• Title/Summary/Keyword: standard time

Search Result 8,229, Processing Time 0.035 seconds

A Study on the Manabe Standard Form Using the Evolutionary Strategy (진화전략을 이용한 Manabe 표준형에 관한 연구)

  • 강환일;정요원
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2001
  • The step response of the Manabe standard form[2] has little overshoot and show almost same waveforms regardless of the order of the characteristic polynomials. In some situations it is difficult to control the rise time and settling time simultaneously of the step response of the Manabe standard form To control its rise time and settling time efficiently, We develop the Manabe standard form: We try to find out the SRFS(Slow Rise time & Fast Setting time) form which has the slower rise time and faster settling time than those fo the Manabe standard form. We also consider the other three forms: FRSS(Fast Rise time & Slow Settling time), SRFS(Slow Rise time & Fast Settling time) and SRSS(Slow Rise time & Slow Settling time) forms. In this paper, by using the evolutionary strategy, we obtain all the coefficient of the four forms we mention above. Finally, we design a controller for a given plant so that the overall system has the performance that the rise time is faster, the settling time is faster than those of the Manabe standard form.

  • PDF

A Study on the Generalization of the Manabe Standard Forms with the Genetic Algorithm

  • Kang, Hwan-Il;Jung, Yo-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.116-120
    • /
    • 1999
  • The step response of the Manabe standard form[1]has little overshoot and shows almost same waveforms regardless of the order of the characteristic polynomials. In some situations it is difficult to control the rise time and settling time simultaneously of the step response of the Manabe standard form. To control its rise time and settling time efficiently, we develop the generalization of the Manabe standard form: we try to find out the SRFS(Slow Rise time & Fast Settling time) form which has the slower rise time and faster settling time than those of the Manabe standard form. we also consider the other three forms: FRSS(Fast Rise time & Slow Settling time), SRFS(Slow Rise time & Fast Settling time) and SRSS(Slow Rise time & Slow Settling time) forms. In this paper, by using the genetic algorithm, we obtain all the coefficient of the four forms we mention above. Finally, we design a controller for a given plant so that the overall system has the performance that the rise time is faster, the settling time is slower than those of the Manabe standard form.

  • PDF

Establishment of Work and Time Standards in Machining rations including NC Machines (NC기계들이 포함된 기계공작공정에서의 작업연구)

  • 유인선;오근태
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.33
    • /
    • pp.11-27
    • /
    • 1995
  • This study sets a goal of establishing work standard and standard time in a machine tool process consisted of high-priced NC machine tools. Firstly, the theories of work standard and standard time in the field of NC machine tools are studies. Secondly, the theories are actually applied to a manufacturing company; work standard sheets are developed and applied to a machining center haying low operation rate, and then the increase in productivity is compared. Finally, problems to be studied later in relation to work standard and standard time are presented.

  • PDF

Development of A Standard Time Data for Shirt Sewing Operations (셔츠 봉제 작업을 위한 표준시간자료의 개발)

  • Kim, Dong-Won;Kang, Mi-Young
    • IE interfaces
    • /
    • v.6 no.2
    • /
    • pp.91-101
    • /
    • 1993
  • Developed in this paper is a standard time data for shirt sewing operations in the apparel-making industry. Since this data is made of formula developed for each unit operation and includes the formula for the machine time calculation, users could use it for obtaining the normal or standard time without any special efforts. In addition, this data handles the variations due to the design changes of a shirt through the parameters in the formula. compared with the MTM-1. The standard time data developed is shown to be easier and faster in determining the standard time with acceptable accuracy.

  • PDF

면삭밀링의 합리적인 표준시간 계산방법에 관한 연구

  • 박규생;김준안;김선태;김병현;정성련
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.250-255
    • /
    • 1992
  • This paper discusses how to develop a standard time for face cutting. The discussion focusses especially on the useful experert and law data for automated generate standard time purposes. Make standard time is a means to realize the process planning. Also process planning is a process which expresses design. In past times, a process planning was done using only experience of expert. But nowadays many people try to make automated process planning. This paper discusses standard time of the face cutting, but except making process sequence. In order to make standard time, some rules have to be generated and some industrial data found out. So we can calulate standard time in die. This is to easer and to correct calulate standard time. Using some rules that are application oriented to every parts of die.

Determining Standard Times of Assembly Products using A Modified BOM (수정 BOM 을 이용한 조립제품의 표준시간 산출)

  • Um, Kwang-Yong;Lee, Moon-Kyu
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.103-114
    • /
    • 1998
  • This paper suggests a computer software system which generates standard times for assembly products. The system called "computer aided logical system for standard times(CALS4ST)" incorporates a modified bill of materials, BOM4ST(BOM for standard time) to deal with auxiliary operations which are not directly related to parts and assemblies listed in the standard BOM. Typical examples of the operations include inspection, adjustment, and repairing works to be done before or after assembly operations. Once standard time data bases for both the part assembly operations and the auxiliary operations are set up, the system relates the BOM4ST to the standard time data bases so as to calculate the standard time for a assembly part concerned. According to the structure of parts and auxiliary operations in the BOM4ST, their standard times stored in the data bases are to be sequentially added up considering the specified assembly-operation characteristics. To illustrate the feasibility of the system, the case study of L company is provided.

  • PDF

TCE Exposure Assessment of Cleaning Workers (세척공정의 트리클로로에틸렌 TWA 및 STEL 평가 사례)

  • Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.3-5
    • /
    • 2023
  • Objective: This study introduces exposure concentrations of time-weighted average standard (TWA) evaluation and short-time exposure standard (STEL) evaluation for trichloroethylene in the cleaning process. Methods: Trichloroethylene measurement was conducted according to the KOSHA Guide (A-24-2019) method. It was carried out twice. Results: As a result of the first measurement, TWA concentration exceeded 4 times the exposure standard and STEL concentration exceeded 16 times, but the inaccuracy and breakthrough of the collection time could not be considered, so the second measurement was conducted. The second measurement result was lower than the first measurement result, but exceeded the exposure standards (TWA, STEL). Conclusions: We were able to confirm that the exposure level of workers in the cleaning process using trichloroethylene exceeded the exposure standard. And it is also considered necessary to grasp the approximate concentration using a detector tube in the preliminary survey.

Measurement and Analysis of the Standard Nursing Practice Times of the ICU Nursing Activities (중환자실 간호행위에 대한 간호소요시간 측정 및 분석)

  • Yoo, Cheong-Suk;Kim, Keum-Soon
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.2
    • /
    • pp.56-67
    • /
    • 2009
  • Purpose: This study was done to suggest the standard ICU nursing procedure and standard ICU nursing practice time carried out according to the standard ICU nursing procedure. Methods: Through the literature review, 35 standard ICU nursing activities were selected and classified under 6 categories. Standard nursing procedures were described by research team and 4 clinical practice experts. Content validity of descripted nursing procedure was performed by 6 clinical practice experts. After that standard ICU nursing procedures were identified, standard nursing practice times were checked through 1:1 observation. Results: 35 ICU nursing activities were identified and categorized into 6 domains of activities. Also, their standard nursing procedures were identified, and finally 33 standard nursing practice times were measured and analyzed. The result of the measurement, 1 ICU nursing activity was spent above 30 minutes, 3 activities done within 10-20 minutes, 4 activities done within 5-10 minutes, and 25 activities were spent below 5 minutes. Conclusion: Through this study, 35 standard ICU nursing procedures were described and 33 standard ICU nursing practice times which carried out according to standard ICU nursing procedures were checked. The result can be as fundamental data for the study of nursing activity time in the ICU.

  • PDF

The Design and Implementation of C Standard Library for RTOS Q+ (실시간 운영체계 Q+를 위한 C 표준 라이브러리 설계 및 구현)

  • Kim, Do-Hyeong;Park, Seung-Min
    • The KIPS Transactions:PartA
    • /
    • v.8A no.1
    • /
    • pp.1-8
    • /
    • 2001
  • This paper describes the design and implementation of C standard library for real-time operating system Q+, that is being developed for the internet appliance. The C library in the real-time operating system should be defined according to the standard interface and support the concurrent execution of threads. The implemented C standard library is reentrant and follows POSIX.l standard interface. And, the C standard library functions, which are adequate to the Q+ application and commonly provided by commercial real-time operating systems, are selected among POSIX.l standard functions. The C standard library is implemented on the Q+ kernel and D-TV set-top box according to the implementation sequence, which is determined by analyzing the relation of function calls.

  • PDF

Establishment of Standard Time for Stranding Process of A Cable Company in Small Quantity Batch Production System (전선제조 연합공정의 표준시간 설정 - 다품종소량생산시스템을 중심으로 -)

  • Lee, Kyoung-Jong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.3
    • /
    • pp.95-102
    • /
    • 2012
  • It is not easy to establish the correct standard time and standard manhour in a process of small quantity batch production system, especially in a case of irregular quantity of production. Therefore, how to establish rational standard time about manufacturing process of a power cable company which is representative business for small quantity batch production system will be suggested in this paper. Furthermore, how to establish standard manhour which can be used for effective control of labor productivity will also be presented.