• 제목/요약/키워드: standard set

검색결과 2,539건 처리시간 0.03초

MITIGATION AND REMISSION OF CONTRACTOR'S DEFECTS LIABILITY IN KOREAN CONSTRUCTION CONTRACTS

  • Jong-Gwang Lee ;Yong-Su Kim
    • 국제학술발표논문집
    • /
    • The 1th International Conference on Construction Engineering and Project Management
    • /
    • pp.447-451
    • /
    • 2005
  • The purpose of this study is to improve regulations such as law and standard contract forms related to defects liability in Korea. Defects liability has been one of the major causes of construction contract disputes in Korea in recent years. It is important to avoid or resolve disputes regarding defects liability through regulations containing clear criteria and to specify the standard regarding the mitigation and remission of the contractor's defects liability. This study was carried out through document research and analysis of judicial precedents. The following are the courses of improvement regarding the mitigation and remission of defects liability in Korea. First, laws and standard contract forms must contain more detailed clauses regarding exemption of a contractor's defects liability, which clearly set out the scope of the defects liability of the contractor. Second, the current system for defects liability favors the owner rather than the contractor - it is necessary to change the defects liability system in order to give the owner and the contractor an equal standing. Third, strict liability is taken on by the contractor even when the term of guarantee for defects lasts longer than the legally set period of liability for defects. Hence, it is necessary to improve the system by alleviating the liability of the contractor through applying negligence liability as opposed to strict liability during the term of guarantee.

  • PDF

THE FORCING NONSPLIT DOMINATION NUMBER OF A GRAPH

  • John, J.;Raj, Malchijah
    • Korean Journal of Mathematics
    • /
    • 제29권1호
    • /
    • pp.1-12
    • /
    • 2021
  • A dominating set S of a graph G is said to be nonsplit dominating set if the subgraph ⟨V - S⟩ is connected. The minimum cardinality of a nonsplit dominating set is called the nonsplit domination number and is denoted by ��ns(G). For a minimum nonsplit dominating set S of G, a set T ⊆ S is called a forcing subset for S if S is the unique ��ns-set containing T. A forcing subset for S of minimum cardinality is a minimum forcing subset of S. The forcing nonsplit domination number of S, denoted by f��ns(S), is the cardinality of a minimum forcing subset of S. The forcing nonsplit domination number of G, denoted by f��ns(G) is defined by f��ns(G) = min{f��ns(S)}, where the minimum is taken over all ��ns-sets S in G. The forcing nonsplit domination number of certain standard graphs are determined. It is shown that, for every pair of positive integers a and b with 0 ≤ a ≤ b and b ≥ 1, there exists a connected graph G such that f��ns(G) = a and ��ns(G) = b. It is shown that, for every integer a ≥ 0, there exists a connected graph G with f��(G) = f��ns(G) = a, where f��(G) is the forcing domination number of the graph. Also, it is shown that, for every pair a, b of integers with a ≥ 0 and b ≥ 0 there exists a connected graph G such that f��(G) = a and f��ns(G) = b.

CMOS 표준 Cell Library를 이용하는 수평 트랙 배선 시스템 (A channel Routing System using CMOS Standard Cell Library)

  • 정태성;경종민
    • 대한전자공학회논문지
    • /
    • 제22권1호
    • /
    • pp.68-74
    • /
    • 1985
  • 이 논문에서는 standard cell의 layout을 위한 doglegging을 하지 않는 channel 배선 시스템에 대하여 서술할 것이다. 이 시스템은 주어진 net list specification을 만족시키기 위하여, 각각 standard cell 의 직선 배열 결합인 두 row 사이의 구평 track에서 이층의 최종 배선 패턴을 만들어 준다. 이 논문에서 사용한 CMOS cell library는 9개의 기본 cell을 가지고 있으며, Mead-Cogway 방식에서의 A-2micron을 사용하여 CIF(Caltech Intermediate From) 형태로 표현되었다. Component library에는 각 cell 내의 pin들의 이름. 위치 및 layer type 등의 입출력 port 특성이 저장되어서, CROUT라는 channel routing program에서 입력 자료로 사용된다. 또 다른 program NETPLOT은 routing 결과를 개략적으로 도시하여 주며, NETCIF에서는 최종의 자세한 layout을 CIF file로 만들어 주고 있다. 기본 cell을 이온하여 set/reset이 있는 dynamic Raster-slave형 D flip-flop에 대한 channel routing의 경우 VAX l1/780 에서 4초의 CPU 시간이 소요되었다.

  • PDF

ESR 자동분석기를 이용한 내부정도관리방법 (The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate)

  • 조영국;심현설;송운흥;박규은
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

1916년 <조선총독부건축표준>의 제정 배경과 계획적 적용 (The Context of Enactment and the Application to the Design of in 1916)

  • 주상훈
    • 건축역사연구
    • /
    • 제28권6호
    • /
    • pp.67-76
    • /
    • 2019
  • The purpose of this study is to identify the context of enactment and the application to the design of in 1916. The characteristics of the composition are as follows; First, One-third are general rules of common application, Second, regulations related to cold resistance are set up separately, last, each of the 21 articles was equally divided for schools, hospitals and prisons. The standard reflect the times of the mid-1910s. The Trend of using of the Western Building System in the 1910s, The need for building construction against cold weather, and Actual conditions of renovation, extension and new plans by facility. Furthermore, the fact that various regulations concerning standard design were enacted and used in various Japanese institutions around the 1910s may have influenced the establishment of the standard. Meanwhile, after checking the status of the reflection of the standard on the planning drawings of the government facilities around 1916, it was also found that the plan was carried out in compliance with the provisions of the standard, and that the items already applied before the enactment had been organized into architectural standards.

표준원가 분석을 통한 재활용 기준비용 재산정에 관한 연구 (A Study on Re-calculation of Recycling Standard Cost through the Analysis on Standard Cost)

  • 이희남;최윤정
    • 대한안전경영과학회지
    • /
    • 제13권1호
    • /
    • pp.189-193
    • /
    • 2011
  • The current standard cost for recycling applied under the Extended Producer Responsibility(EPR) institution, is not coping with continuously increased number of obligatory subject items as well as a variety of variable cost changing factors regarding the recycling treatment cost caused by price fluctuation such as increased material and labor cost entirely across the society; changes in recycling treatment process following the developing technologies; and changes in the required work forces and equipments followed by the trends of automated facilities. Despite such various cost fluctuation factors, the current EPR is not coping with the trends, making the re-calculation process difficult, which causes differences between the real treatment cost for recycling. In this study, the analysis was made on main factors affecting on the related cost and the related price changing index was calculated, by conducting the influence evaluation on the standard cost factors of the current standard cost for recycling. Through theses results, more objective standard will be set for the re-calculation of standard cost for recycling to greatly contribute to setting up the midterm and long-term strategies in the future towards efficient institution.

공공기관 데이터세트 식별과 평가 절차 연구 국가철도공단 전자조달시스템 사례를 중심으로 (Study on Public Institution Dataset Identification and Evaluation Process : Focusing on the Case of KR Electronic Procurement System)

  • 황진현;백영미;임진희
    • 기록학연구
    • /
    • 제70호
    • /
    • pp.41-83
    • /
    • 2021
  • 공공기록물법 시행령 개정 이후 기록관에서는 데이터세트 기록 관리를 위한 관리기준표를 작성하고 이에 대한 관리와 통제를 수행하게 되었다. 이에 본 연구에서는 기록관의 체계적 데이터세트 기록 관리를 위한 데이터세트 기록 식별 절차와 평가 지표를 개발하였다. 이를 적용하여 국가철도공단의 KR전자조달시스템의 8개 데이터세트 기록 식별 후 관리기준표를 작성하였고, 평가지표에 따라 평가를 진행, 보존기간과 이관 및 수집 여부를 책정하였다. 데이터세트 기록의 관리 절차에 대한 구체적 사례가 부족한 시점에, 이 사례연구가 기록관에 실무적 도움이 되기를 바란다.

국부 확률을 이용한 데이터 분류에 관한 연구 (A Study on Data Clustering Method Using Local Probability)

  • 손창호;최원호;이재국
    • 제어로봇시스템학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-51
    • /
    • 2007
  • In this paper, we propose a new data clustering method using local probability and hypothesis theory. To cluster the test data set we analyze the local area of the test data set using local probability distribution and decide the candidate class of the data set using mean standard deviation and variance etc. To decide each class of the test data, statistical hypothesis theory is applied to the decided candidate class of the test data set. For evaluating, the proposed classification method is compared to the conventional fuzzy c-mean method, k-means algorithm and Discriminator analysis algorithm. The simulation results show more accuracy than results of fuzzy c-mean method, k-means algorithm and Discriminator analysis algorithm.

전자봉투를 제거한 ASET(Advanced SET) 프로토콜 (ASET(Advanced SET) Protocol without Digital Envelope)

  • 양승해;신대원;이병관
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2003년도 춘계학술발표논문집 (하)
    • /
    • pp.1913-1916
    • /
    • 2003
  • 전자상거래 일반적인 구조인 SET(Secure Electronic Transaction)프로토콜은 비밀키 알고리즘의 DES(Data Encryption Standard), 공개키 알고리즘의 RSA(Rivest, Shamir, Adleman), 메시지 다이제스트의 SHA-1를 사용하고 있다. 본 논문에서는 비밀키 알고리즘의 DES를 이용하여 수신측에 전송하는 과정을 3BC알고리즘으로 대체함으로서 생략하였고, 공개키 알고리즘의 요소를 ECC(Elliptic Curve Cryptosystem)알고리즘을 사용하였다. 또한 전자서명을 위한 방법은 Double Signature를 사용하여 SET프로토콜에서 DES의 전송을 위한 전자봉투를 삭제한 결과 수행시간의 단축과 보안의 강도를 강화시켰다.

  • PDF

Analysis of Viscous Free Surface Flow around a Ship by a Level-set Method

  • Park, Il-Ryong;Chun, Ho-Hwan
    • Journal of Ship and Ocean Technology
    • /
    • 제6권2호
    • /
    • pp.37-50
    • /
    • 2002
  • In the present numerical simulation of viscous free surface flow around a ship, two-fluids in-compressible Reynolds-averaged Navier-Stokes equations with the standard $\textsc{k}-\varepsilon$turbulence model are discretized on a regular grid by using a finite volume method. A local level-set method is introduced for capturing the free surface movement and the influence of the viscous layer and dynamic boundary condition of the free surface are implicitly considered. Partial differential equations in the level-set method are discretized with second order ENO scheme and explicit Euler scheme in the space and time integration, respectively. The computational results for the Series-60 model with $C_B=0.6$ show a good agreement with the experimental data, but more validation studies for commercial complicated hull forms are necessary.