• Title/Summary/Keyword: stacking structure

Search Result 331, Processing Time 0.024 seconds

TEM Observations on the Blue-green Laser Diode (청녹색 레이저 다이오드 구조에 관한 TEM 관찰)

  • Lee, Hwack-Joo;Ryu, Hyun;Park, Hae-Sung;Kim, Tae-Il
    • Applied Microscopy
    • /
    • v.27 no.3
    • /
    • pp.257-263
    • /
    • 1997
  • Microstructural characterizations of II-VI blue laser diodes which consist of quaternary $Zn_{1-x}Mg_xS_ySe_{l-y}$ cladding layer, ternary $ZnS_ySe_{l-y}$ guiding layer and $Zn_{0.8}Cd_{0.2}Se$ quantum well as active layer were carried out using the transmission electron microscope working at 300 kV. Even though the entire structure is pseudomorphic to GaAs substrate, the structure had contained numerous extended stacking faults and dislocations which had created at ZnSe/GaAs interfaces and then further grown to the top of the epilayers. These faults might be expected to cause the degradation and shortening the lifetime of laser devices.

  • PDF

An Energy Absorption Characteristic of Thin-Walled Structure Members by Crushing Load (충돌에 의한 차체 박육구조부재의 에너지 흡수특성에 관한 연구)

  • Yang, I.Y.;Sim, J.K.;Kim, S.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.5
    • /
    • pp.74-81
    • /
    • 1995
  • In this paper, the crushing tests of circular tubes under axial impact loading are conducted to investigate the energy absorption abilities. A cross head with 18kg launched by the compressed air collides against circular tubes. Circular tubes used for this experiment are Al and CFRP laminates, which have 8 ply with $15^{\circ}$ and $45^{\circ}$. The absorbed energy unit mass and volume of the CFRP specimen with $15^{\circ}$ are higher than those of aluminum specimen. CFRP specimen having small stacking angle have better energy absorption abilities than that of large stacking angle.

  • PDF

A TEM Investigation on the Crystal Structure of $C_{60}$ Thin Crystals ($C_{60}$ 얇은 결정의 결정구조에 관한 투과형전자현미경 연구)

  • Song, Se-Ahn;Kim, Sung-Hoon;Suh, Young-Doug;Kim, Seong-Keun
    • Applied Microscopy
    • /
    • v.21 no.2
    • /
    • pp.67-75
    • /
    • 1991
  • [ $C_{60}$ ] molecule, the Buckminsterfullerene, has generated great interest because of its unique molecular structure and of superconductivity exhibited in its alkali-doped solids. We have investigated the molecular stacking and crystal structure of $C_{60}$ thin crystals formed on amorphous carbon film. The $C_{60}$ powder which was chromatographically purified was dissolved in benzene. The thin crystals of $C_{60}$ were observed with a 300 keV transmission electron microscope. Electron diffraction analysis and direct imaging of its molecular stacking were carried out. It was found from this work that the molecules of $10.0{\AA}$ diameter are arrayed hexagonally on substrate surface and $8.7{\AA}$ lattice planes are quite often found in several types of ED patterns, which can never be explained with a fcc model. Therefore the structure of $C_{60}$ thin crystals is hcp, although we cannot fully exclude the possibility of co-existence of hcp and fcc.

  • PDF

Study on the Water-Vapor Permeation through the Al Layer on Polymer Substrate (폴리머 기판에 형성한 알루미늄 보호막의 수분침투 특성 연구)

  • Choi, Young-Jun;Ha, Sang-Hoon;Park, Ki-Jung;Choe, Youngsun;Cho, Young-Rae
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.873-880
    • /
    • 2009
  • Water-vapor permeation through metallic barriers deposited on polymer substrates has been an important technological issue because the performance of the barrier is critical to the reliability of flexible organic devices. For the development of long-lifetime flexible organic devices, two different sets of samples were designed and demonstrated from the viewpoint of the water-vapor transmission rate (WVTR). Aluminum (Al) and polyethylene terephthalate (PET) were chosen for the barrier layer and the polymer substrate, respectively. Two stacking structures, a single-layer (Al/PET) structure and a double-layer (Al/PET/Al) structure, were used for the WVTR measurement. For the single-layer structure, the WVTR decreases as the thickness of the barrier layer increases. Compared to the single-layer sample, the double-layer sample showed superior WVTR performance (by nearly three times) when the total thickness of the Al barrier was greater than 100 nm.

Microstructural Observations on Quaternary ZnMgSSe/GaAs Epilayer Grown by MBE (MBE로 성장시킨 4원계 ZnMgSSe/GaAs 에피층의 미세구조 관찰)

  • Lee, Hwack-Joo;Ryu, Hyun;Park, Hae-Sung;Kim, Tae-Il
    • Applied Microscopy
    • /
    • v.25 no.3
    • /
    • pp.82-89
    • /
    • 1995
  • High resolution transmission electron microscopic observations on quaternary $Zn_{1-x}Mg_{x}S_y$ $S_{1-y}$(x=0.13, y=0.16) on (001) GaAs substrate grown up to $1.2{\mu}m$ with 20nm ZnSe buffer layer at $300^{\circ}C$ by RIBER MBE system which has a single growth chamber were investigated by HRTEM working at 300kV with point resolution of 0.18nm. The ZnSe buffer layer maintains the coherency with the GaAs substrate. The stacking faults had begun at ZnSe buffer/$Zn_{1-x}Mg_{x}S_{y}S_{1-y}$ interface, whose length and spacing became larger than 60nm and wider than 40nm, respectively. The inverse triangular stacking fault was bounded by stacking faults which were formed on {111} planes with different variants. There exists rare stacking faults inside the triangular defect. The epilayer surrounded by the straight stacking faults, which had formed in the same direction, became the columnar structure.

  • PDF

Mesoporous Assembly of Layered Titanate with Well-Dispersed Pt Cocatalyst

  • Jung, Tae-Sung;Kim, Tae-Woo;Hwang, Seong-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.449-453
    • /
    • 2009
  • A mesoporous assembly of layered titanate with well-dispersed Pt cocatalysts has been synthesized via a restacking of exfoliated titanate nanosheets and a simultaneous adsorption of Pt nanoparticles. According to powder X-ray diffraction analysis, the obtained mesoporous assembly shows amorphous structure corresponding to the disordered stacking of layered titanate crystallites. Field emission-scanning electron microscopy and $N_2$ adsorption-desorption isotherm measurement clearly demonstrate the formation of mesoporous structure with expanded surface area due to the house-of-cards type stacking of the titanate crystallites. From high resolution-transmission electron microscopy and elemental mapping analyses, it is found that Pt nanoparticles with the size of ~2.5 nm are homogeneously dispersed in the mesoporous assembly of layered titanate. In comparison with the protonated titanate, the present mesoporous assembly of layered titanate exhibits better photocatalytic activity for the photodegradation of organic molecules. This finding underscores that the restacking of exfoliated nanosheets is quite useful not only in creating mesoporous structure but also in improving the photocatalytic activity of titanium oxide.

Low Velocity Impact Property of CF/Epoxy Laminate according to Interleaved Structure of Amorphous Halloysite Nanotubes (비정질 할로이사이트 나노입자의 교차적층 구조에 따른 탄소섬유/에폭시 라미네이트의 저속 충격 특성)

  • Ye-Rim Park;Sanjay Kumar;Yun-Hae Kim
    • Composites Research
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2023
  • The stacking configuration of fiber-reinforced polymer (FRP) composites, achieved via the filament winding process, exhibits distinct variations compared to conventional FRP composite stacking arrangements. Consequently, it becomes challenging to ascertain the influence of mechanical properties based on the typical stacking structures. Thus, it becomes imperative to enhance the mechanical behavior and optimize the interleaved structures to improve overall performance. Therefore, this study aims to investigate the impact of incorporating amorphous halloysite nanotubes (A-HNTs) within different layers of five unique layer arrangements on the low-velocity impact properties of interleaved carbon fiber-reinforced polymer (CFRP) structures. The low-velocity impact characteristics of the laminate were validated using a drop weight impact test, wherein the resulting impact damage modes and extent of damage were compared and evaluated under microscopic analysis. Each interleaved structure laminate according to whether nanoparticles are added was compared at impact energies of 10 J and 15 J. In the case of 10 J, the absorption energy showed a similar tendency in each structure. However, at 15 J, the absorption energy varies from structure to structure. Among them, a structure in which nanoparticles are not added exhibits the highest absorption energy. Additionally, various impact fracture modes were observed in each structure through optical microscopy.

Mold-Flow Simulation in 3 Die Stack Chip Scale Packaging

  • Rhee Min-Woo
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2005.09a
    • /
    • pp.67-88
    • /
    • 2005
  • Mold-Flow 3 Die Stack CSP of Mold array packaging with different Gate types. As high density package option such as 3 or 4 die stacking technologies are developed, the major concerning points of mold related qualities such as incomplete mold, exposed wires and wire sweeping issues are increased because of its narrow space between die top and mold surface and higher wiring density. Full 3D rheokinetic simulation of Mold flow for 3 die stacking structure case was done with the rheological parameters acquired from Slit-Die rheometer and DSC of commercial EMC. The center gate showed severe void but corner gate showed relatively better void performance. But in case of wire sweeping related, the center gate type showed less wire sweeping than corner gate types. From the simulation results, corner gate types showed increased velocity, shear stress and mold pressure near the gate and final filling zone. The experimental Case study and the Mold flow simulation showed good agreement on the mold void and wire sweeping related prediction. Full 3D simulation methodologies with proper rheokinetic material characterization by thermal and rheological instruments enable the prediction of micro-scale mold filling behavior in the multi die stacking and other complicated packaging structures for the future application.

  • PDF

Impact Collapse Behavior of Hybrid Circular Thin-walled Member by Stacking Condition (적층조건에 따른 혼성 원형 박육부재의 충격압궤거동)

  • Lee, Kil-Sung;Park, Eu-Ddeum;Yang, In-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.235-240
    • /
    • 2010
  • The recent trend of vehicle design aims at crash safety and environmentally-friendly aspect. For the crash safety aspect, energy absorbing members should be absorbed with collision energy sufficiently. But vehicle structure must be light weight for the environmentally-friendly aspect, in order to improve fuel efficiency and to reduce tail gas emission. Therefore, the light weight of vehicle must be achieved in a status of securing safety of crash. An aluminum or CFRP (Carbon Fiber Reinforced Plastics) is representative one among the light-weight materials. In this study, impact collapse behavior of circular hybrid thin-walled member is evaluated. The hybrid members are manufactured by wrapping CFRP prepreg sheets outside the aluminum circular members in the autoclave. Because the CFRP is an anisotropic material whose mechanical properties change with its stacking condition, special attention is given to the effects of the stacking condition on the collapse behavior evaluation of the hybrid thin-walled member. Collapse mode and energy absorption capability of the hybrid thin-walled member are analyzed with change of the fiber orientation angle and interface number.