• 제목/요약/키워드: stand-alone monitoring system

검색결과 34건 처리시간 0.026초

풍력.태양광 복합 발전 시스템 개발 및 모니터링에 관한 연구 (The study for developing Wind and Photovoltaic power hybrid generation system and monitoring)

  • 박근현;강철웅;임종환;박의장
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.183.1-183.1
    • /
    • 2010
  • Recently, the increased interest in environmental issues has led to extensive research for development of green energy generation systems. However, only one type of generation system may not be sufficient for stand-alone mode because it cannot cope with the irregularity of weather condition. A hybrid generation system is able to make up for the weakness of each system. In this paper, a stand-alone hybrid wind/PV system is developed that can guarantee the stable energy supply. The system is suitable for power supply under 50W, and a vertical savonius type of blade was designed and applied for the wind generation system.

  • PDF

독립형 태양광 발전소의 연 축전지 모니터링장치 개발 (A Monitoring Unit for Lead Storage Batteries in Stand Alone PV Generation Systems)

  • 문채주;김태곤;장영학;김의선;임정민
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.1-7
    • /
    • 2009
  • Use of the PV(photovoltaic) generation system is increased in such areas as remote mountain places or islands at which electrical energy is not serviced. The stand alone PV system is required the power storage products such as battery, fly wheel and super capacitor. Several lead storage batteries are connected in series to get high voltages. The life of lead storage battery is shortened when over charge or over discharge takes place. So, it is needed to control batteries not to be overcharged or be discharged deeply. Voltage of each battery was ignored in former control methods in which overall voltage was used to control charge or discharge battery. In this study, the charging and discharging voltage variations of sealed lead storage batteries with l2V/l.2A were investigated step by step experiments. The results of the test show that one should consider and specify the state of each battery to prevent overcharge or deep discharge. With the basis of the experiments, we designed a monitoring unit to monitor battery voltages simultaneously using micro-controller. The unit measures voltage of 20 batteries simultaneously and displays data on the color LCD monitor with curved line graph. It also sends data to PC using the RS232C communication port. The designed unit was adapted to stand alone PV system with 1kW capacity and lead storage batteries are connected to the PV generation system. The number of lead storage batteries was 10 in series and 12V/250Ah each. Resistive load with 3kW was used for discharging.

1kW 소형 풍력발전기의 진동 성능 모니터링 (Vibration Performance Monitoring of a 1kW Small Wind Turbine Generator)

  • 김석현;남윤수;유능수;박무열;김태형;박해균
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.75-80
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T. Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

교량진동을 이용한 진동형 자가발전기에 대한 연구 (A Study on Stand-Alone Electric Power Generator Using Bridge Vibration)

  • 최남섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.313-316
    • /
    • 2003
  • 본 논문에서는 교량의 건전도 감시용 계측 유닛에 사용되는 충전시스템을 위한 교량의 상시진동을 이용한 자립형 진동발전기에 대하여 연구하였다. 본 연구에서는 전기자 반작용의 영향을 최소화한 진동발전기를 제안하고, 기계적 및 전기적인 설계식을 유도한 다음, 시험용 진동발전기를 제작하였다. 아울러, 실내 자유진동 실험을 수행하였고, 축전시스템에 대한 실험 결과, 정류기에 사용된 다이오드 특성이 충전과정에서 지배적임을 확인하였다. 또한, 남해대교의 진동 데이터를 Pilot 발전기에 적용하여 시뮬레이션 한 결과 진동발전기의 적용성과 효용성을 확인할 수 있었다.

  • PDF

Design and Analysis of a Power Control and Monitoring System for Buoy

  • Oh, Jin-Seok;Jo, Kwan-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권7호
    • /
    • pp.1068-1074
    • /
    • 2009
  • This paper describes a study for the buoy which should be operated by a stand-alone power system. The field of this study is related to a power system operated by two batteries which depends on the load power. The fluctuation of the voltages makes the life cycle of the battery shorten. The control algorithm has been proposed for reducing the voltage pulsation of the battery by operation strategy according to using purpose such as main or sub power supply system. The power system with battery is separated two parts and this has been proved through a simulation and a sea experiment. In order for the experiment to use a wireless monitoring system has been installed in buoy. This paper shows an excellent test result of wireless monitoring system for buoy.

독립헝 태양광 발전 시스템의 제어 알고리즘에 관한 연구 (The Study of Control Algorithm for Stand alone PV System)

  • 김태엽;정맹화;고권성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1382-1384
    • /
    • 2002
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using flooded type battery in this system is inappropriate. The valve regulated lead acid batter.(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF

A Study on the PCS Characteristics of a 10kW BIPV System

  • Yoon, Hyung-Sang;Cha, In-Su;Yoon, Jeong-Phil;Lee, Jeong-Il;Seo, Jang-Su
    • Journal of Power Electronics
    • /
    • 제8권2호
    • /
    • pp.163-170
    • /
    • 2008
  • A BIPV(Building Integrated PV) system is united by a constituent outer covering and can expect dual effects that reduce expenses for the establishment of a PV system. It is a profitable technology because it does not need a building as it is a stand alone PV system. In this paper, output characteristics analysis of PCS and web-based monitoring of 10kW BIPV, were stimulated and examined for validity. The BIPV system proposed in this paper was established in at BIC (Biotechnology Industrialization Center) of Dongshin University, which was composed with PCS and Web-monitoring system.

IR 및 UV센서를 이용한 레이저 용접시의 실시간 모니터링 DSP 시스템 (A DSP System for On-line Monitoring in Laser Welding Using a IR and UV Sensors)

  • 윤충섭
    • Journal of Welding and Joining
    • /
    • 제23권4호
    • /
    • pp.53-58
    • /
    • 2005
  • We designed a weld monitoring system with UV and IR sensors using a embedded DSP controller for implementing a distribution system; running stand alone and communication with outside by industrial standard protocols. Also this system provided a USB port in order to be acquiring data in PC. The user interface program in PC visualized the IR and W data in time, frequency and state space. A correlation of IR and UV signals showed closely related to weld quality. A rapid change of geometry can be found through a moving average filter. And the average value of IR signal at an interval represented a welding width and depth. Through these results, we proposed a monitoring algorithm for a integer type DSP.

CNC 공작기계의 절삭력 감지를 위한 주축모터의 역률 및 마찰특성에 관한 연구 (Study on Spindle Motor's Power-Factor and Frictional Characteristics For Cutting Force Monitoring in a CNC Machine)

  • 홍성함;이병휘;허건수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.141-146
    • /
    • 2002
  • Real-time monitoring and control of the cutting force is essential for unmanned cutting process. Although the cutting force can be measured directly using tool dynamometers, their implementation is not feasible in industry due to high cost. Alternative approach is the cutting force estimation based on spindle drive models, but it requires the knowledge of their characteristics with the spindle speed variation. This paper investigates the power-factor and frictional characteristics of three-phase induction motors and determines its characteristics below and above the base speed, respectively. In order to realize the proposed cutting force monitoring system, a stand-alone DSP board was utilized. Its monitoring and control performance is evaluated in a CNC lathe.

  • PDF

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.