• Title/Summary/Keyword: standard hospital

Search Result 2,920, Processing Time 0.025 seconds

Development of Evaluation Index for Infection Control and Prevention at Dental Hospital and Its Validity Verification (치과의료기관 감염관리 평가지표 개발 및 타당성 검증)

  • Bae, Sung-Suk;Lee, Myung-Sun
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.254-263
    • /
    • 2013
  • This study is to develop an evaluation index for infection control and to verify its validity by examining each set of weighted data collected from 121 infection control personnel at dental hospitals who agreed to the preliminary survey and advisory. The study was conducted from 14th December, 2010 to 31st January, 2011, and PASW Statistics 18.0 and AMOS 5.0 had been used for the statistical data analysis. As a result of the study, five evaluation factors with 21 sub-indicators have been identified at structural level, eight evaluation factors with 32 sub-indicators at processing level, and one evaluation fact with five sub-indicators at resulting level, total 14 evaluation factors with 58 sub-indicators throughout all levels. The path analysis added on the result that 'standard precautions ($x_1$)', 'infection control support system ($x_2$)', 'internal and external characteristics ($x_3$)' are exogenous variables that affect on other variables, and 'standard infection control ($y_1$)','Organization equipment management handwashing ($y_2$)', 'environmental infection control ($y_3$), 'personal protective equipment ($y_4$)', 'waste and laundry management ($y_5$)' are endogenous variables that are infulenced by others. The standardized metrics are more needed than anything else when examining on infection control. This study attempts to develop proper dental infection control metrics adequately adjusted for domestic circumstances, and therefore to contribute to effective systematic management and decision-making in infection control.

How Many Patients with Mixed Spirometric Pattern Really Have Restrictive Disorders? (폐활량 검사 상 혼합성 환기 장애를 보일 때 실제 얼마나 제한성 장애를 동반하는가?)

  • Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.836-842
    • /
    • 1999
  • Background: Mixed obstructive and restrictive pattern of spirometry can not be concluded in the presence of true restrictive disorders because pure obstructive disorders can also show reduced vital capacity. However, it is not known how many patients with mixed spirometric pattern really have restrictive disorders in Korea whose pattern of pulmonary diseases is somewhat different from foreign countries. To answer this question, I performed this study and tried to answer it according to diseases in addition. Method: Test results from 413 patients who undergone both spirometry and lung volume measurements on the same visit from August 1, 1998 to July 31, 1999 were included. Spirometry data were classified as mixed obstructive-restrictive pattern when spirometry showed '$FEV_1/FVC$<70% (<65% if age$\geq$60)' and FVC<80% of predicted value'. TLC by the method of nitrogen washout was considered as gold standard to diagnose restrictive disorders in which TLC is less than 80% of predicted value. Results: Out of 404 patients who could be evaluated, 58 had mixed pattern of spirometry. 58 patients were suffered from airway diseases(39 patients) such as COPD(22 patients, 38%), asthma(11, 19%), bronchiectasis (6,10%), and sequelae of pulmonary tuberculosis(15, 26%) or other diseases(4,7%). Only 18 out of 58(31%) were confirmed to have true restrictive disorders by TLC. The proportion of true restrictive disorders was different according to diseases, 20.5%(8/39patients) in patients with airway diseases and 53.3%(8/15) with sequelae of pulmonary tuberculosis(p<0.05). Conclusion: Many patients whose spirometry showed mixed pattern didn't have restrictive disorders but had pure obstructive disorders. This was true for more patients with airway diseases. Therefore it would be prudent that lung volume be tested to diagnose restrictive disorders in patients with mixed spirometric pattern.

  • PDF

An Experimental Study on the Excellences of Nurses′ Communication Method upon Psychiatric Patient′s Response. (간호원의 의사소통방법이 정신병환자 반응에 미치는 영향에 대한 실험적 연구)

  • 이평숙
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.2
    • /
    • pp.78-92
    • /
    • 1974
  • It is the purpose of this study to make clear the way in which people can lead a more desirable human life, that is, to ascertain the method of achieving therapeutic change through transaction between nurses and psychiatric patients. The various problems proposed by th9 above-stated aims of study can be shown, such as: What kind of influences does the method of a nurse′s communication have upon the response of psychiatric patients? 1) What are the general methods of communication used by the nurses? 2) Are there any differences between the control group and experimental group in the patients′ "Child" response? 3) Are there any differences between the control group and experimental group in the Patients "Adult" response? 4) What is the most desirable method of communication for therapeutic change in the patients? In an effort to solve the above questions this study attempted and managed to draw a random sampling of 200 patients being accommodated in the National Mental Hospital by dividing them into two groups, experimental groups and control groups, and recording the transactions between nurses and patients. In the course of carrying,: out this study, the experimental group was interviewed by the nurses specially trained In the P.A.C theory. and the control group interviewed at random by the nurses with no special training in communication. Further, the communication between nurses and patients in a free, relaxed atmosphere was allowed only for 15 minutes, whereupon the nurses were requested to make process-recording according to her memory of nurse patient transaction. The process-recording which recorded a series ol transactions between the nurses and the patients was analyzed according to Berne and Harris′transactional Analysis Standard. Through this standard, the writer of this study examined the significance of difference to compare the transactions brought forth between the experimental group and the control group. The following is a summary of the study which the writer of this thesis undertook. Hypothesis to The method of communication which the nurses usually apply to the patients will be higher in "Parent" than in "Adult". The communication which the nurses carried out in the control group turned out to be not significant between "Adult" and "Parent" Accordingly hypothesis 1. carne to be rejected. Hypothesis 2. The patients "Adult" response will be higher in the experimental group than in the control group. According to the result of a CR examination, as the communication showed a significant difference on P〈.01 level′ hypothesis 2 became affirmative. Hypothesis 3. The patients′"Child" response will be higher in the control group than in the experimental group. Hypothesis 3 proved affirmative since it showed an significant degree on P〈.01 level according to the result of a CR examination. Hypothesis 4 "Adult" response of the patient will be higher in frequency by nurses′"Adult" stimulus than nurse′s "Parent" stimulus Chi-square examination revealed significant difference on P〈.05 level. Hypo. 4 is affirmed. The following conclusions are drawn out based on the result of this study. 1) The generally used method of communication stimulus used by nurses for patients proved to be "Adult" and "Parent" in similar proportion. 2) The group in which the nurses could increase the patients "Adult" response proved to be higher in the experimental group than in the control group. Therefore, the communication (or stimulus) which has been applied in the experimental group can be said to be possible method of achieving therapeutic change. 3) Since the patients′"Child" response were higher in the control group than in the experimental group the communication method used In the control group was suggested as the less agreeable method of achieving therapeutic change than that used in the experimental Group. 4) "Adult" response of patient was elicited in significantly greater percentage when the "Adult" stimulus was used by the nurse. Therefore the most desirable method of-communication to give therapeutic change definitely was shown to be the "Adult" stimulus. Recommendations for further studies are as follows: 1) Studies on nurses′role perception in nurse-patient relationships. 2) Studies on patients′response to the method of communication used by nurses according to variables such as sex, social status, educational background, state of health. 3) Application of T.A, method to various groups of patients. 4) Study of various methods to improve student skill in use of process recording.

  • PDF

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

Comparison of Image Quality among Different Computed Tomography Algorithms for Metal Artifact Reduction (금속 인공물 감소를 위한 CT 알고리즘 적용에 따른 영상 화질 비교)

  • Gui-Chul Lee;Young-Joon Park;Joo-Wan Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.541-549
    • /
    • 2023
  • The aim of this study wasto conduct a quantitative analysis of CT image quality according to an algorithm designed to reduce metal artifacts induced by metal components. Ten baseline images were obtained with the standard filtered back-projection algorithm using spectral detector-based CT and CT ACR 464 phantom, and ten images were also obtained on the identical phantom with the standard filtered back-projection algorithm after inducing metal artifacts. After applying the to raw data from images with metal artifacts, ten additional images for each were obtained by applying the virtual monoenergetic algorithm. Regions of interest were set for polyethylene, bone, acrylic, air, and water located in the CT ACR 464 phantom module 1 to conduct compare the Hounsfield units for each algorithm. The algorithms were individually analyzed using root mean square error, mean absolute error, signal-to-noise ratio, peak signal-to-noise ratio, and structural similarity index to assess the overall image quality. When the Hounsfield units of each algorithm were compared, a significant difference was found between the images with different algorithms (p < .05), and large changes were observed in images using the virtual monoenergetic algorithm in all regions of interest except acrylic. Image quality analysis indices revealed that images with the metal artifact reduction algorithm had the highest resolution, but the structural similarity index was highest for images with the metal artifact reduction algorithm followed by an additional virtual monoenergetic algorithm. In terms of CT images, the metal artifact reduction algorithm was shown to be more effective than the monoenergetic algorithm at reducing metal artifacts, but to obtain quality CT images, it will be important to ascertain the advantages and differences in image qualities of the algorithms, and to apply them effectively.

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.

Usefulness of Deep Learning Image Reconstruction in Pediatric Chest CT (소아 흉부 CT 검사 시 딥러닝 영상 재구성의 유용성)

  • Do-Hun Kim;Hyo-Yeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.297-303
    • /
    • 2023
  • Pediatric Computed Tomography (CT) examinations can often result in exam failures or the need for frequent retests due to the difficulty of cooperation from young patients. Deep Learning Image Reconstruction (DLIR) methods offer the potential to obtain diagnostically valuable images while reducing the retest rate in CT examinations of pediatric patients with high radiation sensitivity. In this study, we investigated the possibility of applying DLIR to reduce artifacts caused by respiration or motion and obtain clinically useful images in pediatric chest CT examinations. Retrospective analysis was conducted on chest CT examination data of 43 children under the age of 7 from P Hospital in Gyeongsangnam-do. The images reconstructed using Filtered Back Projection (FBP), Adaptive Statistical Iterative Reconstruction (ASIR-50), and the deep learning algorithm TrueFidelity-Middle (TF-M) were compared. Regions of interest (ROI) were drawn on the right ascending aorta (AA) and back muscle (BM) in contrast-enhanced chest images, and noise (standard deviation, SD) was measured using Hounsfield units (HU) in each image. Statistical analysis was performed using SPSS (ver. 22.0), analyzing the mean values of the three measurements with one-way analysis of variance (ANOVA). The results showed that the SD values for AA were FBP=25.65±3.75, ASIR-50=19.08±3.93, and TF-M=17.05±4.45 (F=66.72, p=0.00), while the SD values for BM were FBP=26.64±3.81, ASIR-50=19.19±3.37, and TF-M=19.87±4.25 (F=49.54, p=0.00). Post-hoc tests revealed significant differences among the three groups. DLIR using TF-M demonstrated significantly lower noise values compared to conventional reconstruction methods. Therefore, the application of the deep learning algorithm TrueFidelity-Middle (TF-M) is expected to be clinically valuable in pediatric chest CT examinations by reducing the degradation of image quality caused by respiration or motion.

Statistical Analysis on Non-Household Unit Water Use for Business Categories (비가정용수의 업종별 사용량 원단위 및 통계적 특성 분석)

  • Lee, Doojin;Kim, Juwhan;Kim, Hwasoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.385-396
    • /
    • 2009
  • Non-household unit water use for each type of business are estimated in this study. The business types are subdivided into forty based on nine categories by the national industrial standard classification, such as office, commerce, public bathing, public water use etc. Correlation analysis and analysis of variance (ANOVA) are applied to obtain statistical characteristics between industrial water use data, surveyed in six cities including Nonsan, Seosan and the National Statistical Bureau and site area, employees number etc. for each detailed business area. As the proposed non-household unit water uses are compared with five surveyed data in USA, it is shown that almost of water uses per unit area are less than those in USA. Non-household unit water uses of 25% cumulative probability water use recommended as efficiency benchmarks among surveyed data in Korea are also less than those in USA. Especially, in the case of water use in school, the average and the range are similar results showing water use range between 0.4 and 6.2 ($l/m^2/day$) as liter per capita day per an unit area, also water use range between 11.9 to 64.0 (l/student/day) as liter per capita day per a person. From the result of correlation analysis with internal and exogenous affecting factors on non-household water use, it can be concluded that a unit area is most appropriate factor as a standard of non-household unit water use. In case of water use in educational business, the number of students including staffs is more correlated than site ares with water use for the settled water consumption tendency. Although the increase and decrease of educational institutes, retail/wholesale store and restaurants are shown remarkable by the temperature as a representative factor, low correlations are shown in water use fluctuation in lodging house and hospital.