• 제목/요약/키워드: standard penetration resistance

검색결과 72건 처리시간 0.026초

인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구 (A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System)

  • 이정훈;선윤숙;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구 (A Study on the Determination of Depth of Soft Ground by Cone Resistance)

  • 신윤섭;김민철;김연정;김영웅
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF

Spatial interpolation of geotechnical data: A case study for Multan City, Pakistan

  • Aziz, Mubashir;Khan, Tanveer A.;Ahmed, Tauqir
    • Geomechanics and Engineering
    • /
    • 제13권3호
    • /
    • pp.475-488
    • /
    • 2017
  • Geotechnical data contributes substantially to the cost of engineering projects due to increasing cost of site investigations. Existing information in the form of soil maps can save considerable time and expenses while deciding the scope and extent of site exploration for a proposed project site. This paper presents spatial interpolation of data obtained from soil investigation reports of different construction sites and development of soil maps for geotechnical characterization of Multan area using ArcGIS. The subsurface conditions of the study area have been examined in terms of soil type and standard penetration resistance. The Inverse Distance Weighting method in the Spatial Analyst extension of ArcMap10 has been employed to develop zonation maps at different depths of the study area. Each depth level has been interpolated as a surface to create zonation maps for soil type and standard penetration resistance. Correlations have been presented based on linear regression of standard penetration resistance values with depth for quick estimation of strength and stiffness of soil during preliminary planning and design stage of a proposed project in the study area. Such information helps engineers to use data derived from nearby sites or sites of similar subsoils subjected to similar geological process to build a preliminary ground model for a new site. Moreover, reliable information on geometry and engineering properties of underground layers would make projects safer and economical.

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 김연정;김남호;신윤섭
    • 기술발표회
    • /
    • 통권2006호
    • /
    • pp.261-269
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과(N치), 선행압밀하중(pc), 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 $q_c$=(1.09~1.63)N, 선행압밀하중을 고려한 결과 $q_c$=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치($q_c$)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 10kgf/$cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 65~70.0kgf/$cm^2$의 값을 나타내였다.

  • PDF

콘 관입저항치를 이용한 수직배수재 타설심도 결정에 관한 연구 (A Study on the Determination of Construction Depth of Vertical Drain by Cone Resistance)

  • 장서용;김종렬;신윤섭;마봉덕
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.163-170
    • /
    • 2006
  • 최근 피조콘시험은 과거 일반적으로 사용되었던 표준관입시험과 함께 연약지반의 특성을 평가하기 위해 빈번히 사용되고 있다. 본 연구에서는 하부지반의 지층상태를 파악하고 설계를 위한 연약지반 심도 결정 및 시공시 수직배수재 타설심도 결정시 그 신뢰도를 향상시키기 위해서 표준관입시험결과, 선행압밀하중, 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치와의 관계를 분석하였다. 대상 지역별로 일정한 표준관입저항치를 기준으로 평균 연약지반심도를 결정하여, 동일한 심도에서 피조콘관입저항치를 값을 분석한 결과 qc=(1.09~1.63)N, 선행압밀하중을 고려한 결과 qc=(1.21~1.98)N의 관계를 나타내었다. 또한 수직배수재 타설시 관입에너지와 피조콘시험을 통한 콘 관입저항치(qc)와의 관계를 분석한 결과 평균적으로 피조콘 관입저항치 $10kgf/cm^2$의 경우 수직배수재 타설 시 관입저항치는 약 $65{\sim}70kgf/cm^2$ 의 값을 나타내었다.

옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구 (A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs)

  • 오상근;곽규성;선윤숙;권시원
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구 (A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System)

  • 조일규;권시원;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

Seawater curing effects on the permeability of concrete containing fly ash

  • Hosseini, Seyed Abbas
    • Advances in concrete construction
    • /
    • 제14권3호
    • /
    • pp.205-214
    • /
    • 2022
  • Due to seawater's physical and chemical deterioration effects on concrete structures, it is crucial to investigate the durability of these structures in marine environments. In some conditions, concrete structures are exposed to seawater from the first days of construction or because of the lack of potable water, part of the concrete curing stage is done with seawater. In this research, the effects of exposure to seawater after 7 days of curing in standard conditions were evaluated. To improve the durability of concrete, fly ash has been used as a substitute for a part of the cement in the mixing design. For this purpose, 5, 15, and 30% of the mixing design cement were replaced with type F fly ash, and the samples were examined after curing in seawater. The resistance of concrete against chloride ion penetration based on the rapid chloride penetration test (RCPT), water permeability based on the depth of water penetration under pressure, and water absorption test was done. The changes in the compressive strength of concrete in different curing conditions were also investigated. The results show that the curing in seawater has slightly reduced concrete resistance to chloride ion permeation. In the long-term, samples containing FA cured in seawater had up to 10% less resistance to chloride ion penetration. The amount of reduction in chloride ion penetration resistance was more for samples without FA. Whiles, for both curing conditions in the long-term up to 15%, FA improved the chloride ion penetration resistance up to 40%. Curing in seawater slightly increased the penetration depth of water under pressure in samples containing FA, while this increase was up to 12% for samples without FA. In the long-term the compressive strength of samples cured in seawater is not much different from the compressive strength of samples cured in plain water, while at the age of 28 days, due to seawater salts' accelerating effects the difference is more noticeable.

표준관입저항치와 정적콘관입저항치의 상관성에 관한 연구 - 영동지역의 연약지반을 중심으로 - (A Study on the Correlation between Standard Penetration Resistance Value and Static Cone Penetration Resistance Value of the Soft Ground Subsurface of Yongdong Area)

  • 김지남;박흥규
    • 한국지반환경공학회 논문집
    • /
    • 제7권5호
    • /
    • pp.13-20
    • /
    • 2006
  • 현장 지반조사시 널리 사용되고 있는 표준관입시험과 정적콘관입시험을 행하여 상관관계를 구하고 현장에서 채취한 시료를 실내시험을 행하여 현장관입시험과의 상관성에 관하여 비교 분석한 결과 다음과 같은 결론을 얻었다. 표준관입시험의 N값과 Dutch Cone Test의 $Q_c$의 관계는 유기질토 지반에서는 $Q_c=1.93N+0.29$, 점토지반은 $Q_c=2.19N+0.20$, 실트지반은 $Q_c=2.34N+1.06$으로 나타났고, 사질토층의 경우 실트질모래지반은 $Q_c=3.02N+0.54$, 모래지반은 $Q_c=3.47N+0.46$ 으로 나타났으며, 입자가 큰 토층일수록 $Q_c/N$값이 증가하였다. 표준관입시험의 N값과 일축압축강도 $q_u$의 관계는 유기질토는 $q_u=0.11N+0.03$, 점토는 $q_u=0.11N+0.25$, 실트는 $q_u=0.18N-0.03$으로 나타났다.

  • PDF

해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구 (A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement)

  • 채휘영;권순달
    • 한국지반환경공학회 논문집
    • /
    • 제24권12호
    • /
    • pp.5-11
    • /
    • 2023
  • 도로나 태양광 발전시설의 인위적으로 조성된 지반이 집중호우와 같은 강우에 의해서 약화되면서 발생되는 산사태, 토석류 등에 의해 경제적 피해가 발생하고 있다. 인위적으로 조성된 지반의 안정성을 파악하기 위해서 지층의 구성상태, 역학적 특성등의 지반정보 확인이 매우 중요하다. 하지만 조사부지가 대부분 급경사로 이루어지거나 진입로가 대부분 없기 때문에 지반정보를 확인하기 위해 일반적으로 사용되고 있는 시추장비와 표준관입시험의 수행이 쉽지 않다. 본 연구에서는 소형화한 오거시추 장비와 자동낙하장치를 적용한 동적콘관입시험(Dinamic Cone Penetrometer, DCP) 장비를 개발하여 산지태양광 부지에서의 적용성을 확인하기 위하여 콘저항값 및 동적콘관입시험값과 표준관입시험값의 상관관계를 분석하였다. 그 결과 콘저항값은 qc = 0.46 N, 동적콘관입시험값(Nd)는 Nd = 1.58 N으로 기존연구자들의 결과와 유사한 값을 확인하여 그 신뢰성을 확보하였다.