• Title/Summary/Keyword: stacked

Search Result 1,132, Processing Time 0.033 seconds

GLOBAL Hɪ PROPERTIES OF GALAXIES VIA SUPER-PROFILE ANALYSIS

  • Kim, Minsu;Oh, Se-Heon
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.5
    • /
    • pp.149-172
    • /
    • 2022
  • We present a new method which constructs an Hɪ super-profile of a galaxy which is based on profile decomposition analysis. The decomposed velocity profiles of an Hɪ data cube with an optimal number of Gaussian components are co-added after being aligned in velocity with respect to their centroid velocities. This is compared to the previous approach where no prior profile decomposition is made for the velocity profiles being stacked. The S/N improved super-profile is useful for deriving the galaxy's global Hɪ properties like velocity dispersion and mass from observations which do not provide sufficient surface brightness sensitivity for the galaxy. As a practical test, we apply our new method to 64 high-resolution Hɪ data cubes of nearby galaxies in the local Universe which are taken from THINGS and LITTLE THINGS. In addition, we also construct two additional Hɪ super-profiles of the sample galaxies using symmetric and all velocity profiles of the cubes whose centroid velocities are determined from Hermite h3 polynomial fitting, respectively. We find that the Hɪ super-profiles constructed using the new method have narrower cores and broader wings in shape than the other two super-profiles. This is mainly due to the effect of either asymmetric velocity profiles' central velocity bias or the removal of asymmetric velocity profiles in the previous methods on the resulting Hɪ super-profiles. We discuss how the shapes (𝜎n/𝜎b, An/Ab, and An/Atot) of the new Hɪ super-profiles which are measured from a double Gaussian fit are correlated with star formation rates of the sample galaxies and are compared with those of the other two super-profiles.

Study of monolithic 3D integrated-circuit consisting of tunneling field-effect transistors (터널링 전계효과 트랜지스터로 구성된 3차원 적층형 집적회로에 대한 연구)

  • Yu, Yun Seop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.5
    • /
    • pp.682-687
    • /
    • 2022
  • In this paper, the research results on monolithic three-dimensional integrated-circuit (M3DICs) stacked with tunneling field effect transistors (TFETs) are introduced. Unlike metal-oxide-semiconductor field-effect transistors (MOSFETs), TFETs are designed differently from the layout of symmetrical MOSFETs because the source and drain of TFET are asymmetrical. Various monolithic 3D inverter (M3D-INV) structures and layouts are possible due to the asymmetric structure, and among them, a simple inverter structure with the minimum metal layer is proposed. Using the proposed M3D-INV, this M3D logic gates such as NAND and NOR gates by sequentially stacking TFETs are proposed, respectively. The simulation results of voltage transfer characteristics of the proposed M3D logic gates are investigated using mixed-mode simulator of technology computer aided design (TCAD), and the operation of each logic circuit is verified. The cell area for each M3D logic gate is reduced by about 50% compared to one for the two-dimensional planar logic gates.

A modification of the rip current warning system utilizing real-time observations: a database function of likelihood distributions (실시간 관측정보를 이용한 이안류 경보체계 개선 연구: 발생정도 DB함수의 활용)

  • Choi, Junwoo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.10
    • /
    • pp.843-854
    • /
    • 2022
  • For the rip current warning system to reduce rip-current accidents, the implementation method producing the risk index was modified. To produce fast response from the warning system based on real-time observations, the method employed the numerical results (i.e., rip current likelihoods according to the possible scenario) obtained in advance. In this study, instead of using the empirical curve-fitting functions of the previous method, the present modification utilized two-dimensional distributions (i.e., wave height and period, wave height and tidal elevation, wave height and direction, wave height and spreading of frequency-directional spectrum) of rip current likelihoods stacked in a database of the system. The wave and tidal observations in 2021 at the Haeundae coast were applied to the modified system, and its performances at several real events recorded in CCTV images were presented.

In Vivo and Ex Vivo Skin Reactions after Multiple Pulses of 1,064-nm, Microlens Array-type, Picosecond Laser Treatment

  • Lyu, Herin;Park, Jinyoung;Lee, Hee Chul;Lee, Sang Ju;Kim, Young Koo;Cho, Sung Bin
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.142-149
    • /
    • 2020
  • Background and Objectives A picosecond-domain laser treatment using a microlens array (MLA) or a diffractive optical element elicits therapeutic micro-injury zones in the skin. This study examined the patterns of tissue reactions after delivering multiple pulses of 1,064-nm, MLA-type, picosecond neodymium:yttrium-aluminum-garnet laser treatment. Materials and Methods Multiple pulses of picosecond laser treatment were delivered to ex vivo human or brown micropig skin and analyzed histopathologically. A high-speed cinematographic study was performed to visualize the multiple pulses of picosecond laser energy-induced skin reactions in in vivo human skin. Results In the ex vivo human skin, a picosecond laser treatment at a fluence of 0.3 J/cm2 over 100 non-stacking passes generated multiple lesions of thermally-initiated laser-induced optical breakdown (TI-LIOB) in the epidermis and dermis. In the ex vivo micropig skin, stacking pulses of 20, 40, 60, 80, and 100 at a fluence of 0.3 J/cm2 generated distinct round to oval zones of tissue coagulation in the mid to lower dermis. High-speed cinematography captured various patterns of twinkling, micro-spot reactions on the skin surface over 100 stacked pulses of a picosecond laser treatment. Conclusion Multiple pulses of 1,064-nm, MLA-type, picosecond laser treatment elicit marked TI-LIOB reactions in the epidermis and areas of round to oval thermal coagulation in the mid to deep dermis.

Detection of Landfast Sea Ice Near Jang Bogo Antarctic Research Station Using Layer-Stacked Sentinel-1 Interferometric SAR Coherence Images (Sentinel-1 영상레이더 간섭 긴밀도 영상의 레이어 병합을 활용한 남극 장보고 과학기지 주변 정착해빙 탐지)

  • Kim, Seung Hee;Han, Hyangsun
    • The Journal of Engineering Geology
    • /
    • v.32 no.2
    • /
    • pp.271-280
    • /
    • 2022
  • Landfast sea ice forms near coastlines in polar regions. Continuous monitoring of this sea ice is important, as it plays a key role in the marine ecosystem and affects the operation of nearby research stations. This study detected landfast sea ice around Jang Bogo research station in East Antarctica by stacking interferometric coherence images of Sentinel-1 synthetic aperture radar (SAR) data with 6-, 12- and 18-day temporal baselines. A total of 50 landfast sea ice maps were generated covering July 2017 to June 2018. The time series revealed regional differences in the timing of the maximum extent as well as growth rate of landfast sea ice. Overall, detecting landfast sea ice using interferometric SAR coherence seems promisingly feasible; however, limitations remain owing to low backscattering coefficients from new and smooth sea ice surfaces and subtle movements of sea ice in contact with the Campbell Glacier Tongue.

Revision Volume of Square-inch-spoon, Jeon-bi and Firmiana-Seed-sized Pill Preparations in 『Treatise on Cold Damage Diseases』 (『상한론』에서 산제의 방촌비와 전비, 환제의 오동자대 크기 수정치)

  • Kim, In-Rak
    • The Korea Journal of Herbology
    • /
    • v.37 no.5
    • /
    • pp.75-81
    • /
    • 2022
  • Objectives : In 『Treatise on Cold Damage Diseases』, the volume of preparation dosage measured in Hap was 6.5mL. This study aimed to confirm that a square-inch-spoon, which measures powder preparation dosage, was 1/3 Hap, and that Jeon-bi was 1/8 square-inch-spoon. Based on these values, this study also aimed to adjust the diameter of Firmiana-Seed-sized pill preparation, currently known as 6.5mm, so that one square-inch-spoon of powder preparation creates 16 pills. Methods : Calculated the ratio between the floor areas of square-inch-spoon and Jeon-bi and measured the ratio of volume; assumed that powder preparations were stacked as much as possible in the shape of a square pyramid when scooped comfortably, then calculated the slopes of 1/3 Hap and 1/4 Hap; measured the volumes of powdered Oryeongsan and Lijungwhan in square-inch-spoon and Jeon-bi; created the powders into Firmiana-Seed-sized pill preparation; adjusted the diameter of Firmiana Seed so that 16 pills could be created. Results : Inferring from the floor areas, the volume of square-inch-spoon is 9.2 times that of Jeon-bi; one square-inch-spoon should be 1/3 Hap for the powder to reach its maximum slope of 47° and, according to actual measurement of powder preparations, reach its maximum volume; when created into Firmiana-Seed-sized pill preparations, one square-inch-spoon should be 1/3 Hap so that approximately 16 pills were created. Conclusions : One square-inch-spoon of powder preparation was 1/3 Hap(2.17mL), Jeon-bi was 1/8 square-inch-spoon(0.27mL), and the diameter of Firmiana-Seed-sized pill preparation was 5.5mm.

Ultastructural Characteristics of Necrosis and Stunt Disease in Red Pepper by the Mixed Infections of Tobacco mosaic virus or Pepper mild mottle virus and Pepper mottle virus.

  • Kim, Dae. Hyun.;Kim, Jeong. Soo.;Kim, Jae. Hyun.;Eui. Kyoo. Cho
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.137.2-138
    • /
    • 2003
  • The commercial cultivars of red pepper were screened against Tobacco mosaic virus (TMV), Pepper mild mottle virus (PMMoV) and Pepper mottle virus (PepMoV) by seedling test. Tn single infection of TMV or PMMoV, mosaic symptom was produced on the cultivars of 'Cheongyang'and 'Wangshilgun'. However, in cultivars of 'Manilla'and 'Bugang', symptoms were not occurred. In single infection of PepMoV, symptoms of mottle and malformation were produced on the tested cultivars of 'Manilla', 'Bugang', 'Cheongyang'and 'Wangshilgun' In the cultivars of 'Cheongyang'and 'Wangshilgun', synergistic symptoms of stunt and lethal death were induced by mixed infections in the two combinations of TMV+PepMoV and PMMoV+PepMoV. However, in cultivars of 'Manilla'and 'Bugang', synergistic symptom was not occurred as mottle which was milder than that of single infection. Cells were single infected with TMV and PMMoV the cultivars of 'Cheongyang'and 'Wangshilgun', respectively, had typical ultrastructures of tobamovirus as the stacked-band structure and multiple spiral aggregate (SA). Ultrastructures of cell and tissues infected with PepMoV on the cultivars of 'Cheongyang', 'Wangshilgun', 'Manilla'and 'Bugang', the potyvirus inclusions of pinwhills, scrolls, lamminated aggregates and amorphous inclusion were observed. Infected cells with a combination of TMV+PepMoV and PMMoV+PepMoV, the virus particles and inclusions of the two different viruses were found only mixed infection in the same cytoplasm and the amounts of viruses in mixed infections were abundant than in single infection. The angled-layer aggregates (ALA) was observed in the cells infected mixedly with TMV and PepMoV

  • PDF

Surface treatment of silver-paste electrode by atmospheric-pressure plasma-jet (대기압 플라즈마 제트를 이용한 실버페이스트 전극의 표면처리)

  • Sheik Abdur Rahman;Shenawar Ali Khan;Yunsook Yang;Woo Young Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Silver paste is a valuable electrode material for electronic device applications because it is easy to handle with relatively low heat treatment. This study treated the electrode surface using an atmospheric-pressure plasma jet on the silver-paste electrode. This plasma jet was generated in an argon atmosphere using a high voltage of 5.5 to 6.5 kV with an operating frequency of 11.5 kHz. Plasma-jet may be more beneficial to the printing process by performing it at atmospheric pressure. The electrode surface becomes hydrophilic quickly and contact angle variation is observed on the electrode surface as a function of plasma treatment time, applied voltage, and gas flow rate. Also, there was no deviation in the contact angle after the plasma treatment in the large-area sample, that means a uniform result could be obtained regardless of the substrate size. The outcomes of this study are expected to be very useful in forming a stacked structure in the manufacture of large-area electronic devices and future applications.

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

A Study on Floor Impact Sound Insulation Performance of Cross-Laminated Timber (CLT): Focused on Joint Types, Species and Thicknesses

  • Yeon-Su HA;Hyo-Jin LEE;Sang-Joon LEE;Jin-Ae SHIN;Da-Bin SONG
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.5
    • /
    • pp.419-430
    • /
    • 2023
  • In this study, the floor impact sound insulation performance of Korean domestic Cross-Laminated Timber (CLT) slabs was evaluated according to their joint types, species and thicknesses in laboratory experiments. The sound insulation performance of the CLT has not been investigated before, thus, this study was conducted to quantify basic data on floor impact sound insulation performance of CLT slabs. 5-ply and 150 mm thick CLT panels made of 2 species, Larix kaempferi and Pinus densiflora, were used for the study. The CLT panels were assembled by 3 types of inter-panel joints to form floor slabs: spline, butt and half-lap. And the 150 mm thick Larix CLT slabs were stacked to the thicknesses of 300 mm and 450 mm. The heavy-weight floor impact sound insulation performance of the 150 mm CLT slabs were evaluated to be 70 dB for the Larix slabs and 71.6 dB for the Pinus slabs, and the light-weight floor impact sound insulation performance, 78.3 dB and 79.6 dB, respectively. No significant difference in the sound insulation performance was found between the slabs of the 2 species or among the 3 types of joints. The reduction of 1 dB in the heavy-weight floor impact sound and 1.6 dB in the light-weight floor impact sound per 30 mm increase in thickness were confirmed through the experiments. This study can be viewed as the basic research for the evaluation of floor impact sound insulation performance of CLT.