• 제목/요약/키워드: standard measurement methods

검색결과 870건 처리시간 0.032초

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • 제65권2호
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

종이 헬리콥터 실험을 통한 개발단계 성능변동의 이해와 개선 (Understanding and Reducing Performance Variation in New Product Development Using Paper Helicopter Experiment)

  • 신병철;김시웅;정순민;변재현;남용석
    • 품질경영학회지
    • /
    • 제43권4호
    • /
    • pp.589-606
    • /
    • 2015
  • Purpose: In developing new products, reducing performance variation is important for competitiveness factors such as quality, cost, and delivery. This paper aims at evaluating three performance variations; measurement, performance evaluation, and manufacturing variations, and then improving product and process design, focused on paper helicopter making case study. Methods: For measurement system analysis, gage R&R (repeatability and reproducibility), linearity, stability are evaluated. Since gage R&R are not satisfactory, the measurement system is improved by adopting voice memos application of iPhone and providing standard measurement procedure. To evaluate performance variation, product deterioration and environment factor (wind speed) is considered. Since the existing design is sensitive to these noise factors, a new product design is developed, which is proven to be robust to the noise factors. Finally, manufacturing variations are evaluated with five factors which can cause variation in flight time. To reduce the impact of three significant factors, three improvement methods are applied. Results: Three performance variations are evaluated and robust paper helicopter design is presented. Conclusion: To reduce measurement and process variations, improved measurement method and paper helicopter making procedure are proposed. A new product design is also presented which is robust to deterioration and environmental variation. This paper is expected to benefit students and practitioners who want to have hands-on knowledge on new product quality improvement.

N값과 전단파 속도의 상관식 비교 (Comparison of Correlation Equations between N value and Shear Wave Velocity)

  • 공진영;채휘영;천병식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.656-665
    • /
    • 2010
  • Shear modulus has been recognized as one of the important soil properties in dynamic analysis of ground and can be calculated from in situ measurement of shear wave velocity. Field seismic tests are the most accurate but expensive methods to investigate dynamic ground characteristics. Due to that reason, empirical equations for estimating the shear wave velocity are widely used rather than conducting in-situ tests. The most common equations are based on the N value obtained in conjuctions with a standard penetration test. In this paper, the field datas of standard penetration test and suspension PS logging measured in 126 sites of Korea were summarized and the correlation equations between N value and shear wave velocity are suggested.

  • PDF

계측시스템 GPIB 인터페이스의 H/M 및 S/W개발 (H/W, S/W Developments of GPIB Interface for Measurement Systems)

  • 나승유;최완규;박민상;배희종;조강석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.1141-1144
    • /
    • 1999
  • GPIB-based measurement applications are common in every field of multi-instrument environment. Also personal computers and workstations play a key role in measurement ability to create cost-effective instrument control solutions. For simple data acquisition systems which are automated by GPIB interface, standard GPIB controllers add a little burden to the budget for DAQ. In this paper, we provide software and hardware construction methods for cost-effective custom-made GPIB controller boards both for controllers and instruments. This way of tailored configuration to suit a particular application of GPIB-based instrument control solution pays dividends in cost and flexibility for data processing management.

  • PDF

ISO/WD 18233 - 건축음향에서의 새로운 측정방법의 적용 (Report on the Research of ISO/WD 18233 - Application of new measurement methods in building acoustics)

  • 국찬;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.851-856
    • /
    • 2003
  • The study on the new measurement method of room acoustics is now in process in the ISO TC43/SC2/WG24 New standard(WD 18233) is dealing with the MLS, swept sinusoidal signal and impulse. This working group is composed of more than 20 specialists in 10 countries and the convener is professor J.H.Rindel in technical university of Denmark. The meeting of WG24 was held in the DIN, Berlin at 23rd. this september and the results was sent to the secretary of ISO TC43/SC2 for the circulation. Brief information of ISO/WD18233 and the result of this meeting is given here.

  • PDF

3차원 안면자동인식기(3D-AFRA)의 Software 정밀도 검사 : 형상측정프로그램 오차분석 (A Software Error Examination of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Measurement of Facial Figure Data)

  • 석재화;송정훈;김현진;유정희;곽창규;이준희;고병희;김종원;이의주
    • 사상체질의학회지
    • /
    • 제19권3호
    • /
    • pp.51-61
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So We should examine the Measurement of Facial Figure data error of 3D Automatic Face Recognition Apparatus(3D-AFRA) in Software Error Analysis. 2. Methods We scanned face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And we measured lengths Between Facial Definition Parameters of facial figure data by Facial Measurement program. 2.1 Repeatability test We measured lengths Between Facial Definition Parameters of facial figure data restored by 3D-AFRA by Facial Measurement program 10 times. Then we compared 10 results each other for repeatability test. 2.2 Measurement error test We measured lengths Between Facial Definition Parameters of facial figure data by two different measurement program that are Facial Measurement program and Rapidform2006. At measuring lengths Between Facial Definition Parameters, we uses two measurement way. The one is straight line measurement, the other is curved line measurement. Then we compared results measured by Facial Measurement program with results measured by Rapidform2006. 3. Results and Conclusions In repeatability test, standard deviation of results is 0.084-0.450mm. And in straight line measurement error test, the average error 0.0582mm, and the maximum error was 0.28mm. In curved line measurement error test, the average error 0.413mm, and the maximum error was 1.53mm. In conclusion, we assessed that the accuracy and repeatability of Facial Measurement program is considerably good. From now on we complement accuracy of 3D-AFRA in Hardware and Software.

  • PDF

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태 (Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China)

  • 정효하;문혜경
    • 급식외식위생학회지
    • /
    • 제2권2호
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

NPE법을 이용한 절연재료의 유효열확산계수의 과도측정에 관한 연구 (A Study on the Transient Measurement of the Effective Thermal Diffusivity of Insulation Materials by NPE Method)

  • 임동주;배신철
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.243-255
    • /
    • 1990
  • The objective of this study is to present an efficient measurement method of the effective thermal diffusivity for the fibrous insulation material. The non-linear parameter estimation (NPE) method is adapted for this analysis because of its accuracy and its results are compared with those by other direct methods such as CTP, CHP and STD method. A experimental system is constructed with bell-jar vaccum chamber, diffusion pump, tube type furnace, control unit and data acquisition system included with A/D converter and IBM XT/AT personal computer. The typical results obtained from this study are as follows; 1) NPE method can be recommended as an useful and accurate method to measure the effective thermal diffusivity of insuation material because it is shown that the measurement error compared with those by other direct methods is reduced for standard material, NBS-1450b. 2) NPE method can minimize the effects of ill-measured temperature due to external disturbance, because the final value is found by point to point estimating. 3) NPE method dose not depend on the kinds of heat flux, since the surfac temperature are used to estimate the thermal diffusivity. 4) With NPE method, compared with the steady state method, a measuring time and a sample size could be reduced.

  • PDF