• 제목/요약/키워드: standard sample

검색결과 2,195건 처리시간 0.039초

Development of Multi-sample Loading Device for TEM Characterization of Hydroxyapatite Nanopowder

  • Lee, Jong-Moon;Kim, Jung-Kyun;Jeong, Jong-Man;Kim, Jin-Gyu;Lee, Eunji;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.788-792
    • /
    • 2013
  • A shortcoming of using transmission electron microscopy (TEM) for structural analysis via electron diffraction is the relatively large error of the measurements as compared to X-ray diffraction. To reduce these errors, various internal standard methods from earlier studies have been widely used. We developed a new device to facilitate the application of internal standard methods in preparation of TEM grids used for nanopowder analysis. Through the application of a partial mask on the TEM grid, both the internal standards and the research materials can be loaded on the same grid. Through this process, we conducted a TEM analysis that compared synthetic hydroxyapatite (HAp) nanopowder to bone apatite from a bovine femur. We determined that the accuracy of the d-spacing measurements of the HAp and bone powders could be improved to better than 1% after statistical treatments of the experimental data. By applying a quarter mask, we loaded four different nanoparticles on a single TEM grid, with one section designated for the internal standard.

계량형 관리도의 관리규격 계산에 사용되는 여러 계수값 사이의 관계 (Relationships among various factors used in calculating control limits of control chart for variable data)

  • 박성균;김영균
    • 품질경영학회지
    • /
    • 제30권4호
    • /
    • pp.86-93
    • /
    • 2002
  • There are many different factors used in calculating control limits of control chart for variable data. Specially these factors are divided into two groups such as "no given standard" and "given standard"(namely, for analysis and management), but many kind of factors give rise to confusion. Therefore, It is necessary to manifest relationships among factors for easy application regardless of subgroup size. Many SQC textbooks show us plainly these factors, but do not have enough for adequate explanation of relationships among factors. Besides, notation of these factors of SQC textbook isn't coincide with another one, so necessity to the coincidence for the notation of the factors is highlighted during my work recently. In this study, the close examination about relationships among various factors (A-A3, B3-B6, D1-D4, C4, d2, d3 etc) was carried out. Spread sheet results are presented for getting factors according to subgroup size, by grouping as the case of "no given standard" and "given standard". How are these factors to be applied in statistical package (ex, Minitab) have been analyzed using a series of sample data. analyzed using a series of sample data.

폴리올레핀계 분리막의 친수화 처리방법에 따른 Ni-MH 2차 전지의 전기화학적 특성연구 (Effect of the Hydrophilic Treatment of Polyolefin Separator on the Electrochemical Characteristics for Ni-MH Secondary Battery)

  • 송리규;이윤성
    • Korean Chemical Engineering Research
    • /
    • 제51권2호
    • /
    • pp.263-266
    • /
    • 2013
  • 본 연구에서는 친수화 처리된 격리막을 이용한 니켈수소전지의 전기화학적 특성을 연구하였다. 수계 전해액을 사용하는 니켈수소전지로의 적용을 위해 폴리올레핀계 분리막을 친수화 처리하였다. 친수화 미처리품은 방전성능, 용량보존성, 내구성 등의 전기화학적 성능에서 KS 규격기준에 미달되었지만 친수화 처리품은 KS 규격기준을 모두 만족시켰다. 친수화 처리품을 적용한 모든 시료는 유사한 전지성능을 보여주었다. 그 중 술폰화 처리 시료의 경우 용량 보존율(>88%) 측면에서 가장 우수한 특성을 보였으며, 불소화 처리시료는 내구성 측면에서 가장 우수한 성능을 보였는데, 이는 KS 규격기준(500회)과 비교할 때 약 3배 정도(1480회)의 우수한 성능을 유지함을 확인하였다.

유통중인 건강기능식품의 감마-리놀렌산 및 오메가-3 지방산 함량 모니터링 (Monitoring of compositions of gamma-linolenic and omega-3 fatty acids in some functional foods consumed in market)

  • 김대경;신정아;이기택
    • 농업과학연구
    • /
    • 제38권2호
    • /
    • pp.277-284
    • /
    • 2011
  • The compositions of health functional food products (HFFP; 18 products) containing gamma linolenic acid (GLA; $C_{18:3}$, n-6) and omega-3 fatty acids (EPA and DHA) were investigated. The contents of index components (especially, GLA and omega-3) in HFFPs were monitored by GC-FID analysis. Among the GLA products (sample No. 1~8), the content of GLA in most samples (except sample No.6) ranged from 8.04 to 9.98 g/100 g. These results were suitable for the reference standard (more 7.0 g/100 g) of HFF. In the omega-3 products (sample No. 10 and 15) derived from harp seal oil (HSO), the total contents of EPA and DHA were 14.21-15.98 g/100 g, respectively. These values were suitable for the reference standard (more 12.0 g/100 g) of HFF. Besides, among the omega-3 products (sample No.9, 11~14, 16~18) derived from fish oil, the total content of EPA and DHA ranged from 24.11 to 31.20 g/100 g. These results were suitable for the reference standard (more 18.0 g/100 g) of HFF. In the result of TLC analysis, the HFFPs of 18 were mainly composed of triacylglycerols (TAGs). The content of trans fatty acid in 18 HFFPs was detected in less than 0.30 g/100 g. For the detection of trans fatty acid, $^1H$-NMR (600 MHz) can be used because chemical shift of trans fatty acid was observed at 5.3 ppm in this study.

An Overview of Bootstrapping Method Applicable to Survey Researches in Rehabilitation Science

  • Choi, Bong-sam
    • 한국전문물리치료학회지
    • /
    • 제23권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Parametric statistical procedures are typically conducted under the condition in which a sample distribution is statistically identical with its population. In reality, investigators use inferential statistics to estimate parameters based on the sample drawn because population distributions are unknown. The uncertainty of limited data from the sample such as lack of sample size may be a challenge in most rehabilitation studies. Objects: The purpose of this study is to review the bootstrapping method to overcome shortcomings of limited sample size in rehabilitation studies. Methods: Articles were reviewed. Results: Bootstrapping method is a statistical procedure that permits the iterative re-sampling with replacement from a sample when the population distribution is unknown. This statistical procedure is to enhance the representativeness of the population being studied and to determine estimates of the parameters when sample size are too limited to generalize the study outcome to target population. The bootstrapping method would overcome limitations such as type II error resulting from small sample sizes. An application on a typical data of a study represented how to deal with challenges of estimating a parameter from small sample size and enhance the uncertainty with optimal confidence intervals and levels. Conclusion: Bootstrapping method may be an effective statistical procedure reducing the standard error of population parameters under the condition requiring both acceptable confidence intervals and confidence level (i.e., p=.05).

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

표본크기 결정을 위한 IQR의 활용방법 (Using the Sample IQR for Calculating Sample Size)

  • 홍종선;김현태;윤상호;정민정
    • 응용통계연구
    • /
    • 제16권1호
    • /
    • pp.181-193
    • /
    • 2003
  • 표본크기를 결정할 때 모표준편차 $\sigma$의 추정량으로 표본표준편차를 구할 수 없는 경우 범위(R)또는 사분위간 범위(IQR)를 이용하여 $\sigma$의 추정량으로 사용할 수 있다 R과 IQR의 함수로 나타난 추정값은 최소한 95% 이상의 확률로 $\sigma$보다 크거나 같아야 과소 추정됨을 피할 수 있다. 다양한 확률분포로부터 추출된 여러 표본의 범위와 사분위간 범위에 대하여 Browne(2001)이 연구한 추정량 R/4과 본 연구에서 제시한 추정량 IQR이 $\sigma$이상일 확률에 대하여 비교 분석을 하였다. 그리고 표본의 범위와 사분위간 범위를 상수로 나누었을 때 $\sigma$이상일 확률을 가질 수 있는 대안적 인 분모를 각각 구하여 비교 연구하였다.

이중 성향점수 보정 방법을 이용한 처리효과 추정치의 표준오차 추정: 붓스트랩의 적용 (Bootstrap estimation of the standard error of treatment effect with double propensity score adjustment)

  • 임소정;정인경
    • 응용통계연구
    • /
    • 제30권3호
    • /
    • pp.453-462
    • /
    • 2017
  • 성향점수 매칭은 관찰연구에서 처리효과 추정 시 혼란변수에 의한 편의를 줄이기 위해 자주 사용되는 방법이다. 매칭을 위해 처리군에 대응되는 대조군 선정 시 처리군의 일부가 탈락되는 경우가 발생할 수 있는데, 이로 인해 편의가 발생할 수 있다. 최근, Austin (2017)의 연구에서 이중 성향점수 보정(double propensity score adjustment)방법을 사용하는 것이 이에 대한 해결책이 될 수 있음을 제시하였다. 하지만, 처리효과 추정치의 표준오차는 이론적 추정치가 제시되지 않아 추정에 어려움이 있다. 본 연구에서는 이중 성향점수 보정 방법을 이용한 처리효과 추정치의 표준오차 추정을 위하여 두 가지 붓스트랩 방법을 제안한다. 첫 번째는 원 자료에서 성향점수 매칭 후 매칭 된 표본에서 붓스트랩 표본을 얻는 방법(simple 붓스트랩)이고, 두 번째는 원 자료에서 붓스트랩을 먼저 시행하고 각 붓 스트랩 표본에서 성향점수 매칭을 하는 방법(complex 붓스트랩)이다. 두 방법의 성능을 비교하기 위하여 다양한 상황을 가정하여 모의실험을 시행한 결과 complex 붓스트랩 방법이 경험적 표준오차와 더 가까운 값으로 추정함을 알 수 있었다. 95% 신뢰구간의 포함확률도 complex 방법을 사용했을 때 0.95에 훨씬 가까웠다. 실제 자료에 적용하였을 때에도 simple 방법은 complex 방법에 비해 표준오차를 작게 추정하였다.

몬테카를로 전산해석을 이용한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자 계산 (Calculation of the Correction Factors related to the Diameter and Density of the Concrete Core Samples using a Monte Carlo Simulation)

  • 이규영;강보선
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.503-510
    • /
    • 2020
  • 콘크리트는 원자력 시설의 차폐용 구조물로 광범위하게 사용되고 있는 재료이다. 하지만, 시설의 해체 시 양적으로 가장 많이 발생하는 방사성 폐기물이기도하다. 콘크리트는 중성자를 포획하여 다양한 방사성 핵종을 생성하기 때문에 해체 전에 시료를 채취하여 방사능 측정 및 평가를 수행해야 한다. 측정은 주로 HPGe 검출기를 이용하는데 시료의 정확한 방사능 판정을 위해는 기하학적 보정인자, 자가흡수 보정인자, 계측기의 절대효율 등 효과적인 보정인자를 측정치에 반영해야 한다. 보정인자는 기하학적 및 화학적 상태가 실제 시료와 동일한 표준시료를 이용해서 동일한 측정조건 하에서 획득한다. 하지만, 콘크리트는 다양한 구성물질과 높은 밀도로 전처리가 제한적이므로 콘크리트 표준시료를 제작하는 것은 매우 어렵다. 또한 코어드릴(core drill)을 사용하여 채취되는 콘크리트 시료는 체적선원이므로 직경에 대한 기하학적 보정과 밀도에 대한 자가흡수에 대한 보정이 필수적이다. 따라서, 최근에는 많은 연구자들이 표준선원을 제작 후 측정하는 대신 몬테카를로 전산모사(Monte Carlo simulation)을 이용하여 효과적인 보정인자들을 계산하는 연구를 수행하고 있다. 본 연구에서는 Monte Carlo code 중 하나인 Geant4를 이용하여 방사화 콘크리트에서 가장 많이 생성되는 핵종인 152Eu, 60Co에서 방출되는 감마선 에너지에 대한 콘크리트 코어시료의 직경과 밀도에 따른 보정인자를 산출하였다.

가중표준편차를 이용한 가변표본채취간격 $\bar{X}$ 관리도 (Variable Sampling Interval $\bar{X}$ Control Chart Using Weighted Standard Deviation Method)

  • 장영순
    • 한국경영과학회지
    • /
    • 제39권1호
    • /
    • pp.1-12
    • /
    • 2014
  • This article proposes a variable sampling interval (VSI) $\bar{X}$ control chart using weighted standard deviation (WSD) method for skewed populations. The WSD method decomposes the standard deviation of a quality characteristic into upper and lower deviations and adjusts control limits and warning limits of a control chart in accordance with the direction and degree of skewness. A control chart constant is derived for estimating the standard deviation of skewed distributions with the mean of sample standard deviations. The proposed chart is compared with the conventional VSI $\bar{X}$ control chart under some skewed distributions. Simulation study shows that the proposed WSD VSI chart can control the in-control average time to signal (ATS) as an adequate level better than the conventional VSI chart, and the proposed chart can detect a decrease in the process mean of a quality characteristic following a positively skewed distribution more quickly than the standard VSI chart.