• Title/Summary/Keyword: standard measurement methods

Search Result 870, Processing Time 0.027 seconds

Characterization of Elastic, Dielectric and Piezoelectric Properties of piezoelectric Materials

  • Cao, Wenwu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.13-22
    • /
    • 1999
  • Both the resonance and ultrasonic techniques are standard methods far characterizing the physical properties of piezoelectric materials. However, we found that each technique can only offer a few reliable measurements while the rest often have errors or impossible to implement because of the sample requirements. This paper show that one can use the combination of both techniques to achieve much better accuracy and be able to get the complete set of elastic, dielectric and piezoelectric coefficients using fewer samples. Using an ultrasonic spectroscopy we have also measure the dispersion of the ultrasonic velocity and the attenuation up to 65 MHz. Pb(Zr,Ti)O$_3$[PZT] ceramics were used as examples fur both studies.

  • PDF

Purity assessment using quantitative NMR: establishment of SI traceability in organic analysis

  • Choi, Kihwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.30-37
    • /
    • 2020
  • Quantitative nuclear magnetic resonance (qNMR) has been gaining attention as a purity assessment method. In particular, qNMR is recognized as the primary method to realize the Internal System of Units (SI) in organic analysis. The capability of quantitative analysis is recognized as the beginning of NMR development. NMR signals are proportional to the number of nuclei and qNMR has been used in various fields, such as metabolomics and food and pharmaceutical analysis. However, careful sample preparation and thorough optimization of measurement parameters are required to obtain accurate and reliable results. In this review, quantitative methods used in qNMR are discussed, and the important factors to be considered also introduced. The recent development of qNMR techniques including combination with chromatography and, multidimensional NMR are also presented.

Measurement of urinary protein in children

  • Myung Hyun Cho
    • Childhood Kidney Diseases
    • /
    • v.26 no.2
    • /
    • pp.69-73
    • /
    • 2022
  • Proteinuria is an early hallmark of kidney disease and a major risk factor for systemic cardiovascular diseases. There are several methods to measure proteinuria, such as the urine dipstick test, 24-hour urinary protein excretion method, and spot urine for the protein-to-creatinine ratio. The urine dipstick test is simple but inaccurate. The 24-hour urinary protein excretion method is the gold standard; however, it is cumbersome, especially in children. Spot urine for the protein-to-creatinine ratio is simple and accurate, but has limitations. Specific urinary protein such as albumin can be measured instead of the total protein content. Tests should be avoided in situations that cause transient proteinuria or false-positive results. It should be performed correctly, and its limitations should be recognized and interpreted accurately.

PROBABILISTIC MEASUREMENT OF RISK ASSOCIATED WITH INITIAL COST ESTIMATES

  • Seokyon Hwang
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.488-493
    • /
    • 2013
  • Accurate initial cost estimates are essential to effective management of construction projects where many decisions are made in the course of project management by referencing the estimates. In practice, the initial estimates are frequently derived from historical actual cost data, for which standard distribution-based techniques are widely applied in the construction industry to account for risk associated with the estimates. This approach assumes the same probability distribution of estimate errors for any selected estimates. This assumption, however, is not always satisfied. In order to account for the probabilistic nature of estimate errors, an alternative method for measuring the risk associated with a selected initial estimate is developed by applying the Bayesian probability approach. An application example include demonstrates how the method is implemented. A hypothesis test is conducted to reveal the robustness of the Bayesian probability model. The method is envisioned to effectively complement cost estimating methods that are currently in use by providing benefits as follows: (1) it effectively accounts for the probabilistic nature of errors in estimates; (2) it is easy to implement by using historical estimates and actual costs that are readily available in most construction companies; and (3) it minimizes subjective judgment by using quantitative data only.

  • PDF

Change in Exposure Concentration in the Cleaning Process after Installing a Local Exhaust System (디클로로메탄 사용 세척공정의 국소배기장치 설치 후 노출농도 변화)

  • Myung Hwa Cho;Seung gi Kim;Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.280-283
    • /
    • 2023
  • Objectives: The purpose of this study was to examine the change in exposure concentration in the cleaning process after installing a local exhaust system. Methods: Dichloromethane measurement was conducted according to the KOSHA Guide (A-19-2019). Results: After the local exhaust device was installed, a total of three measurements were conducted, including temporary work environment measurements, and all of the measurements did not exceed the DCM exposure standard, but were more than 50% of the DCM Time Weighted Average((8-TWA) Conclusions: It is thought that the local ventilation system of a small business needs not only support for the initial installation cost, but also educational support for maintaining the performance of the local ventilation system and support for consumables (adsorbents, filters, etc.) that incur periodic costs.

Coronary Physiology-Based Approaches for Plaque Vulnerability: Implications for Risk Prediction and Treatment Strategies

  • Seokhun Yang;Bon-Kwon Koo
    • Korean Circulation Journal
    • /
    • v.53 no.9
    • /
    • pp.581-593
    • /
    • 2023
  • In the catheterization laboratory, the measurement of physiological indexes can help identify functionally significant lesions and has become one of the standard methods to guide treatment decision-making. Plaque vulnerability refers to a coronary plaque susceptible to rupture, enabling risk prediction before coronary events, and it can be detected by defining a certain type of plaque morphology on coronary imaging modalities. Although coronary physiology and plaque vulnerability have been considered different attributes of coronary artery disease, the underlying pathophysiological basis and clinical data indicate a strong correlation between coronary hemodynamic properties and vulnerable plaque. In prediction of coronary events, emerging data have suggested independent and additional implications of a physiology-based approach to a plaque-based approach. This review covers the fundamental interplay between coronary physiology and plaque morphology during disease progression with clinical data supporting this relationship and examines the clinical relevance of physiological indexes in prediction of clinical outcomes and therapeutic decision-making along with plaque vulnerability.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Optimization of Immunosasay Procedures for the measurement of Progesterone (Progesterone 측정을 위한 면역분석법의 최적조건에 관한 연구)

  • 강원준;고대환;이경광;김종배;정길생
    • Korean Journal of Animal Reproduction
    • /
    • v.9 no.2
    • /
    • pp.105-112
    • /
    • 1985
  • This research was carried out to investigate the optimal conditions ssociated with the RIA procedures such as a bridging phenomena, prozone effects and a new separation methods etc. The results obtained were summarized as follows: 1. The lgG fractions of donkey anti-rabbit IgG sera were purified by Protein-A-Sepharose affinity column, which indicates that Protein-A an affinity for IgG class of donkey antiserum. 2. In coating the IgG fraction on polystryene tubes, incubation conditions made no differences between 2 hr at room temperature and overnight at 4$^{\circ}C$. 3. There were no significant differences between 1st antibody-coated tube and 2nd antibody-coated tube as a separation method when compared in terms of reproducbility. A better reproducibility may be expected if the titers of 1st antibody for the progesterone to be assayed and of corresponding 2nd antibody are reasonably high. 4. The titers of anti-progesterone antibody for 3H-progesterone and progesterone-11HS-125I were 1:300 and 1:700 in liquid-phase, and 1:100 and 1:300 in solid-phse for the separation methods. 5. A bridging phenomena in which a standard curve is long and shallow were observed when progesterone-11HS-125I was used for the tracer, but not in 3H-progesterone. 6. A prozone effect in a solid-phase system, especially 1st antibody-coated tube method was observed which the degree of inhibition was significantly different although zero bindings look the same. In this case, the titration curve should be made both in the absence and in the presence of a, pp.opriate amount of competiter, standard, respectively.

  • PDF

Comparison of Short-Term Toxicity Tests Based on Feeding Behavior and Temperature Control by Ceriodaphnia dubia (Ceriodaphnia dubia의 먹이섭생 기작과 온도조절에 근거한 급성독성조사법의 비교)

  • Park, Jong-Ho;Lee, Sang-Ill;Cho, Young-Oak
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.48-54
    • /
    • 2004
  • Two methods, a Ceriodaphnia algal uptake suppression test (CAUST) and a new toxicity test based on temperature control (TTBTC) which are based on feeding behaviour and temperature control, respectively, were developed and compared for the adoption as the better methodology for short-term toxicity screening. As previously published by Lee et aI., (1997), the CAUST method is based on the feeding behaviour of C. dubia and requires as little as 1 hour of contact time between C. dubia neonates and toxicant. However, even though CAUST requires only 1 hour of contact time, this method still take many hours for the preparation and measurement. Before the test starts, neonate digestive tracts were cleared by feeding yeast to the daphnids, Neonates were then exposed to toxicant, followed by addition of Scenedesmus subspiatus into the bioassay vessels. Daphnids were examined under the bright-field microscope with the presence of algae (indicated by a green colored digestive tract) or the absence of algae. Uptake indicated no toxic effect, whereas, absence of uptake indicated toxic inhibition. Unlike CAUST, the newly developed method (TTBTC) is based on just temperature control for the toxicity test of C. dubia. Initially, neonates are exposed to toxicants while the temperature of water bath containing media increased to $35.5^{\circ}C$. After 1.25 hour of contact time, the number of the daphnids, either live (no toxic effect) or dead (toxic effect), is counted without the aid of any instrument. In both methods, median effective concentrations ($EC_{50}$ values) were computed based on the results over a range of dosed toxicant concentrations. It showed that TTBTC was as sensitive as the standard 48-hour acute bioassay and CAUST. TTBTC and CAUST were much more sensitive than the I-hour I.Q. test and 30-minute Microtox. This study indicates that TTBTC is an easier and more rapid toxicity test than the standard 48-hour acute bioassay and even CAUST.

Improvement of Shade Structures for Ginseng Cultivation

  • Kim, Seoung Hee;Kim, Min Young;Lee, Sang Bong;Jang, In Bea;Lee, Kyou Seung
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.270-278
    • /
    • 2013
  • Purpose: Using agricultural machinery was not easy in the conventional shading structure, specified as a standard facility by standard cultivation methods for ginseng. Thus, this study designed the new types of facility allowing machine access by modifying the conventional type. Methods: Two types of facility (i.e. wide roof type and long & short roof type) were designed and installed in an experimental site to evaluate its growing environments and applicability of riding-type cultivator. Results: From the results of incoming light measurement, all three types (i.e. two new types and a conventional type) of shading structures blocked the incoming light after 9:00 am. The temperature distribution inside the new types was similar with the one in the conventional type, so the growth of ginseng was in good condition in all three types of facility. The riding-type cultivator was operated well with the low speed first gear of 0.13 m/s in the new types. However, a long & short typed roof needs to be raised 18 cm height in order to use the cultivator. Conclusions: With the results of this study, the new types of roof can be used in the ginseng farm in that they satisfied the growing environments for ginseng and the needs for agricultural mechanization.