• Title/Summary/Keyword: standard regulations

Search Result 708, Processing Time 0.023 seconds

A Study of Winterization Design for Helideck Using the Heating Cable on Ships and Offshore Platforms (열선을 이용한 해양플랜트 헬리데크의 방한설계에 관한 연구)

  • Bae, So Young;Kang, Gyu-Hong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In recent years, the demand for ships and offshore platforms that can navigate and operate through the Arctic Ocean has been rapidly increasing due to global warming and large reservoirs of oil and natural gas in the area. Winterization design is one of the key issues to consider in the robust structural safety design and building of ships that operate in the Arctic and Sub-Arctic regions. However, international regulations for winterization design in Arctic condition regulated that only those ships and offshore platforms with a Polar Class designation and/or an alternative standard. In order to cope with the rising demand for operating in the Arctic region, existing and new Arctic vessels with a Polar Class designation are lacking to cover for adequate winterization design with HSE philosophy. Existing ships and offshore platform was not designed based on reliable data based on numerical and experiment studies. There are only designed as a performance and functional purposes. It is very important to obtain of reliable data and provide of design guidance of the anti-icing structures by taking the effects of low temperature into consideration. Therefore, the main objective of this paper reconsiders anti-icing design of aluminum helideck using the heating cable. To evaluate of reliable data and recommend of anti-icing design method, various types of analysis and methods can be applied in general. In the present study, finite element method carried out the thermal analysis with cold chamber testing for performance and capacity of heating cables.

Validation of sequence test method of Pb-free solder joint for automotive electronics (자동차 전장품용 무연솔더 접합부의 시리즈 시험 유효성)

  • Kim, A Young;Oh, Chul Min;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from electronic devices and system. Specifically, reliability issue of lead-free solder joint have an increasing demand for the car electronics caused by ELV banning. The authors prepared engine control unit and cabin electronics soldered with Sn-3.0Ag-0.5Cu (SAC305). To compare with the degradation characteristics of solder joint strength, thermal cycling test (TC), power-thermal cycling test (PTC) and series tests were conducted. Series tests were conducted for TC and PTC combined stress test using the same sample in sequence and continuously. TC test was performed at $-40{\sim}125^{\circ}C$ and soak time 10 min for 1000 cycles. PTC test was applied by pulse power and full function conditions during 100 cycles. Combined stress test was tested in accordance with automotive company standard. Solder joint degradation was observed by optical microscopy and environment scanning electron microscopy (ESEM). In addition, to compare with deterioration of bond strength of quad flat package (QFP) and chip components, we have measured lead pull and shear strength. Based on the series test results, consequently, we have validated of series test method for lifetime and reliability of Pb-free solder joint in automotive electronics.

Comparison on Exhaust Gas of Heavy Duty Diesel Trucks; THC and CO Emission Affected by NOx Control Devices (EGR, SCR) (대형 경유트럭의 NOx 저감장치에 따른 배출가스 특성비교)

  • Mun, SunHee;Yoo, Heung-Min;Son, JiHwan;Yun, Changwan;Park, Gyu Tae;Kim, JeongSoo;Lee, Jongtae
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.149-155
    • /
    • 2015
  • With increasing of GDP, the registration number of passenger cars has exceeded 20 million last year in Korea. Especially, the registration number of the diesel engine vehicles has been increasing. However, the WHO(World Health Organization) IARC (International Agency for Research on Cancer) has reported that diesel engine exhaust gas is an one of HAPs, which has carcinogenic for human, and they have designated it to Group 1. To solve this problem, exhaust gas from diesel engines has to be controlled. Thus, it has been controlling by European regulatory standard in Korea. On the other hand, in order to meet the enhanced emission regulations, all manufacturing company applied $NO_x$ control device to vehicles such as EGR (Exhaust Gas Recirculation), SCR (Selective Catalytic Reduction) and so on. However, these devices (EGR, SCR) were operated by difference reaction mechanism respectively, and the composition of exhaust gas would be differenced from that of them. In this study, it was conducted to evaluate variety characteristics on changing of exhaust gas composition by each $NO_x$ control device, and the heavy duty diesel trucks were chosen as experimental vehicles. From the result, it revealed that vehicles (with EGR) were discharged higher THC as 52.5% than that of others (with SCR). However, it did not followed that trend, in the case of CO; it was discharged as 57.2% lower than that of others (with SCR). In the future, these data would be used to apply to efficient $NO_x$ control device for meeting to EURO 6.

Evaluation of horizontal position Accuracy of Facilities in Digital Map (수치지도 상에 있는 시설물들에 대한 수평위치 정확도 평가)

  • Choi, Seung-Pil;Yang, In-Tae;Cho, Jee-Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.4 s.22
    • /
    • pp.95-103
    • /
    • 2002
  • The accuracy of Digital Map does not meet the user's expectation, including the many errors caused while producing the project, this will be useless resulting waste of enormous national budget. To solve this Accuracy problem, clear regulations about the position accuracy of scaled Digital Map should be set immediately and provide the users with accurate information about Digital Map enabling the users to use Digital Map for each GIS application field. For this reason, the position accuracy evaluation of existing Digital Maps produced in diverse methods is on demand. In this study, therefore, we performed horizontal position survey of local selected Facilities Total Station equipment to evaluate the horizontal position accuracy of 1:1,000, 1:5,000 scaled Digital Map, obtained standard deviation using the results, performed T-Test to confirm the presence of bias and evaluated the position accuracy of Digital Map.

  • PDF

Development of an Hazard Analysis Critical Control Point Application Model for a Olive Flounder (Paralichthys olivaceus) Aquaculture Farm (넙치 양식장 위해요소중점관리기준(HACCP) 적용모델 개발)

  • Kim, Tae-Jin;Min, Jin-Gi;Park, Sun-Mee;Choi, Jae-Suk;Lee, Myung Suk;Kim, Young-Mog;Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.5
    • /
    • pp.1055-1067
    • /
    • 2013
  • We attempted to apply the HACCP system adopted in the food industry to a olive flounder (Paralichthys olivaceus) aquaculture farm to ensure the hygiene safety of farmed fish. In this study, HACCP system procedures, including HACCP team organization, critical point determination, establishment of standard limits etc., were established using Codex 12 procedures. To determine whether hazards were critical elements, we evaluated the likelihood and seriousness of each hazard element. The likelihood of residual medicine exceeding the acceptable limit in shipped fish products was demonstrated to be a critical hazard element. Management of the shipment stage was determined to be a critical control point (CCP). Checking the records for stock and release and maintaining a history of medicine use before shipping the fish were suggested as monitoring methods. The standards for acceptable residual medicine were set based on relevant laws and regulations, and then the limits were adapted and established for the CCP. An HACCP plan applicable to olive flounder farms was established.

A Study on the Changing Trends of Community Spaces in Apartment Complexes in the National Capital from 1960s to 2007 (1960년$\sim$2007년 수도권 아파트단지의 공동생활공간 변화 과정)

  • Lee, Nam-Sik;Suh, Kuee-Sook
    • Journal of the Korean housing association
    • /
    • v.19 no.3
    • /
    • pp.95-104
    • /
    • 2008
  • The purpose of this study is systematically to examine the changes that have taken place to the community spaces of apartment complexes in the national capital region of Korea. The methodology used in this study entails analyzing existing research and case studies carried out on this subject matter. Prior to these case studies, an existing study had been made of the chronological changes in policy, related laws and regulations in Korea since the 1960s. This case study presents the component ratio and systematized present situation of community spaces in twenty-two apartment complexes. An analysis of the researching process has revealed the following important factors related to the changes that have occurred in community spaces in apartment complexes. (1) Apartment complexes were originally developed in the 1960s to ease the housing shortage. Because the priority was to solve the housing shortage, community spaces were not widely considered or developed. (2) The standard of community spaces was established as mandatory by law in the 1970s, resulting in the emergence of various facilities that provided community spaces. (3) In the 1980s, various design competitions for apartment complexes were conducted as an attempt to improve residential environments. This process resulted in the development of new characteristic of subsidiary facilities. (4) During the period when housing problems were being addressed in the 1990s, the Community Service Center was added to the welfare facilities for residents. (5) Recently, during the 2000s, an improvement in residential environments has evolved due to the expansion of housing supply and economic growth. The quality of community spaces has therefore improved from the 1960s onward. This study revealed that policy and related laws regarding community space in Korea have been developing in a suitable direction and that the addition of various facilities to community spaces has improved the quality of living environments.

Effect of Particle Breakage on Compaction and Thermal Resistivity of Concrete-based Recycled Aggregates (콘크리트 재생 순환골재의 파쇄 효과에 따른 다짐 및 열저항 특성 연구)

  • Kang, Sungchul;Kim, Gyeonghun;Wi, Jihae;Ahn, Taebong;Lee, Dae-Soo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.10
    • /
    • pp.17-28
    • /
    • 2015
  • The strict regulations on eco-friendly construction and the significant reduction of natural aggregate resources have raised public concerns on the utilization of recycled aggregates for backfilling a power transmission pipeline trench. In this paper, the particle breakage of concrete-based recycled aggregates and river sand has been experimentally studied during the standard compaction test. The applied compaction energy does not significantly break the river sand particles down, and thus causes no change in the compaction curve, thermal resistivity, and particle gradation characteristics. On the other hand, considerable particle breakage was observed in case of the three recycled aggregates. Such particle breakage leads to enhancing compaction effort, reducing thermal resistivity, and changing particle gradation curve with finer particles that are broken during the first compaction. In addition, particle breakage is more dramatic in lower water contents because pore water may damp down the compaction energy.

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

Study on Weight Reduction of Urban Transit Carbody Based on Material Changes and Structural Optimization (도시철도차량 차체의 경량화를 위한 소재 변경 및 구조체 최적화 연구)

  • Cho, Jeong Gil;Koo, Jeong Seo;Jung, Hyun Seung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1099-1107
    • /
    • 2013
  • This study proposes a weight reduction design for urban transit, specifically, a Korean EMU carbody made of aluminum extrusion profiles, according to size optimization and useful material changes. First, the thickness of the under-frame, side-panels, and end-panels were optimized by the size optimization process, and then, the weight of the Korean EMU carbody could be reduced to approximately 14.8%. Second, the under-frame of the optimized carbody was substituted with a frame-type structure made of SMA 570, and then, the weight of the hybrid-type carbody was 3.8% lighter than that of the initial K-EMU. Finally, the under-frame and the roof-panel were substituted with a composite material sandwich to obtain an ultralight hybrid-type carbody. The weight of the ultralight hybrid-type carbody was 30% lighter than that of the initial K-EMU. All the resulting carbody models satisfied the design regulations of the domestic Performance Test Standard for Electrical Multiple Unit.

A Study on a Permissible Range of the Indicators to Manage Streetscapes by Dynamic Simulation - Focusing on Shape and Layout of Buildings - (동적 시뮬레이션에 의한 도시가로경관 관리지표의 허용범위 연구 - 건축물 형태 및 배치를 중심으로 -)

  • Kim, Doo-Wun;Byeon, Jae-Sang;Im, Seung-Bin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.6
    • /
    • pp.74-83
    • /
    • 2008
  • As urban residents' standard of living has recently risen, efforts to improve urban landscapes have increased. It is very important to manage streetscapes to improve the urban landscape because they are one of the essential elements in city construction and urban landscaping. This study focuses on the indicators that manage streetscapes more accurately and realistically. To achieve this purpose, this study used dynamic simulations considering shape and layout of buildings, the primary factors in streetscapes. This study can be summarized as follows: 1. Two indicators to manage streetscape were investigated in previous studies: one to increase visual openness and the other to reduce visual overstimulation. These indicators had high correlation with scenic beauty. Therefore, increasing openness and reducing overstimulation are essential to improve streetscapes. 2. Two household tower type buildings should be arranged along roadsides to increase openness and scenic beauty. However, low tower buildings with two household are not suitable along roadsides because they create monotony and intervals are needed between buildings. 3. To increase openness, the angled arrangement of buildings is suggested $75^{\circ}{\sim}90^{\circ}(105^{\circ}{\sim}135^{\circ})$ for low buildings, $30^{\circ}{\sim}45^{\circ}(135^{\circ}{\sim}150^{\circ})$ for mid-sized buildings, and $75^{\circ}{\sim}90^{\circ}(105^{\circ}{\sim}135^{\circ})$ for high buildings. 4. To reduce overstimulation, the height and setback control regulations should be at an angle of less than $45^{\circ}$. This study suggests more accurate management guidelines by organizing the indicators that could effectively manage streetscapes and by overcoming limitations of reality shown in a static simulation.