• 제목/요약/키워드: stainless steel wire mesh

검색결과 15건 처리시간 0.02초

다중적층 소재 레이저용접 인자별 열영향 해석 (Parametric Analysis of Thermal Effects on Multi Layered Laser Welding)

  • 최세훈;최해운
    • 한국기계가공학회지
    • /
    • 제20권8호
    • /
    • pp.18-24
    • /
    • 2021
  • Polymers, polymer compounds, are very moldable at low temperatures and have good strength against weight, and hence, are often used in the interior and exterior materials of cars. Owing to the increasing environmental problems, emission regulations have become stricter, which has increased the use of lightweight polymers as substitutes for metal materials. Therefore, as the use of polymer increases, extensive research is being conducted on the bonding technology of polymers, such as polyurethane and epoxy. However, the increased cost and environmental pollution by adhesives caused by the polymer manufacturing plant depend on the chemical composition or the manufacturer's mix ratio. To compensate for this issue, a laser beam is irradiated through a highly permeable polymer (PC) placed on top of an absorbent polymer (ABS) to transfer the laser output to the ABS polymer and fuse them at the interface. Moreover, enabling laser penetrating bonding by placing a stainless steel wire mesh between the two polymers can achieve improved bonding strength compared to conventional heterogeneous polymer bonding.

Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구 (A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics)

  • 임강순;차경석;이진우
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.303-312
    • /
    • 2004
  • 전치의 후방 견인시 교정력은 치아의 저항중심에서 벗어난 브라켓을 통해 적용되기 때문에 바람직하지 못한 경사이동이 발생하게 되고 이를 방지하기 위한 여러 가지 방법 중 호선에 curve나 전치부 호선에 치근 설측 토그를 부여하는 방법이 많이 사용된다. 이에 본 연구는 combination loop archwire와 hook을 이용한 활주역 학을 이용하여 전치를 후방 견인 시, compensating curve를 0도, 15도, 30도 부여하고, 이 때 나타나는 효과를 광탄성법으로 비교 연구하기 위하여 치아와 치조골 모형을 광탄성 모형으로 대체시키고 와이어와 브라켓을 주어진 조건으로 위치시 킨 후 편광판을 이용하여 초기 응력 상태를 분석하여 다음과 같은 결과를 얻었다. 1. Combination loop archwire와 활주역학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 전치부 치근단 부위의 최대 무의차수가 감소하였다. 2. Combination loop archwire와 활주역 학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 견치와 소구치 부위의 최대 무의차수가 증가하였다. 3. Combination loop archwire로 전치를 견인할 때보다 동일한 힘을 사용하여 활주역 학으로 견인할 때 전치부 치근단 부위에서 다소 낮은 무의차수를 나타내었다. 이상의 결과에서 Combination loop archwire와 활주역학을 이용한 상악전치의 후방 견인시 견인방법에 큰 차이 없이 호선에 부여한 compensating curve는 전치의 설측 경사이동 양상을 어느 정도 감소시킬 수 있음을 확인하였다. 또한 힘의 적용위치가 저항중심에 더욱 가까운 hook을 이용한 활주 역학이 전치의 설측경사 방지에 더 효과적일 것으로 판단된다.가 높게 나타나는 현상을 부분적으로 설명하여 주는 것으로 사료된다.용한 정보를 제공할 수 있을 것으로 보인다.ing할 경우, arch perimeter의 증가량은 Curve of Spee의 최대 길이의 1/2보다 적게 나타났다.$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $61\%$ 수준이었으며, Non-etched Foil-Mesh base에서 최저 Peel 결합 강도$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $55\%$ 수준이었다. 4. 단위 면적 당 결합강도에 있어서 전단결합강도(SBS)와 인장결합강도(TBS) 및 $75^{\circ}\;와\;90^{\circ}$ peel 결합강도는 Micro-Loc base와 Chessboard base에서 차이 가 없었으며 Non-etched Foil-Mesh base에서 가장 작았고(p<0.05), $0^{\circ},\;15^{\circ},\;30^{\circ},\;60^{\circ}$ peel응력을 적용한 결과 Chessboard base에서 가장 큰 Peel결합강도를, Non-etched Foil-Mesh base에서 가장 작은 결합강도를 보였다(p<0.05).았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적 매끄러운 표면을 보이고, Unitek사의 경우 압흔과 함께 pitting 이 관찰되며, Ormco Stainless Steel의 경우 불규칙한 pitting이 다수 존재했다

Torque control during lingual anterior retraction without posterior appliances

  • Mo, Sung-Seo;Kim, Seong-Hun;Sung, Sang-Jin;Chung, Kyu-Rhim;Chun, Yun-Sic;Kook, Yoon-Ah;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제43권1호
    • /
    • pp.3-14
    • /
    • 2013
  • Objective: To evaluate the factors that affect torque control during anterior retraction when utilizing the C-retractor with a palatal miniplate as an exclusive source of anchorage without posterior appliances. Methods: The C-retractor was modeled using a 3-dimensional beam element (0.9-mm-diameter stainless-steel wire) attached to mesh bonding pads. Various vertical heights and 2 attachment positions for the lingual anterior retraction hooks (LARHs) were evaluated. A force of 200 g was applied from each side hook of the miniplate to the splinted segment of 6 or 8 anterior teeth. Results: During anterior retraction, an increase in the LARH vertical height increased the amount of lingual root torque and intrusion of the incisors. In particular, with increasing vertical height, the tooth displacement pattern changed from controlled tipping to bodily displacement and then to lingual root displacement. The effects were enhanced when the LARH was located between the central and lateral incisors, as compared to when the LARH was located between the lateral incisors and canines. Conclusions: Three-dimensional lingual anterior retraction of the 6 or 8 anterior teeth can be accomplished using the palatal miniplate as the only anchorage source. Using LARHs at different heights or positions affects the quality of torque and intrusion.

조직 배양 모형에서 정상 구강 점막 상피에 대한 국소 유전자 요법 (TOPICAL GENE DELIVERY TO NORMAL ORAL EPITHELIUM USING ADENOVIRUS IN ORGAN CULTURE MODEL)

  • 김태환;곽명호;이춘호;박준우;박영욱;김성곤
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권3호
    • /
    • pp.193-197
    • /
    • 2009
  • Background: Though it is clear that many types of viruses can infect the oral mucosa, its condition for infection is unclear. The purpose of this study was to analyze the conditions for viral infection of normal oral mucosa and explore the possibility of topical gene therapy to oral mucosa using a viral vector. Methods: Freshly taken fragments of the palate and the tongue of mice were used for organ culture. The specimens were exposed to green fluorescent protein (GFP)-adenoviral vector for 1 hour except for the control. Initial viral titer was $6.3{\times}10^{11}\;pfu/ml$ and the virus was diluted to working concentrations. The dilution ratio was 1:1,000 ($6.3{\times}10^8\;pfu/ml$), 1:10,000 ($6.3{\times}10^7\;pfu/ml$), and 1:100,000 ($6.3{\times}10^6\;pfu/ml$). They were then cultured on a stainless steel wire mesh in an organ culture dish. The specimens were stereoscopically examined every 24 hours for 6 days, after which they were fixed and analyzed through immunohistochemical methods Results: There was no visible expression in the control, $6.3{\times}10^6\;pfu/ml$, and $6.3{\times}10^7\;pfu/ml$ groups. Initial expression was observed at 24 hours after infection in both the palate and the tongue in $6.3{\times}10^8\;pfu/ml$ and the expression significantly increased until 3 days in the palate and 2 days in the tongue after infection (P<0.05). In both groups, the expression was mostly observed at the resection margin. Immunohistochemical studies showed that the epithelial cells were positive to GFP. Conclusion: The present study showed that topically applied adenovirus containing specific genetic information of GFP could successfully transduce GFP in normal oral epithelial cells at the resection margin in organ culture in terms of dose and exposure time.

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • 제30권4호
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.