety could lead to weight and CIMT soaring to dangerous levels, resulting in a myocardial infarction or cerebrovascular accident. There was a statistically significant difference between left CIMT (p<0.05) and weight (p<0.05) according to each stress classification. The results of this study suggest that the weight measurement is influenced in part by one's generalized stress levels. Future continuous studies should be conducted to test the influences of perceived stress and generalized anxiety on CIMT when these are many continuous variables.

Clinical Significance of the Degree of Fatty Liver Diagnosed by Ultrasonography (초음파검사로 진단된 지방간 정도의 임상적 의의)

  • Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.135-140
    • /
    • 2008
  • Purpose: Fatty liver is one of the most commonly found disease by abdominal ultrasonography. The status of fatty liver is classified into mild, moderate and severe degrees. The study was conducted to investigate the clinical significance of fatty liver using ultrasonography. Materials and method: Test set consisted of 2,185 patients who visited D healthcare center in Daejeon to receive an abdominal ultrasonic test from January to December 2007. Out of the 2185 patients, 524 patients was diagnosed as fatty liver (290 male and 234 female patients). They were divided into three groups, group I for mild degree. II for moderate degree, and III for severe degree, depending on the echo of liver parenchyma, the sound attenuation, and the visibility of intrahepatic blood vessels and diaphragm. Then the correlation of obesity indices, liver function tests and metabolic syndrome was analyzed for males and females separately. Results : As for the degree of fatty liver, 350 cases (66.8%) were classified as group I, 153 cases (29.2%) as group II, and 21 cases (4.1%) as group III. In addition, severe degree of fatty liver was more frequently found in males than in females. The mean ages of three groups for males were 46.1, 44.5, and 39.1, and those for females were 48.8, 50.2, 52.4, respectively. Males with lower mean ages have severely of fatty liver for both males and females. Conclusion: The results in this study show that the classification into three degrees of fatty liver in ultrasonography practice is helpful to treat and observe the progress of fatty liver. In addition, careful examination is required to measure the severity of fatty liver as well as detection of it. A standardized method to classify the degree of fatty liver is also needed for more objective measurement.

  • PDF

Study on Utilization Drones in Domestic Logistics Service in Korea (한국내 물류서비스에 드론 활용을 위한 연구)

  • Kang, Ki-Seog;Jeon, In-Oh
    • Journal of Distribution Science
    • /
    • v.14 no.5
    • /
    • pp.51-57
    • /
    • 2016
  • Purpose - In the year of 2015 and 2016, one of the items that got attention in CES was a drone. It has been 100 years since a drone emerged, but most were used for military purposes. As its use became diverse as of 2010, it got attention of the general public. In Korea, it was in 2011 that a drone was known to the public through an aerial video shooting for television program. This study tried to come up with suggestions by comparing domestic with overseas cases, and tried to consider the related technologies and systems with applying the role of drones in logistics service. Research design, data, and methodology - The overseas cases were regarded as drone's logistical purpose. The Prime Air service by US Amazon is still not commercialized and under pre-testing due to Federal Aviation Regulations, although it started in 2013. In Germany, DHL succeeded in delivering service testing which is called Parcelcopter, but it is not commercialized yet. Other than these, there are more attempts to prepare logistics service in China with Taobao, in France with Geopost's test, and in Africa. In Korea, CJ Korea Express tested delivery with a self-developed drone Results - In order to study for utilizing drones for logistics as the prerequisites, some overseas and domestic cases, which are currently considered, were reviewed. Also, the technologies and institutional requirements to commercialize drones for logistical purpose were reviewed. The reasons for using drones in logistics is to ensure the price competitiveness by reducing cost. The empirical test also will be needed because drone pilot areas are designated by ministry of land, infrastructure and transport. Conclusions - In order to utilize drones in logistics and foster the industry, this study would like to suggest the followings. First of all, size of drones for logistics needs to be fixed and their operating system should be standardized. Centralized investment resources are needed through standardization to ensure the market occupancy. Secondly, it is necessary to get the converged businesses that do research, develop and commercialize drones with the investment of private sector. Example can be found in Korea aerospace Industries. We can respond to the rapid growth of the market with intensive investing by integrating the private sector investment. Thirdly, institutional arrangements are needed to be established quickly. In the case of high-technologies like drones, institutional support often does not follow the rapid development of the technology. The problems can be found in securing drones-only airspace, creating drone-specialized pilot's license, matters related to remote controller and complementary regulations for drones in Aviation Act. If these regulations are not prepared or complemented at the right timing, technologies cannot be commercialized even though the development is completed. Fourthly, there is a need to secure the transparency regarding possible privacy and personal information protection problem while operating drones. Finally, in order to foster this new industry, government should focus on supporting R&D more in the long term than short term outcomes.

Real-Time Implementation of the G.729.1 Using ARM926EJ-S Processor Core (ARM926EJ-S 프로세서 코어를 이용한 G.729.1의 실시간 구현)

  • So, Woon-Seob;Kim, Dae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.8C
    • /
    • pp.575-582
    • /
    • 2008
  • In this paper we described the process and the results of real-time implementation of G.729.1 wideband speech codec which is standardized in SG15 of ITU-T. To apply the codec on ARM926EJ-S(R) processor core. we transformed some parts of the codec C program including basic operations and arithmetic functions into assembly language to operate the codec in real-time. G.729.1 is the standard wideband speech codec of ITU-T having variable bit rates of $8{\sim}32kbps$ and inputs quantized 16 bits PCM signal per sample at the rate of 8kHz or 16kHz sampling. This codec is interoperable with the G.729 and G.729A and the bandwidth extended wideband($50{\sim}7,000Hz$) version of existing narrowband($300{\sim}3,400Hz$) codec to enhance voice quality. The implemented G.729.1 wideband speech codec has the complexity of 31.2 MCPS for encoder and 22.8 MCPS for decoder and the execution time of the codec takes 11.5ms total on the target with 6.75ms and 4.76ms respectively. Also this codec was tested bit by bit exactly against all set of test vectors provided by ITU-T and passed all the test vectors. Besides the codec operated well on the Internet phone in real-time.

The Effect of Schizotypal Personality Trait on the Ability of Facial Affect Identification in Healthy Person (정신분열형 인격 성향이 정상인의 안면 표정 인식 능력에 미치는 영향)

  • Yi, Hyeon-Lyung;Kim, Seung-Yeon;Choo, Jung-Suk;Lee, Kyoung-Uk;Chae, Jeong-Ho;Park, Young Min;Kim, Hyun;Lee, Kang Joon;Chung, Young-Cho;Lee, Seung-Hwan
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.4
    • /
    • pp.297-302
    • /
    • 2008
  • Objectives : The purpose of this study is to investigate whether the ability of facial affect perception is associated with schizotypal personality traits in healthy normal controls. Methods : 241 normal subjects were recruited in this study. The age range of all subjects was from 19 to 63 years. The schizotypal personality questionnaire(SPQ) and facial affect identification test(FAIT), which were developed and standardized in Korea, were applied. Subjects from high 1 standard deviation(H group, N=40) and low 1 standard deviation(L group, N=26) on SPQ score were compared. Results : We found that the H group showed significantly reduced ability on the correctness of sadness and neutral compared with the L group. But, no significant association between SPQ and intensity or reaction point was observed in all subjects. Conclusion : This study suggests the individuals with high schizotypal personality trait have impairments on the facial affect identification. Also, these findings may provide the reasonable explanation of social cognition deficit of schizotypal personality disorder.

  • PDF