• 제목/요약/키워드: standard measurement methods

검색결과 870건 처리시간 0.033초

직접 측정한 인체치수의 기술적 오차 분석 (Analysis of Technical Error of Manual Measurements)

  • 박진희;남윤자
    • 한국의류학회지
    • /
    • 제40권4호
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

사상체질 진단법의 민감도와 특이도에 관한 연구 (The Study on Sensitivity and Specificity of Sasang Constitution Diagnosis Methods)

  • 장은수;백영화;김호석;이시우
    • 한국한의학연구원논문집
    • /
    • 제13권3호
    • /
    • pp.125-131
    • /
    • 2007
  • Objectives: We intended to know sensitivity, specificity and relation of diagnosis methods of Sasang Constitution. Methods: We compared QSCC II, PSSC, Body measurement dignosis results with gold standard ones which were diagnosed by Sasang Constitution specialist, and analyzed by crosstables to get the sensitivity and specificity of those. Results and conclusions 1. Sensitivity and specificity of one diagnosis method were low, so call, in QSCC II, Taeumin is 49% in sensitivity, 97% in specificity, Soeumin is 67%, 69%, Soyangin is 59%, 75%, in Body measurement, Taeumin is 66%, 89%, Soeumin is 70%, 82%, Soyangin is 49%, 78%. in PSSC, Taeumin is 57%, 90%, Soeumin is 88%, 62%, Soyangin is 18%, 88%. 2. When two diagnosis methods are consistent each other, sensitivity and specificity are more higher than one diagnosis method. 3. When three diagnosis methods are all consistent, sensitivity and specificity are most highest, but in Soyangin, those are decreased comparing with the case of consistency between QSCC II and Body measurement.

  • PDF

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

동적 부하모델 파라미터 추정을 위한 시뮬레이션 기반 최적화 기법 비교 연구 (Comparative Study on Proposed Simulation Based Optimization Methods for Dynamic Load Model Parameter Estimation)

  • 마누엘리토 델카스텔로;송화창;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.187-188
    • /
    • 2011
  • This paper proposes the hybrid Complex-PSO algorithm based on the complex search method and particle swarm optimization (PSO) for unconstrained optimization. This hybridization intends to produce faster and more accurate convergence to the optimum value. These hybrid will concentrate on determining the dynamic load model parameters, the ZIP model and induction motor model parameters. Measurement-based parameter estimation, which employs measurement data to derive load model parameters, is used. The theoretical foundation of the measurement-based approach is system identification. The main objective of this paper is to demonstrate how the standard particle swarm optimization and complex method can be improved through hybridization of the two methods and the results will be compared with that of their original forms.

  • PDF

New Empirical Approach to Enhance The Accuracy of Cannon Tube Erosion Rate

  • Chung, Dong-Yoon;Oh, Myoung-Ho
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.231-232
    • /
    • 2002
  • Various methods that utilize erosion rate measurement of standard cannon, 155mm Howitzer M185, as reference, are being used to calculate erosion rate of an interested unknown cannon tubes. We know ten measured erosion values of the standard cannon from 391 rounds to 4.000. An approximate function fitting these value s is derived. The new erosion equation is also suggested and computer simulations arc presented.

  • PDF

PIXE 분석에 의한 대기에어로졸의 원소분석 -표준시료의 작성 및 정량화- (PIXE Analysis of Aerosol Particles - Preparation of Standard Samples and Calibration Test -)

  • 崔琴簒
    • 한국대기환경학회지
    • /
    • 제7권2호
    • /
    • pp.114-118
    • /
    • 1991
  • Particle Induce X-Ray Emission (PIXE) analysis is one of the most useful methods which can determine the elemental concentration of aerosol particles in nano-gram range. The main purpose of this paper is to establish the measurement system and the procedure of PIXE analysis. The standard samples were prepared to calibrate the PIXE analysis by three different techniques. The linear relationships between the peak counts from PIXE spectra and the mass density from RBS spectra were obtained for each standardized element under the applied measurment geometry and conditions. The sensitivity curves for PIXE analysis were determined from these relationships.

  • PDF

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

표준기어를 이용한 기어 프로파일 정밀측정 알고리즘에 관한 연구 (A Study on Algorithm for Gear Profile Measurement Using a Standard Gear)

  • 이민기;이응석;김광중;박현용
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.555-561
    • /
    • 2012
  • 자동차 변속기 내부에서 동력을 전달하는 헬리컬 기어의 소음 및 진동을 억제하기 위한 하나의 방법으로 정밀하게 가공된 기어를 검사하기 위한 방법에 관한 것이다. 본 연구에서는 측정 기준이 되는 표준 기어와 측정 대상 기어인 워크 기어를 정밀하게 측정하는 알고리즘에 관한 것이다. 기존의 방법은 표준 기어와 모니터 기어를 1회전하여 주파수 방법으로 측정 표준을 위한 마스터링 작업을 수행하였다. 본 연구에서는 제시된 알고리즘을 사용하여 표준 기어와 모니터 기어를 측정하고, 표준 기어와 모니터 기어의 오차를 계산하는 방법을 제시함으로써 기어 측정에 대한 정밀도를 높이도록 하였다. 또한 본 알고리즘을 사용하면 빠른 속도로 측정의 표준이 되는 마스터링 공정을 빠르고 정확하게 측정할 수 있을 것으로 예상된다.

극저준위 방사성 폐기물을 위한 효율적인 ${\gamma}$-선 및 ${\beta}$-선 측정 방법 개발 (Development of Effective ${\gamma}$-ray and ${\beta}$-ray Detection Methods For Low-Level Radioactive Wastes)

  • 곽성우;염유선;김호경;조규성;박주완;김창락;송명재
    • Journal of Radiation Protection and Research
    • /
    • 제26권4호
    • /
    • pp.393-398
    • /
    • 2001
  • 매년 병원에서 사용 후 폐기되는 비가연성 폐기물은 ${\gamma}$-선과 ${\beta}$-선을 방출하지만 방사능은 주변방사능 수준으로 매우 낮다. 이를 측정하기 위한 기존의 방법은 비효율적이고 복잡하므로, 좀더 간단한 방법이 긴요하다. 본 논문에서는 측정 방사선의 특성상 핵종에 따라 다른 측정방법을 사용하였는데, ${\gamma}$-선 방출 핵종은 표준시료로부터 효율곡선식을 도출하여 미지의 방사능을 측정하였다 ${\beta}$-선 방출 핵종은 Monte Carlo 시뮬레이션을 통해 계측 효율을 예측하고 표면장벽형계측기로 측정하여 미지의 방사능 양을 결정하는 새로운 방법을 제시하였다. 연구결과에 의하면 이론적 계산치와 표면장벽형 계측기를 이용하면 전처리를 필요로하는 액체섬광계수기를 이용하지 않고 또한 계측효율을 결정하기 위한 비경제적인 표준시료 측정시험과정 없이도 저에너지 방사선을 약 17% 오차 범위내에서 결정할 수 있다고 판단된다.

  • PDF

유량측정방법에 따른 형산강유량의 불확실도 분석 (Uncertainty Analysis of Hyung San River Discharge due to the methods of Discharge Measurement)

  • 서규우;김수현;김대곤
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1538-1542
    • /
    • 2005
  • This study is to secure more accurate data of the discharge on the measurement by gaining a reliable hydrological data through the comparison the present method of measuring them and the other way that is based ISO. This study suggests the applicable measurement method of the discharge that has reliance through general elements and the analysis of uncertainty by comparing and assaying the data of the Hyung San River that is measured by the present standard. The result of this study makes us realize that we should complement the measurement method of the discharge securing the reliable and accurate hydrological data Hydrological data is very important things to perform domestic river works or install some structure in river or coast. Securing reliable and accurate hydro-data and making a thesis should go on in other to do any construction in river or coast.

  • PDF