• Title/Summary/Keyword: standard body type

Search Result 328, Processing Time 0.036 seconds

Survival Rate on the Small Cyprinidae by PIT Tagging Application (소형 잉어과 어류의 PIT tag 적용을 위한 생존율 평가)

  • Jang, Min-Ho;Yoon, Ju-Duk;Do, Yuno;Joo, Gea-Jae
    • Korean Journal of Ichthyology
    • /
    • v.19 no.4
    • /
    • pp.371-377
    • /
    • 2007
  • The passive integrated transponder (PIT) telemetry is a useful method for investigating fish population dynamics, community structure and migration. It can be applied for small fishes (TL<100 mm) because of its tiny size and light weight. The survival rate of PIT tag was investigated on 4 small size cyprindae fish species, Carassius gibelio langsdorfi (n=34, standard length; $91.9{\pm}0.9mm$, body weight; $21.2{\pm}0.9g$), Hypophthalmichthys molitrix (n=16, SL; $75.1{\pm}0.9mm$, BW; $6.0{\pm}0.2g$), Pseudorasbora parva (n=30, SL; $51.4{\pm}1.1mm$, BW; $2.7{\pm}0.2g$) and Phoxinus phoxinus (n=37, SL; $70.6{\pm}1.4mm$, BW; $8.2{\pm}0.5g$) under age 1 for applicability and effectiveness. We used three type tags including a small (length 11.0 mm, diameter 2.1 mm, weight 0.088 g), middle (20 mm, 3.5 mm, 0.102 g), large (30 mm, 3.5 mm, 0.298 g) size. After 30 days of tag insertion, survival rate of 117 individuals were 58.1% (large tag, 50.0%; middle tag, 57.5%; small tag, 61.4%). Survival rates varied between three types of tags because the abdominal cavity of each individual was different size. The death was due to surgical damage. If we apply tagging systems on field research of the Korean freshwater fish, the PIT tag will be effective method for analyzing fish ecology.

Historical Investigation on Development of Material Structures, Types and Sizes etc. of Packaging of Market Milk in Korea during 1937$\sim$1992-1 (1937$\sim$1992년 한국(韓國)에서 시유(市乳)의 포장재료(包裝材料) 구성 및 형태 등의 변화(變化)에 대한 사적(史的) 고찰(考察)-1)

  • Kim, Duck-Woong
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.12 no.1
    • /
    • pp.63-73
    • /
    • 2006
  • The first packaging of Korean market milk dates back to July 1937 when Seoul Dairy Co-operative (Kyung Seong Dairy Co-operative in those days) used 1 hob (180 ml) glass bottles with either paper caps or cork caps. During 1945-1972, 2 hob (360 ml) glass bottles were produced, and iron caps and egret-shaped plastic film replaced the previously used caps. When there were insufficient numbers of milk bottles, other glass bottles such as soda drink bottles and beer bottles were used instead. Seoul Dairy Co-operative was the only dairy company existing in Korea until Nam Yang Dairy Co. Ltd was founded in March 1964, followed by Hae Tae Dairy Co. Ltd(Tae Han Food Public Corporation in those days) in 1969 and Mae-il Dairy Co. Ltd (Korea Dairy Company in those days) in May 1971. As many other dairy companies along with the above-mentioned companies were established, a variety of dairy products were packaged and marketed. In 1971 Seoul Dairy Co-operative first used triangular-shaped polyethylene film wrappers, and in 1972 Nam Yang Diary was the first company importing sterilized Tetra pak for the packaging of milk. Since 1974 rectangular shaped polyethylene film wrappers and plastic bottles were used. In 1977 the gable top carton pack made of paper was first introduced by Seo Joo Industry Co. Ltd, and its market share increased rapidly with gradual increase in its volume, from 180ml to 200ml, to 250ml, to 500ml and finally to 1,000ml, causing change in the volume of milk consumption. And in Sep. 1987 Pasteur market milk Co. Ltd. first used round type high density polyethylene bottle(body) with low density polyethylene cap of 245g, 490g and 980g volumes respectively.

  • PDF

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices: Dental X-ray Equipment (치과용엑스선장치의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Lee, Jun-Ho;Park, Chang-Won
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.651-660
    • /
    • 2016
  • Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation (사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구)

  • Jung, Mi Wha
    • Korean Journal of Occupational Health Nursing
    • /
    • v.3
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • Biomass and distribution of Antarctic Krill, Euphausia superba, in the Northern part of the South Shetland Islands, Antarctic Ocean (남극 남쉐틀란드 군도 북부 해역의 크릴 분포 및 자원량)

    • KANG Donhyug;HWANG Doojin;KIM Suam
      • Korean Journal of Fisheries and Aquatic Sciences
      • /
      • v.32 no.6
      • /
      • pp.737-747
      • /
      • 1999
    • To estimate biomass and distribution of the Antarctic krill (Euphausia superba), hydroacoustic survey was conducted on board of R/V Yuzhmorgeologiya, which was chartered by Korea Antarctic Research Program (KARP) group from 18 to 21 December 1998, in the northern part of the South Shetland Islands, Antarctic Ocean, The scientific echo sounder (towing body type) used was EK- 500 (SIMRAD, Norway) with echo integrator (BI-500) at 38 kHz frequency and recorded mean backscattering cross-section coefficient (SA) per 1 $mile^2$ of sea surface. Also, Bongo net sampling was carried out to determine the size of krill and CTD (Conductivity, Temperature and Depth) casting to understand physical structure. Water column was divided into 5 layers (22$\~$65 m, 65$\~$115 m, l15$\~$65 m, 165$\~$215 m and 215$\~$315 m) to know vertical distribution of krill biomass. The standard length of krill collected was between 30 mm and 51 mm, and adult krill had single mode (41 mm). Maximum horizontal length of krill patch was about 35 nautical mile and vertical thickness was about 275 m. High density of krill was appeared in frontal area between Circumpolar Deep Water (>$1^{\circ}C$) and very low temperature water mass (< $-0.5^{\circ}C$) that originate from Weddell Sea. According to the results calculated using target strength equation, krill density was totally higher in continental slope and open water areas than in coastal area. In the study area, krill seems to distribute in depth; density was low at first layer ($\={\rho}=17.0\;g/m^2$) and higher at fourth layer ($\={\rho}=40.19\;g/m^2$). The estimated krill biomass at total survey area and water column was about 2.77 million metric ion ($\={\rho}=151.0\;g/m^2$) and coefficient of valiance ( CV, $\%$) was 19.92. The proportions and biomass of krill biomass at each layer were as follows; layer 1 ($11.3\%$, 0.31 million metric ton, CV=16.24), layer 2 ($13.3\%$, 0.37 million metric ton, CV=34.91), layer 3 ($23.7\%$, 0.66 million metric ton, CV=41.5), layer 4 ($26.6\%$, 0.74 million metric ton, CV=27.84) and layer 5 ($25\%$, 0.69 million metric ton, CV= 26.83).

    • PDF

    Clinical Characteristics of precocious puberty girls and Comparison Analysis of GnRH Test results with Diagnosis type (성조숙증 여아들의 임상적 특징 및 진단별 성선자극호르몬 분비호르몬 GnRH (Gonado Tropin Releasing Hormone) 검사결과의 비교분석평가)

    • Kim, Jung-In;Kwon, Won-Hyun;Moon, Ki-Choon;Lee, In-Won
      • The Korean Journal of Nuclear Medicine Technology
      • /
      • v.20 no.2
      • /
      • pp.54-61
      • /
      • 2016
    • Purpose Precocious Puberty is defined as the development of secondary sexual characteristics in girls younger than 8 years, and boys 9 years. Cause premature closure of the epiphysis is a disease that eventually decreases the final adult height. In this study, we retrospectively analyzed to evaluate the diagnostic difference the GnRH (Gonado-tropin-releasing Hormone) stimulation test results with medical records of precocious puberty in girls. Materials and Methods From February 2015 to December 2015 it was enrolled in the girls 118 people who visited the Seoul National University Bundang Hospital, Pediatrics, Endocrinology Internal Medicine. True precocious puberty group (n=57), early puberty group (n=39), were divided into Premature thelarche (n=22) group. A Tanner stage, chronological age, bone age, height, body weight for each group was determined by examining the mean${\pm}$standard deviation. GnRH test result was compared LH (Basal, 30 min, 45 min, 60 min), FSH (Basal, 30 min, 60 min) for each group, Each group LH, FSH Peak value distribution, the mean${\pm}$standard deviation was calculated for the peak LH/LH basal ratio, peak LH/Peak FSH ratio. The significance probability (P-value) between the value of each third group was determined. Results The average height of the true precocious puberty group $131{\pm}14.85$, the mean weight was $28.80{\pm}4.93$, the average chronological age $7.1{\pm}0.81$, the mean bone age was $9.9{\pm}0.9$, The average height of early puberty group was $134{\pm}5.10$, the average weight $28.50{\pm}4.43$, the average chronological age $8.05{\pm}0.03$, the mean bone age was $10.0{\pm}0.62$, The average height of Premature thelarche $129{\pm}6,01$, the average weight was $28.65{\pm}5.98$, the average chronological age $7.02{\pm}0.58$, the mean bone age was $8.04{\pm}1.29$. There was no significant difference when compared to the height and weight. There was a significant difference between the groups in the chronologic age and bone age difference (P <0.0002) True precocious puberty group showed peak LH levels at 30'(82.5%), 45'(12.3%), 60'(5.3%), in Peak FSH 30'(8.8%), 60'(91.2%). Early Puberty group showed high values in Peak LH at 30'(79.5%), 45'(17.9%), 60'(2.6%), in peak FSH levels at 30'(7.7%), 60'(92.32%). In Premature thelarche Group it showed the Peak LH levels at 30'(30%), 45'(59%), 60'(9.09%), Peak FSH levels at 30'(0%) 60'(100%). When compared with the The Peak LH/basal LH ratio, True precocious puberty group was $19.09{\pm}17.15$, early puberty group was $15.23{\pm}10.88$, Premature thelarche group showed significant differences between the three groups as $4.93{\pm}4.36$.(P <0.0001) LH Peak/FSH Peak ratio, true precocious puberty group was $1.222{\pm}0.77$, early puberty group was $1.34{\pm}1.23$, Premature thelarche group showed significant differences between the three groups as $0.3{\pm}0.09$(P <0.0001) Conclusion In order to diagnose the true precocious puberty have a diagnostic value when the LH peak after GnRH stimulation is increased by more than two to three times compared to baseline or a predetermined level or more than 5~10 IU/L increases. GnRH Test is a test for a long time and the patient discomfort due to repeated blood sampling, but the hypothalamus-pituitary gland- gonad axis activity evaluate and is the most basic accurate test in the differential diagnosis of precocious puberty disorders.

    • PDF

    Sensory Information Processing

    • Yoshimoto, Chiyoshi
      • Journal of Biomedical Engineering Research
      • /
      • v.6 no.2
      • /
      • pp.1-8
      • /
      • 1985
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

    • PDF

    High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

    • H.S-Ching;Oh, M.ishi;M.Morimoto
      • Bulletin of the Korean Space Science Society
      • /
      • 1993.10a
      • /
      • pp.17-17
      • /
      • 1993
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

    • PDF

    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.