• Title/Summary/Keyword: stack effect

Search Result 324, Processing Time 0.033 seconds

Evaluation of Reverse Electrodialysis based on the Number of Cell Pairs and Stack Size Using Patterned Ion Exchange Membrane (패턴형 이온교환막을 이용한 스택의 셀 수 및 크기에 따른 역전기투석 성능 평가)

  • Dong-Gun Lee;Hanki Kim;Namjo Jeong;Young Sun Mok;Jiyeon Choi
    • New & Renewable Energy
    • /
    • v.19 no.2
    • /
    • pp.31-39
    • /
    • 2023
  • Salinity gradient energy can be generated from a mixture of water streams with different salt concentrations by using reverse electrodialysis (RED). In this study, we evaluated the effect of stack size and number of cell pairs on the energy efficiency and specific energy of the RED process. Additionally, we studied the prementioned parameters to maximize the power density of RED. The performance of the RED stack which used a patterned ion exchange membrane, was evaluated as a function of stack size and feed flow rate. Moreover, it was noted that an increase in stack size increased the ion movement through the ion exchange membrane. Furthermore, an increase in feed flow rate led to a reduction in the concentration variation, resulting in an increase in OCV and power density. The energy efficiency and specific energy for 100 cells in the 10 × 10 cm2 stack were the highest at 12% and 0.05 kWh/m3, respectively, while the power density from 0.33 cm/s to 5 × 5 cm2 stack was the highest at 0.53 W/m2. The study showed that the RED performance can be improved by altering the size of the stack and the number of cell pairs, thereby positively affecting energy efficiency and specific energy.

Design of Multi-stack Axial Flux Permanent Magnet Synchronous Generator Considering Electromagnetic and Mechanical Characteristics (전자기 및 기계적 특성을 고려한 다중 적층형 AFPMSG의 설계)

  • Syed, Qurban Ali Shah;You, Young-Min;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1043-1044
    • /
    • 2011
  • This paper discusses the electromagnetic and mechanical design considerations to improve the design accuracy and power to mass ratio of multi-stack axial flux permanent magnet synchronous generator (AFPMSG). Design accuracy of multi-stack AFPMSG for direct drive wind turbine application is improved by considering magnetic flux leakages and fringing effect. FEM structural analysis is utilized to increase power to mass ratio of three-stack AFPMSG by reducing the rotor yoke thickness considering magnetic and centrifugal forces and Von Mises stress distribution.

  • PDF

Analytical Study on the Oscillating Flow Effect in a Anode Channel of Direct Methanol Fuel Cells (연료극 왕복유동이 직접 메탄올 연료전지에 미치는 영향에 대한 해석적 연구)

  • Hwang, Yong-Sheen;Lee, Dae-Young;Kim, Seo-Young;Choi, Hoon;Cha, Suk-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.27-30
    • /
    • 2007
  • This study considers the feasibility of the concentration control of the methanol solution by oscillating flow in the anode channel of passive type Direct Methanol Fuel Cells(DMFC). DMFC stack performance is largely influenced by the fuel concentration. If the fuel concentration is either lower than 0.5M or more than 2M, its performance deteriorates seriously because of the fuel starvation or the fuel crossover. In this respect the optimization of the fuel concentration is crucially important to maximize the DMFC stack performance. In this work, the effects of oscillating actuation in the fuel supply are studied to control the fuel concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the DMFC stack.

  • PDF

Development of Outdoor 50W-LED Module using Heat-pipe and Stack-fin (히트파이프 및 스택핀을 이용한 50W급 옥외용 LED 모듈개발)

  • Hong, Seok-Gi;Jeong, Hee-Suk;Ryeom, Jeong-duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.15-21
    • /
    • 2015
  • We proposed 50W-LED modules of using Heat-pipe and Stack-fin and produced LED modules was evaluated heat dissipation characteristics with comparison of the conventional die-casting type. It verified the application of products by applying it to 150W-LED road luminaires through simulation. The LED module was measures aimed design temperature of the Stack-fin and showed 26% upward heat dissipation effect than a conventional die-casting type. The luminous efficacy of 150W-LED road luminaires using this LED module reached over 112lm/W, and the simulation results showed average of horizontal luminance, overall luminance uniformity($U_O$) and lane luminance uniformity($U_I$) that is suitable for five-lane road with the KS standards.

Constitution and Operation of the 25 kW Molten Carbonate Fuel Cell Power Generation System for Power Utility (25 kW급 전력사업용 MCFC 발전시스템 구성 및 운전평가)

  • Lim, Hee-Chun;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.687-689
    • /
    • 2000
  • Molten Carbonate Fuel Cell (MCFC) with high electrical efficiency and low environmental effect has been developed for the commercial application of power generation fields. Recently we have built a 25 kW molten carbonate fuel cell power generation system and tested it. The MCFC system is composed of diverse peripheral units such as reformer, pre-heater, water purifier. electrical loader, gas supplier, and recycling systems. The stack itself was made of 40 cells of $6.000 cm^2$ area each. The stack showed an output of 28.6 kW power and a reliable performance at atmospheric operation. while in pressurized operation the stack showed an output 25.6 kW lower than the atmospheric operation. The reason of lower performance of pressurized operation was caused from a gas cross over shown in few cells in the stack.

  • PDF

Thermal Stress Analysis of a Fuel Cell Stack using an Orthotropic Material Model (복합재료 연료전지 스택의 열응력 해석)

  • Jeon Ji Hoon;Hwang Woonbong;Um Sukkee;Kim Soowhan;Lim Tae Won
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.206-209
    • /
    • 2004
  • Mechanical behavior of a fuel stack was studied using an orthotropic material model. The fuel stack is essentially composed of a bipolar plate (BP), a gasket, an end plate, a membrane electrolyte assembly (MEA), and a gas diffusion layer (GDL). Each component is fastened with a suitable pressure. It is important to maintain a suitable contact pressure distribution of BP, because it influences the power efficiency of the fuel cell stack. When it is exposed to high temperature, its behavior must be stable. Hence, we performed stress analysis at high temperature as well as at room temperature. At high temperature, the contact pressure distribution becomes poor. Many patents have shown that using an elastomer can overcome this phenomena. Its effect was also studied. By using an elastomer, we found a good contact pressure distribution at high temperature as well as at room temperature.

  • PDF

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Effect of Atmospheric Pressure Difference with Altitude on the Induced Airflow Velocity in a Vertical Closed Conduit (수직 공간 내에서 고도변화에 따른 기압차로 인한 기류현상 예측에 관한 연구)

  • Chung, Kwang-Seop;Kim, Chul-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.409-416
    • /
    • 2009
  • On 21st century, global warming is the most serious environmental problem threatening the existence of lives on the earth. One of the serious reasons of this nature phenomena was due to the greenhouse effect by carbon dioxide mainly produced with the combustion process of hydro-carbon fuel. and it is mostly produced. In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this research is on the obtaining of the renewable energy source in the skyscrape buildings in the metropolitan area. The air movement is happens due to the atmospheric pressure differences in the air. Due to this simple physical theory, it is easily expected to obtain the useful renewable nature energy through the high -raised vertical air stack installed in a tall building. However, there is one problem that should be resolved which is called air-hole effect in the sky -scrape buildings.

The Influence of Natural Smoke Ventilators and Wind Velocities on the Stack effect in High-rise Buildings (배연창 및 외기풍속이 초고층 건축물의 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Yeo, Yong-Ju;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.20-26
    • /
    • 2008
  • The performance of natural smoke ventilators in High-rise buildings was analyzed by investigating the stack effect depending on the wind velocities using CONTAMW tool. The results showed that the opening of smoke ventilators can influence on the stack effect in the building thus moving the position of the neutral plane toward the opened smoke ventilators. The outside wind velocities can move up the neutral plane toward the top of the building thus increasing pressure differentials at the bottom of the building. The smoke ventilators can maintain its normal performance without outside wind, however, strong outside wind can prevent natural smoke exhaust due to the infiltration of outside air at the ventilators.

A Web Based Secure E-Mail System Using the PGP Algorithm (PGP 방식을 이용한 웹 기반 전자우편 보안 시스템)

  • 박동욱;박재희;김진상;김일민
    • The KIPS Transactions:PartC
    • /
    • v.8C no.1
    • /
    • pp.16-22
    • /
    • 2001
  • There are several traditional factors of software quality. Some of them are such as correctness, reliability, efficiency, compatibility, portability, etc. In addition to them, security is required as another factor of software quality nowadays because some application programs are used as a way to attack information systems by stack frame manipulation. Each processor has its own peculiar stack frame mechanism and C language uses the characteristics of them. This paper explains the concept of security problem caused by stack frame manipulation, and the stack frame mechanism of Pentium, Alpha and SP ARC processor in detail. And then it examines the effect of stack frame mechanism on the security of programs in C language.

  • PDF