• 제목/요약/키워드: standard assessment

검색결과 2,330건 처리시간 0.033초

입자상 대기오염물질의 건강 위해성 평가를 위한 국내 농도반응함수 도출 (Concentration Response Functions for Particulate Matter related Health Risk Assessment in South Korea)

  • 하종식
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.202-213
    • /
    • 2017
  • Objectives: HRA (Health Risk Assessment) is an important tool for measuring the health impacts of air pollution. HRA is already being used widely as an important reference for crafting air pollution policies. However, the absence of a domestic CRF (Concentration Response Function) standard, which is a main component for HRA, could cause confusion amongst policy-makers. The purpose of this study is to tabulate a domestic CRF standard for a PM (Particulate Matter)-related HRA. Methods: This study suggested a domestic CRF standard for HRA thorough a literature review. The literature review for meta-analysis was limited to the English language for epidemiological studies published from January 1980 to March 2016. This meta-analysis was conducted by assuming both fixed- and random-effects of CRF. In addition, studies that reported HRA of air pollution for WHO (World Health Organization), the EC (European Commission), and the EPA (Environmental Protection Agency) were reviewed to compare the CRFs of South Korea to the recommended CRFs of WHO, the EC, or the EPA. Additionally, a domestic CRF standard was supplemented by these. Results: Nineteen studies were selected for the CRF for South Korea. Fifty-three CRFs were derived for meta-analysis. CRFs with a standard for PM-related HRA were divided according to the following four criteria: air pollution, exposure characteristics, type of health impact, and age group. Finally, a domestic CRF standard was created comprised of 21 CRFs. Among these, six CRFs were derived from the results of foreign HRA studies. Conclusions: This study is important in that a domestic CRF standard is first suggested. In addition, this study suggests a further area of study for using HRA as a policy tool and a direction of epidemiological study.

토지적성평가(평가체계II)의 검수방안에 대한 연구 (The Overview Standard of Land Suitability Assesment (Assesment System II))

  • 정영동;조규장
    • 대한공간정보학회지
    • /
    • 제12권3호
    • /
    • pp.33-41
    • /
    • 2004
  • 국토의 난개발의 방지를 위해서 도입된 토지적성평가제도는 평가체계 I, II로 구분되어 있다. 평가체계II는 민간 및 지자체 차원에서 발생하는 일정 기준의 개발사업에 대한 토지이용규제의 성격을 가지고 있다. 이 때문에 민간차원의 개발사업에서는 토지에 대한 재산권의 제한을 가할 수 있어, 평가결과에 대한 조작의 유혹이 존재할 수 있다. 이에 따라 적정한 검수 방안이 마련되지 못하면, 난개발방지 및 효율적인 국토이용이라고 하는 제도도입을 위한 목적을 달성할 수 없다. 본 연구에서는 토지적성평가 평가체계II에서 사용되고 있는 각 지표 및 평가 결과에 대한 검수 방안을 제시함으로서, 토지적성평가 제도의 효율적인 지원 및 정착 방안을 제시하였다.

  • PDF

펴지 추론 규칙을 이용한 수행 평가 시스템 (Performance Assessment System using Fuzzy Reasoning Rule)

  • 김광백;조재현
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권1호
    • /
    • pp.209-216
    • /
    • 2005
  • 수행 평가는 평가자에 의한 평가 오류 가능성, 채점의 공정성과 신뢰도, 타당도 문제, 채점 기준의 모호성, 객관성 확보에 대한 어려움 등의 문제가 야기되고 있다 이런한 수행 평가의 문제점을 해결하고 교사와 학생의 수행 평가 결과에 대한 만족도를 높이기 위하여, 본 논문에서는 회계 원리 과목을 대상으로 수행 평가의 각 영역에서 영향을 미치는 요인을 분석하여 퍼지 소속 함수를 설계하고 퍼지 규칙을 정의하여 추론을 적용하여 객관적이고 신뢰성이 높은 수행 평가 방법을 제안하였다 또한 제안된 수행 평가 방법에서 수행 평가 항목은 형성 평가와 과제 평가로 구분하여 소속 함수를 설계하였다. 제안된 퍼지 수행 평가 시스템을 통해 산출된 수행 평가 결과는 평정자의 채점 오류에 대한 부담을 줄일 수 있으며 학생들에 게는 정확한 기준과 일관성 있는 채점을 통해 공평하고 신뢰성 있는 평가 결과를 제공한다.

  • PDF

학의천을 중심으로 본 자연형 하천복원을 위한 하천자연도 평가 (An evaluation of stream naturalness for Close-to-nature stream restoration in case of Hakui Stream)

  • 김동찬;윤영석;박익수
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.315-324
    • /
    • 2003
  • The purpose of this is to evaluate Hakui Stream Naturalness Index(S.N.I). and to find out stats, problems and opportunities of the Hakui stream by assessment standard. Assessment standard is mainly based on physical structure of stream environment. The purpose evaluating sectors and elements are physical form and structure restoration of stream. To find out assessment standard of stream naturalness index, conceptual frame of assessment standard has been established, for which four sections, for example, longitudinal section, lateral section, stream bottom structure and water environment, have been selected. Overall stream naturalness index of the Hakui stream has been distributed at 3rd to 4th grade, and its assessment index accounted for 3.2 to be 3rd grade, and its mode also did 3rd grade. Stream naturalness index of each section was as follows: Longitudinal section index accounted for 3.6 in average to be 4th grade, and later section index did 3.0 to be 3rd grade, and stream bottom structure index did 3.0 to be 3rd grade, and water environment index did 2.7 to be 3rd grade. Analysis of assessment outcome of stream naturalness index has checked status, Problems and opportunities of corresponding stream. Assessment of stream naturalness index of the study provides useful information for restoration of close-to-nature stream, and furthermore has its meaning in checking problems and opportunities of Hakui stream.

  • PDF

압력보상형 유압펌프 신뢰성 시험평가 기술 (Reliability Test Assessment Technique for Pressure Compensation Type Hydraulic Pump)

  • 정동수
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권4호
    • /
    • pp.371-385
    • /
    • 2011
  • Because consumer mostly utilizes company test standard, supplier spends burden of expenses on building test equipments and managing expert manpower to fulfill consumer's various tests. Therefore, it is urgent to standardize test assessment which has a bond of sympathy between consumer and supplier and evaluates reliability of their products. This study develops reliability assessment standard which is composed of 12 test items considering international and domestic test standards, company internal test standards of consumer companies and field conditions. Also this study introduces overall technical procedure on accelerated test with no failure which is used for the main technology of reliability assessment. To verify effectiveness of reliability assessment, the test results are herein analyzed through building the test equipments and performing the test items.

SPA 심사원 능력과 효율성에 관한 연구 (A Study on Assessor's Competence and Efficiency of Software Process Assessment)

  • 이종무;박철수;김만술
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제20권2호
    • /
    • pp.1-20
    • /
    • 2011
  • In this study, we verify the relationship, which is presented by ISO/IEC 15504, between the assessor's competence and the efficiency of assessment. The ISO standard has been developed by many formal trial experiences for the software process assessment. The software process assessment determines the process capability, and makes the software process improvement possible in the development cycle. In the field assessment, third-party and team-based assessments are generally recommended. Therefore assessors' competences are essential to achieve the effectiveness and the efficiency of assessment. Survey data are collected from the third-party process assessment of a real IT industry, and the analysis is done by a causal modelling technique - PLS. Some findings are as follows. Depending on assessors' SE experiences, effects of the assessor's competence are existed, and their standard knowledge and assessment skill are effected each other. And the efficiency of assessment depends on the assessor's competence. In addition, the power analysis is presented and future research is suggested, because of many limitations of this study.

초기 설계단계 에너지 성능평가를 위한 IFC 기반 IDF 변환기 개발 (Development of the IFC based IDF Converter for Energy Performance Assessment in the Early Design Phase)

  • 김인한;김지은;최중식
    • 한국CDE학회논문집
    • /
    • 제16권2호
    • /
    • pp.146-155
    • /
    • 2011
  • As the seriousness of environmental pollution being on a rise, a low carbon and environment-friendly design for energy efficiency has been issued. With respect to energy in the construction industry, an adoption of BIM which is possible for the various energy performance assessments in the early design phase has been actively working on. In the most cases of energy performance assessment, the data compatibility from the lack of standard software and format became a problem and the improvement for data compatibility system has been needed. This study is to develop the IFC based IDF converter as a middleware which connects between BIM software and energy analysis software. For the building energy performance assessment, Energy Plus and IFC are selected for the standard energy analysis software and its file format. Parameters are organized by steps and the integrated material library is built so it is trying to reduce the existing problem of energy software interface as much as possible. The development of IDF Converter will promote the spread of related fields with increasing the BIM standard and the utilization of energy performance assessment.

국내 음용수의 안전성 (Safety of Drinking Water in Korea)

  • 권숙표
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.1-20
    • /
    • 1997
  • The present standard of drinking water quality is not reached to the guidelines of WHO and US EPA recommended. The appraisal of safety is not appropriate by the results of intermittent and limitted analysis. 45 items of drinking water quality are regulated in the Korean standard and 9 items for inspection designated by Seoul City. This report is the results of analysis of the water quality in the water stations of Seoul which are concerned with the items of Korean water quality standard and the priolity pollutnats recommended by WHO. In the results, 45 items of water quality, and the priolity pollutants were not exceeded to the standard and criteria, while DDT, heptachlor-epoxide, THMs, benzo(a)pyrene, Ba, Al, Gross beta, $^{226}$Ra, $^{90}$Sr were detected, the levels were not exceeded to the WHO guidelines. In ordes to evalute the safety of drinking water quality, besides of the existed items of standard, new hazardouse pollutants should be considered monitored continenously. For the regulation of hazardous pollutants, it may be introduced from the risk assessment. According to the relevant assessment, the acceptable risk of pollutants estimated could be applied to set the water quality standard or recommendations or quidelines as well as the number of monitoring.

  • PDF

한국어 TTS 시스템의 객관적인 성능평가를 위한 기초검토 (Basic consideration for assessment of Korean TTS system)

  • 고락환;김영일;김봉완;이용주
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2005년도 춘계 학술대회 발표논문집
    • /
    • pp.37-40
    • /
    • 2005
  • Recently due to the rapid development of speech synthesis based on the corpora, the performance of TTS systems, which convert text into speech through synthesis, has enhanced, and they are applied in various fields. However, the procedure for objective assessment of the performance of systems is not well established in Korea. The establishment of the procedure for objective assessment of the performance of systems is essential for the assessment of development systems for the developers and as the standard for choosing the suitable systems for the users. In this paper we will report on the results of the basic research for the establishment of the systematic standard for the procedure of objective assessment of the performance of Korean TTS systems with reference to the various attempts for this project in Korea and other countries.

  • PDF

A new method to calculate a standard set of finite cloud dose correction factors for the level 3 probabilistic safety assessment of nuclear power plants

  • Gee Man Lee;Woo Sik Jung
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1225-1233
    • /
    • 2024
  • Level 3 probabilistic safety assessment (PSA) is performed to calculate radionuclide concentrations and exposure dose resulting from nuclear power plant accidents. To calculate the external exposure dose from the released radioactive materials, the radionuclide concentrations are multiplied by two factors of dose coefficient and a finite cloud dose correction factor (FCDCF), and the obtained values are summed. This indicates that a standard set of FCDCFs is required for external exposure dose calculations. To calculate a standard set of FCDCFs, the effective distance from the release point to the receptor along the wind direction should be predetermined. The TID-24190 document published in 1968 provides equations to calculate FCDCFs and the resultant standard set of FCDCFs. However, it does not provide any explanation on the effective distance required to calculate the standard set of FCDCFs. In 2021, Sandia National Laboratories (SNLs) proposed a method to predetermine finite effective distances depending on the atmospheric stability classes A to F, which results in six standard sets of FCDCFs. Meanwhile, independently of the SNLs, the authors of this paper discovered that an infinite effective distance assumption is a very reasonable approach to calculate one standard set of FCDCFs, and they implemented it into the multi-unit radiological consequence calculator (MURCC) code, which is a post-processor of the level 3 PSA codes. This paper calculates and compares short- and long-range FCDCFs calculated using the TID-24190, SNLs method, and MURCC method, and explains the strength of the MURCC method over the SNLs method. Although six standard sets of FCDCFs are required by the SNLs method, one standard sets of FCDCFs are sufficient by the MURCC method. Additionally, the use of the MURCC method and its resultant FCDCFs for level 3 PSA was strongly recommended.